Skip Navigation



Europace Advance Access published online on June 26, 2007

Europace, doi:10.1093/europace/eum123
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
9/8/657    most recent
eum123v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Küpper, B.
Right arrow Articles by Heuer, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Küpper, B.
Right arrow Articles by Heuer, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Do small (6.6 Fr.) active and passive fixation defibrillation leads perform as well as larger sized leads? a multi-centre analysis

Bernhard Küpper1,*, Raymond Yee2, Gilles O'Hara3, Chris S. Simpson4, Paolo Della Bella5, Martin Workel6, Michael Hull7 and H. Heuer8

1 Schüchtermann Klinik, Bad Rothenfelde, Germany; 2 London Health Sciences Centre, London, Ontario, Canada; 3 Hôpital Laval, Sainte-Foy, Québec, Canada; 4 Kingston General Hospital, Kingston, Ontario, Canada; 5 Centro Cardiologico Monzino, Milan, Italy; 6 Medtronic, Bakken Research Center BV, Maastricht, The, Netherlands; 7 Medtronic Inc., Minneapolis, MN, USA; 8 St. Johannes Hospital, Dortmund, Germany

Aims The 6.6 Fr. Sprint Fidelis® lead family may allow multiple lead implantation procedures with reduced risk of venous obstruction.

Methods and results Two prospective, historically controlled, multi-centre studies were conducted in Europe (80 patients) and Canada (79 patients). The purpose was to assess the ventricular lead-related adverse events (LRAEs) and performance of the small Models 6948 and 6949 defibrillation leads, respectively, in patients with a standard indication for an ICD implant. Safety was assessed by demonstrating equivalence of the LRAE free rate at 1 month to comparable but larger leads (Models 6942, 6943, 6944, 6947and 4074). Seventy-five of 80 patients with a 6948 lead (93.8%) remained free of LRAEs. Seventy-four out of 79 patients (93.7%) with the 6949 lead remained free of LRAEs. The 95% lower confidence bounds were above the critical difference limits. Thus, safety of the Sprint Fidelis® leads is similar to that of larger leads. Electrical performance through 1-month follow-up proved to be acceptable in comparison with other established leads.

Conclusion These multi-centre studies confirm that smaller defibrillation leads offer similar safety and efficacy features to widely used larger leads; they have low LRAE rates and defibrillation thresholds, while providing the advantage of a smaller introducer size and reduced venous obstruction.

Key Words: Defibrillation lead, Dual coil, ICD, Lead handling, Safety, Electrical performance


* Corresponding author: Abteilung Kardiologie/Angiologie, Elisabeth-Krankenhaus, Klara-Kopp-Weg 1, D-45138 Essen, Germany. Tel: +49 201 897 3201; fax: +49 201 288 525. E-mail address: b.kuepper{at}elisabeth-essen.de

Manuscript submitted 12 December 2006. Accepted after revision 24 May 2007.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Circ Arrhythm ElectrophysiolHome page
C. J. W. Borleffs, L. van Erven, R. J. van Bommel, E. T. van der Velde, E. E. van der Wall, J. J. Bax, F. R. Rosendaal, and M. J. Schalij
Risk of Failure of Transvenous Implantable Cardioverter-Defibrillator Leads
Circ Arrhythm Electrophysiol, August 1, 2009; 2(4): 411 - 416.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.