Skip Navigation



Europace Advance Access published online on October 2, 2007

Europace, doi:10.1093/europace/eum126
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
9/12/1144    most recent
eum126v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Bänsch, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bänsch, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2007. All rights reserved. For permissions, please e-mail: journals.permissions@oxfordjournals.org

The quick-implantable-defibrillator trial

Dietmar Bänsch1,*, Hans Kottkamp2, Gerian Grönefeld3, Jürgen Vogt4, Carsten Israel3, Dirk Böcker5, Gerd Hindricks2, Karl-Heinz Kuck on behalf of the Quick-ICD investigators1

1 Department of Cardiology, St. Georg's Hospital, Hamburg, Germany; 2 Heart Centre, University Clinic, Leipzig, Germany; 3 Department of Cardiology, J-W-Goethe University, Frankfurt, Germany; 4 Herz- und Diabeteszentrum NRW, Bad Oeynhausen, Germany; 5 Department of Cardiology and Angiology, Westfaelische Wilhelms-University, Muenster, Germany

Aims Earlier ICD therapy included an electrophysiological study (EPS), an extensive defibrillation threshold test (DFT), and a pre-discharge test. Now that ICD-therapy is widely accepted, an EPS is no longer performed in most patients, extensive DFT-tests have been reduced to a minimum of two effective shocks and discharge tests have been discarded in most centres. However, it has never been demonstrated prospectively that this simplification is safe.

Methods and results The Quick-Implantable-Defibrillator (Quick-ICD) Trial was a prospective multi-centre trial, which randomized patients, who had survived a cardiac arrest (SCD) or an unstable ventricular tachycardia (VT), to two different clinical strategies:(a) The extensive strategy included an EPS, an extensive DFT-test, and a pre-discharge test; (b) In the simplified approach (quick strategy) the ICD was implanted without an EPS and a pre-discharge test. Two effective shocks during implantation at 21 J were sufficient. The primary endpoint of this trial was a cluster of adverse events related to the diagnostic approach and to ICD-therapy. One hundred and ninety patients were included, 97 randomized to the extensive-, 93 to the quick strategy. Mean follow-up was 12 ± 7 months. Twenty-seven patients reached the endpoint in the quick group and 32 in the extensive group. During follow-up, the event-free survival was equal in the two study arms (test for equivalence, P = 0.0044). The initial hospital stay was significantly shorter in the quick population (8.4 ± 4.7 vs. 11.2 ± 7.4 days, P = 0.004)

Conclusion It is safe and cost-effective to implant an ICD without an EPS, an extensive DFT-, and a pre-discharge test in carefully selected patients after survived SCD or unstable VTs.

Key Words: Implantable cardioverter defibrillator, Programmed ventricular stimulation, Defibrillation threshold testing, DFT, ICD


* Corresponding author. Tel: +49 40 2890 2305/4488; fax: +49 40 2890 4435. E-mail address: dietmarbaensch{at}alice-dsl.de

Manuscript submitted 26 April 2007. Accepted after revision 7 June 2007.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.