Skip Navigation

Europace 2002 4(4):427-430; doi:10.1053/eupc.2002.0263
© 2002 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Zaim, S.
Right arrow Articles by Huehn, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zaim, S.
Right arrow Articles by Huehn, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


CASE REPORT

Inappropriate high-rate ventricular pacing in a patient with a defibrillator

S. Zaim1, H. Sunthorn1, J.-J. Adatte1, K. Kürsteiner1, D. Burgener2 and C. Huehn2

1Division of Cardiology, University Hospital of Geneva Geneva, Switzerland; 2Department of Medicine, University Hospital of Geneva Geneva, Switzerland

We describe a patient who presented with high rate ventricular pacing secondary to dysfunction of his implantable cardioverter defibrillator (ICD). The device was also unable to communicate with the programmer and unable to treat ventricular fibrillation. Immediate disconnection of the ICD from the leads was the only effective recourse. Subsequent detailed technical analysis of the device revealed a different electrical circuit problem from that found in typical cases of runaway pacing. To our knowledge this is the first description of a malfunction of precisely this nature.

Key Words: High rate pacing, runaway pacemaker, ICD, malfunction


Correspondence: Sina Zaim, MD, Division of Cardiology, New Jersey Medical School, 185 S. Orange Avenue, Newark, NJ, 07103-2714, USA. Tel: (001) 973-972-1969; fax: (001) 973-972-1969; email: szaimmd{at}hotmail.com


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.