Skip Navigation



Europace Advance Access published online on June 7, 2006

Europace, doi:10.1093/europace/eul050
This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
8/7/512    most recent
eul050v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Siaplaouras, S.
Right arrow Articles by Mewis, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Siaplaouras, S.
Right arrow Articles by Mewis, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2006. All rights reserved
Received October 25, 2005
Accepted March 18, 2006


Article

Remote detection of incessant slow VT with an ICD capable of home monitoring

Stephanos Siaplaouras 1 *, Axel Buob 1, Hans Ruprecht Neuberger 1, and Christian Mewis 1

1 Klinik für Innere Medizin III (Kardiologie, Angiologie und Internistische Intensivmedizin) Universitätsklinikum des Saarlandes, Kirrberger Strasse, D-66421 Homburg/Saar, Germany

* To whom correspondence should be addressed.
Stephanos Siaplaouras, E-mail: siaplaouras{at}aol.com


   Abstract

In this case report, we present a 57-year-old patient who suffered from incessant slow ventricular tachycardia because of a change in therapy 2 weeks after the implantation of an implantable cardioverter defibrillator (ICD) with Home Monitoring (HM). HM is a fully automatic and wireless system capable of transmitting device data including episode counters. The patient had mild symptoms with only short episodes of dizziness and would not have contacted the primary care centre. Due to HM, the arrhythmia was detected before the next routine follow-up, and the patient was seen the next day. HM made it possible to adjust the dosage of the newly established beta-blocker treatment in an outpatient setting and avoid hospitalization. HM yields the potential for remote detection of arrhythmias in ICD recipients, allowing alterations in device programming or medication.

Keywords: Home Monitoring; ICD.
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
G. Andrikopoulos, S. Tzeis, G. Theodorakis, and P. Vardas
Monitoring capabilities of cardiac rhythm management devices
Europace, October 29, 2009; (2009) eup317v1.
[Abstract] [Full Text] [PDF]


Home page
J Telemed TelecareHome page
C. Masella, P. Zanaboni, F. Di Stasi, S. Gilardi, P. Ponzi, and S. Valsecchi
Assessment of a remote monitoring system for implantable cardioverter defibrillators
J Telemed Telecare, September 1, 2008; 14(6): 290 - 294.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
H. Heidbuchel, P. Lioen, S. Foulon, W. Huybrechts, J. Ector, R. Willems, and H. Ector
Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator
Europace, March 1, 2008; 10(3): 351 - 357.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.