Europace Advance Access originally published online on April 7, 2008
Europace 2008 10(5):528-535; doi:10.1093/europace/eun072
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ICDs
Dual-chamber defibrillators reduce clinically significant adverse events compared with single-chamber devices: results from the DATAS (Dual chamber and Atrial Tachyarrhythmias Adverse events Study) trial
1 Cardiology Department, Hospital General Universitario Gregorio Maranon, Madrid, Spain; 2 Cardiology Department, Hospital Universitario 12 de Octubre, Madrid, Spain; 3 Cardiology Department, University Hospital of Mannheim, Mannheim, Germany; 4 Heart Diseases Department, Hospital San Filippo Neri, Roma, Italy; 5 Cardiology Department, Hospital Santa Cruz, Carnaxide, Portugal; 6 Estadistica e Investigacion Operativa, Universitat Politecnica de Catalunya, Barcelona, Spain; 7 Scientific and Clinical Department, Medtronic Iberica, Barcelona, Spain; 8 Cardiology Department, Hospital General Universitario de Valencia, Valencia, Spain
Aims: This randomized trial evaluated clinically significant adverse events (CSAEs), in patients implanted with dual-chamber (DC) vs. single-chamber (SC) implantable cardioverter defibrillator (ICD). DC-ICD had atrial tachyarrhythmia (AT) therapy capabilities. Strict programming recommendations were reinforced.
Methods and results: Patients with conventional SC-ICD indication were randomized to DC-ICD, SC-ICD, or a DC-ICD programmed as an SC-ICD (SC-simulated) and followed for 16 months. Patients in the DC and SC-simulated groups crossed over after 8 months. The primary endpoint was a composite of CSAE: all-cause mortality; invasive intervention; hospitalization (>24 h) for cardiovascular causes; inappropriate shocks (two or more episodes); and sustained symptomatic AT lasting >48 h. The outcome variable was a pre-specified score that corrected for clinical severity and follow-up duration. Three hundred and thirty-four patients were analysed (DC-ICD, n = 112; SC-ICD, n = 111; SC-simulated, n = 111). The mean left ventricular ejection fraction was 0.36 ± 0.13, 69% were in functional class
II. CSAE occurred in 65 DC-ICD, 82 SC-ICD, and 84 SC-simulated patients. The outcome variable was 33% lower in the DC-ICD group (OR 0.31; 95% CI 0.14–0.67; P = 0.0028). Mortality was 4% in DC, 9% in SC, and 10% in SC-simulated.
Conclusion: In patients with a standard SC-ICD indication, DC-ICD was associated with less CSAE when compared with SC-ICD.
Key Words: Defibrillation, Tachyarrhythmias, Pacing
* Corresponding author: Servicio de Cardiologia (Planta 5), Hospital Gregorio Marañon, Doctor Esquerdo, 46, 28007 Madrid, Spain. Tel: +34 915868281; fax: +34 915868018.E-mail address: almendral{at}secardiologia.es
Manuscript submitted 8 December 2007. Accepted after revision 22 February 2008.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
Z. Vardanyan and B. Kanna Data analysis and interpretation of results in DATAS trial Europace, October 1, 2008; 10(10): 1243 - 1243. [Full Text] [PDF] |
||||