Skip Navigation

Europace 2008 10(2):156-160; doi:10.1093/europace/eum278
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Mazzetti, H.
Right arrow Articles by Mascheroni, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mazzetti, H.
Right arrow Articles by Mascheroni, O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org


PACING

Transjugular approach for lead extraction

Hector Mazzetti*, Carlos F. Cichero, M. Cristina Tentori and Osvaldo Mascheroni

Cardiology Division, Hospital Juan A. Fernández, Cerviño 3356, CP 1425 Buenos Aires, Argentina

Aims: The purpose of this manuscript is to describe a transjugular extraction technique which permits the use of locking stylets and sheaths, for leads previously cut and retracted into the venous system and/or damaged during an extraction performed via the superior approach.

Methods and results: A horizontal cervical incision is made over the sternocleidomastoid muscle to access the internal jugular vein between both fascicles of the muscle. The vein is ligated and through a phlebotomy a pig-tail catheter or the laparoscopic tool is introduced into the jugular vein. At the end of the procedure, a second ligature is also applied. This technique was utilized in 18 patients for the extraction of 22 leads with a mean implant duration of 91.8 months (range from 12 to 285 months). The age of the patients ranged from 19 to 87 years, (mean = 58.6 years). Out of the 22 leads extracted, 14 were ventricular pacemaker leads, 5 atrial pacemaker leads, 2 ICD leads, and 1 ventricular lead for VDD pacing. As regards the extractions, 18 were complete, 2 tips were abandoned (partial extractions), and 2 failed.

Conclusion: This technique is especially useful if the leads to be extracted were previously cut and had retracted into the central circulation. Although our experience is based only on 18 patients and 22 leads, we can conclude that the success rate we have achieved was high and the complication rate was very low.

Key Words: Lead extraction, Transjugular approach, Laparoscopic tools


* Corresponding author. Tel: +54 11 4241 4140; fax +54 11 4240 1071. E-mail address: hmazzetti{at}intramed.net.ar

Manuscript submitted 9 March 2007. Accepted after revision 25 November 2007.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
M.J. P. Raatikainen, J. Perala, and J. Lahtinen
Successful defibrillator lead remnant extraction from right ventricle using a steerable transseptal sheath and a basket retriever
Europace, September 1, 2009; 11(9): 1238 - 1240.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. Kennergren, C. Bjurman, R. Wiklund, and J. Gabel
A single-centre experience of over one thousand lead extractions
Europace, May 1, 2009; 11(5): 612 - 617.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.