Skip Navigation



Europace Advance Access published online on May 3, 2007

Europace, doi:10.1093/europace/eum066
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
9/8/687    most recent
eum066v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Page, E.
Right arrow Articles by Casset, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Page, E.
Right arrow Articles by Casset, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org

Physiological approach to monitor patients in congestive heart failure: application of a new implantable device-based system to monitor daily life activity and ventilation

Eric Page1,*, Serge Cazeau2, Philippe Ritter2, Daniel Galley3 and Cyrille Casset4

1 UCPX, Laboratoire de physiopathologie de l'exercice, Grenoble, France; 2 InParys, Saint-Cloud, France; 3 Centre Hospitalier Général, Albi, France; 4 ELA Medical, Sorin group, Le Plessis-Robinson, France

Aims We examine an expert system designed to permanently monitor patients with congestive heart failure (CHF) using data of a dual-sensor pacemaker and to allow warning of significant changes in physiological indices.

Methods and results This study included 67 implanted patients divided into two groups: a control group without history of CHF (n = 19) who had received DDDR pacemakers (DDD group) and a test group (n = 48) who had received cardiac resynchronization therapy systems (CRT group) for severe CHF (NYHA III or IV, LVEF <40%). The embedded monitoring system measures minute ventilation (MV) and activity (ACT) at rest and at exercise. All devices collect data, and all adverse medical events were recorded. Data are stored daily for up to 3 months. The mean ACT was similar for both groups. Mean rest and exercise MV were significantly higher in CRT group. On 195 periods of 1-month follow-up in the CRT group, 31 events were suspected, 22 were true positive, 9 were false-positive, and 3 clinical adverse events were not predicted (sensitivity: 88%, specificity: 94.7%, positive predictive value: 71%, negative predictive value: 98.2%)

Conclusion A new diagnostic expert system that holds promise for the long-term ambulatory monitoring of CHF was developed.

Key Words: Heart failure, Cardiac pacing, Exercise


* Corresponding author. Tel: +33 476 29 1773; Fax: +33 476 33 8469. E-mail address: ericpagecardio{at}wanadoo.fr

Manuscript submitted 9 February 2007. Accepted after revision 19 March 2007.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.