Skip Navigation

Europace 1999 1(3):192-196; doi:10.1053/eupc.1999.0038
© 1999 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (3)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Ishikawa, T.
Right arrow Articles by Umemura, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ishikawa, T.
Right arrow Articles by Umemura, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Relationship between atrioventricular delay, QT interval and cardiac function in patients with implanted DDD pacemakers

T. Ishikawa, T. Sugano, S. Sumita, K. Kimura, M. Kikuchi, M. Kosuge, I. Kobayashi, T. Shigemasa, T. Endo, T. Usui and S. Umemura

Second Department of Internal Medicine, Yokohama City University Urafune Hospital Yokohama, Japan

QT interval may change when cardiac function is improved by optimizing the atrioventricular the (AV) delay. The relationship between AV delay, QT interval and cardiac function in patients with implanted DDD pacemakers was studied in 12 patients (aged 71 ± 12 SD years) with complete or high degree AV block. Cardiac output (CO) was measured using a Swan–Ganz catheter or by continuous Doppler echocardiography. The pacing rate was fixed at 70–80/min to eliminate the influence of heart rate. The AV delay was prolonged stepwise by 30 ms starting from 90 ms. All measurements were performed after 5 min of pacing. When the AV delay was prolonged, the CO and QT interval gradually increased and reached a peak, and then decreased. When the CO was increased from the minimum to the maximum value by optimizing the AV delay, the QT interval was significantly prolonged from 440 ± 40 to 456 ± 39 ms (P<0·002). The CO increased from 5·5 ± 2·5 to 6·0 ± 2·5 l·min–1 (P<0·002) when the AV delay was changed, during which the QT interval was prolonged from the minimum to the maximum value. There was a significant positive correlation between the optimal AV delay at which CO was maximal (161 ± 33 ms) and the optimal AV delay predicted from the maximum QT interval (167 ± 29 ms, r=0·85, P<0·001). In conclusion, the optimal AV delay can be predicted from the QT interval.

Key Words: PQ interval, QT interval, DDD pacemaker, atrioventricular block, cardiac output, atrioventricular delay


Correspondence: Toshiyuki Ishikawa, MD, Second Department of Internal Medicine, Yokohama City University Urafune Hospital, 3–46, Urafune-cho, Minami-ku, Yokohama 232–0024, Japan.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
T. Ishikawa, T. Sugano, S. Sumita, T. Nakagawa, K. Hanada, M. Kosuge, I. Kobayashi, K. Kimura, O. Tochikubo, T. Usui, et al.
Optimal atrioventricular delay setting determined by evoked QT interval in patients with implanted stimulus-T-driven DDDR pacemakers
Europace, January 1, 2001; 3(1): 46 - 51.
[Abstract] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.