Skip Navigation



Europace Advance Access published online on January 16, 2008

Europace, doi:10.1093/europace/eum289
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/2/164    most recent
eum289v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ricci, R. P.
Right arrow Articles by Santini, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ricci, R. P.
Right arrow Articles by Santini, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2007. For permissions please email: journals.permissions@oxfordjournals.org

Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization

Renato Pietro Ricci*, Loredana Morichelli and Massimo Santini

Department of Cardiovascular Disease, San Filippo Neri Hospital, Via Martinotti 20, 00135 Rome, Italy

Aims: To evaluate the impact of Home MonitoringTM(HM) remote control on patient medical treatment and on health-care resource utilization.

Methods and results: One hundred and seventeen patients received HM pacemakers or defibrillators. A pacing expert nurse consulted daily the website and submitted critical cases to physician. During a mean follow-up of 227 ± 128 days, 25 210 messages were received (23 545 daily messages and 1665 alert events) resulting in 90.7% of HM supervised days. Fifty-nine minutes/week for the nurse and 12 min/week for the physician were spent for HM data analysis during 267 web-connections. The mean connection time per patient was 115 ± 60 s. The nurse submitted to the physician 133 critical cases in 56 patients. The diagnosis were atrial fibrillation (47%), ventricular tachyarrhythmias (9%), inappropriate implantable cardioverter defibrillator intervention (4%), unsustained ventricular tachycardia (7%), device suboptimal programming (23%), and impending heart failure (10%). Sixty-six unplanned follow-up in 43 patients led to drug therapy change (44%), device reprogramming (18%), diagnosis confirmation without further intervention (24%), no confirmation (6%), further diagnostic tests (9%).

Conclusion: HM technology allowed optimization of medical treatment and device programming with low consumption of health-care resource.

Key Words: Home monitoring, Telecardiology, Atrial fibrillation, Ventricular tachyarrhythmias, Heart failure, Cardiac pacing


* Corresponding author. Tel: +39 06 3306 3934; fax: +39 06 3306 2489.E-mail address: renatopietroricci{at}tin.it

Manuscript submitted 18 September 2007. Accepted after revision 10 December 2007.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
G. Boriani, M. Biffi, C. Martignani, C. Valzania, I. Diemberger, M. Bertini, G. Domenichini, M. Ziacchi, and A. Branzi
Is cardiac resynchronization therapy cost-effective?
Europace, November 1, 2009; 11(suppl_5): v93 - v97.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Andrikopoulos, S. Tzeis, G. Theodorakis, and P. Vardas
Monitoring capabilities of cardiac rhythm management devices
Europace, October 29, 2009; (2009) eup317v1.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. N. Simantirakis, E. G. Arkolaki, and P. E. Vardas
Novel pacing algorithms: do they represent a beneficial proposition for patients, physicians, and the health care system?
Europace, October 1, 2009; 11(10): 1272 - 1280.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
R. P. Ricci
Automatic left ventricular pacing management: not only a technical step up
Europace, July 1, 2009; 11(7): 848 - 849.
[Full Text] [PDF]


Home page
EuropaceHome page
H. Burri and D. Senouf
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
Europace, June 1, 2009; 11(6): 701 - 709.
[Abstract] [Full Text] [PDF]


Home page
BMJ Case ReportsHome page
M. A. Mercader and Y. Bader
Internet diagnosis of digitalis toxicity
BMJ Case Reports, April 7, 2009; 2009(apr07_1): bcr0920080918 - bcr0920080918.
[Abstract] [Full Text]


Home page
EuropaceHome page
S. Spencker, N. Coban, L. Koch, A. Schirdewan, and D. Muller
Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
Europace, April 1, 2009; 11(4): 483 - 488.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. Sacher, V. Probst, M. Bessouet, M. Wright, A. Maluski, S. Abbey, P. Bordachar, A. Deplagne, S. Ploux, G. Lande, et al.
Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population
Europace, April 1, 2009; 11(4): 489 - 494.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
R. P. Ricci, L. Morichelli, and M. Santini
Remote control of implanted devices through Home MonitoringTM technology improves detection and clinical management of atrial fibrillation
Europace, January 1, 2009; 11(1): 54 - 61.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. Halimi, J. Clementy, P. Attuel, X. Dessenne, W. Amara, and on behalf of the OEDIPE trial Investigators
Optimized post-operative surveillance of permanent pacemakers by home monitoring: the OEDIPE trial
Europace, December 1, 2008; 10(12): 1392 - 1399.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.