Successful percutaneous extraction of an inadvertently placed left ventricular pacing lead
VU University Medical Center, Department of Cardiology 6 D 120 P.O. Box 7057, 1007 MB, Amsterdam, The Netherlands
A 74-year-old patient was referred for a rapidly increasing pacing threshold 9 months after DDD pacemaker implantation because of symptomatic total atrioventricular (AV) block. She had a history of hypertension, diabetes with micro-angiopathy and a recent transient ischaemic attack.
The paced electrocardiogram on admission had a right bundle branch block pattern and 3-dimensional transoesophageal echocardiography demonstrated passage of the lead through an atrial septal defect with a left ventricular position in addition to moderate atherosclerosis of the ascending aorta. No thrombus could be detected on the lead. Percutaneous extraction is usually not recommended because of the risk of mobilization of thrombus material. However, the risk of stroke during removal using cardiopulmonary bypass in this patient was considerably increased because of the presence of multiple independent risk factors. Therefore, percutaneous extraction using a locking device was selected and performed without complications: follow-up was uneventful.
Key Words: Lead extraction, endocardial left ventricular pacing
[1] Huang WM, Xin ZP, Tung CL. An unusual electrocardiographic pattern of left ventricular endocardial pacing. Pacing Clin Electrophysiol 1980; 3: 597599.[Medline]
[2] Shmuely H, Erdman S, Strasberg B, et al. Seven years of left ventricular pacing due to malposition of the pacing lead. Pacing Clin Electrophysiol 1992; 15: 369372.[Medline]
[3] Van Erckelens F, Sigmund M, Lambertz H. Asymptomatic left ventricular malposition of a transvenous pacemaker lead through a sinus venosus defect: Follow-up over 17 years. Pacing Clin Electrophysiol 1991; 14: 989993.[CrossRef][Medline]
[4] Stillman MT and Richards AM. Perforation of the interventricular septum by transvenous pacemaker electrode. Am J Cardiol 1969; 24: 269273.[CrossRef][Web of Science][Medline]
[5] Villanueva FS, Heinsimer JA, Burkman MH, et al. Echocardiographic detection of perforation of the interventricular septum by a permanent pacemaker lead. Am J Cardiol 1987; 59: 370371.[Medline]
[6] Meyer JA and Millar K. Perforation of the right ventricle by electrode catheters. Ann Surg 1968; 168: 10481060.[Web of Science][Medline]
[7] Trohman RG, Wilkoff BL, Byrne T, et al. Successful percutaneous extraction of a chronic left ventricular pacing lead. Pacing Clin Electrophysiol 1991; 14: 14481451.[CrossRef][Medline]
[8] Van Gelder BM, Bracke FA, Oto A, et al. Diagnosis and management of inadvertently placed pacing and ICD leads in the left ventricle: a mulicenter experience and review of the literature. Pacing Clin Electrophysiol 2000; 23: 877883.[CrossRef][Medline]
[9] Salazar JD, Wityk RJ, Grega MA, et al. Stroke after cardiac surgery: short- and long-term outcomes. Ann Thorac Surg 2001; 72: 11951201.
[10] Nussmeier NA. A review of risk factors for adverse neurologic outcome after cardiac surgery. J Extra Corpor Technol 2002; 34: 410.[Medline]
![]()
CiteULike
Connotea
Del.icio.us What's this?
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||