Skip Navigation



Europace Advance Access published online on July 28, 2008

Europace, doi:10.1093/europace/eun194
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/9/1060    most recent
eun194v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Theuns, D. A.M.J.
Right arrow Articles by Jordaens, L. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Theuns, D. A.M.J.
Right arrow Articles by Jordaens, L. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org

Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates

Dominic A.M.J. Theuns1,*, Maximo Rivero-Ayerza1, Dick M. Goedhart2, Max Miltenburg1 and Luc J. Jordaens1

1 Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands; 2 Department of Statistics, Cardialysis, Rotterdam, The Netherlands

Background: Morphology discrimination (MD) in implantable cardioverter-defibrillators (ICDs) is based on the comparison of the ventricular electrogram during tachycardia with a stored reference template obtained during baseline rhythm. However, the effect of heart rate on the template match percentage during supraventricular tachyarrhythmias (SVT) is not known. The purpose of this study was to evaluate the performance of the template match percentage during SVT at different heart rates.

Methods and results: Stored electrograms of 868 tachyarrhythmias from 88 patients with a dual-chamber ICD (St Jude Medical, USA) were analysed by the investigators. The effect of heart rate on template match percentage was estimated by regression analysis. For performance measures, data were corrected for multiple episodes in a patient by using the generalized estimating equation method. The mean template match percentage was 86.6 ± 22.2% (median 100%) for SVT episodes. No significant differences in template match percentage between fast [ventricular cycle length (CL) 300–350 ms] and slow (ventricular CL >400 ms) SVTs were observed (85.4 ± 27.0 vs. 87.1 ± 19.7%). Using nominal settings, MD alone provided sensitivity and specificity of 70.2% and 89.4% overall, respectively. Morphology discrimination in conjunction with rate branch analysis, sudden onset, and stability yielded sensitivity and specificity of 98.5% and 91.2%, respectively.

Conclusion: Morphology discrimination has a consistently high template match percentage during SVTs, which is independent of ventricular CL. The consistent high match percentage results in high specificity for arrhythmia discrimination.

Key Words: Implantable cardioverter-defibrillator, Arrhythmias, Atrial fibrillation, Morphology, Electrogram


* Corresponding author: Department of Clinical Electrophysiology, Erasmus MC, Bd416, Molewaterplein 40, PO Box 2040, 3000 CA Rotterdam, The Netherlands. Tel: +31 10 703 2938; fax: +31 10 703 4420. E-mail address: d.theuns{at}erasmusmc.nl

Manuscript submitted 2 May 2008. Accepted after revision 9 July 2008.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
J. Toquero, J. Alzueta, L. Mont, I. F. Lozano, A. Barrera, A. Berruezo, V. Castro, J. L. Pena, M. L. Fidalgo, and J. Brugada
Morphology discrimination criterion wavelet improves rhythm discrimination in single-chamber implantable cardioverter-defibrillators: Spanish Register of morphology discrimination criterion wavelet (REMEDIO)
Europace, June 1, 2009; 11(6): 727 - 733.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. C. Gronefeld
Discrimination of ventricular tachycardia from supraventricular tachycardia in implantable cardioverter defibrillators by automated electrogram morphology analysis: can leads finally replace the electrophysiologist?
Europace, October 1, 2008; 10(10): 1131 - 1132.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.