Skip Navigation

Europace 2002 4(3):311-315; doi:10.1053/eupc.2002.0235
© 2002 by European Society of Cardiology
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Christ, T.
Right arrow Articles by Ravens, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Christ, T.
Right arrow Articles by Ravens, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


REGULAR ARTICLES

Rate-adaptive pacing using intracardiac impedance shows no evidence for positive feedback during dobutamine stress test

Torsten Christ1, Matthias Schier3, Arne Brattström3, Gerhardt Muth2, Andreas Hartmann2, Dobromir Dobrev1 and Ursula Ravens1

1Department of Pharmacology and Toxicology, Medical Faculty, University of Technology Dresden, Germany; 2Department of Internal Medicine, St. George's Hospital Leipzig, Germany; 3Department of Biomedical Engineering, Friedrich-Alexander-University Erlangen-Nürnberg, Germany

BACKGROUND: The Inos2 DDDR pacemaker senses unipolar intracardiac impedance signals for adapting heart rate to meet the haemodynamic needs of physical activity. Theoretically, such pacing devices could be limited by positive feedback since increase in beating frequency per se enhances contractility. We have addressed this problem in patients with chronotropic incompetence who were subjected to a pharmacological stress test.

METHODS AND RESULTS: Twelve patients with chronically implanted Inos2 DDDR pacemakers were studied using the standard protocol of stress echocardiography. Most of the patients reached the programmable maximum closed-loop rate during the incremental dobutamine challenge. The time courses for increase in as well as for recovery of heart rate were not different from control patients receiving routine diagnostic stress echocardiography.

CONCLUSIONS: In patients implanted with the Inos2 DDDR pacemaker acute stimulation with intravenous dobutamine leads to a robust increase in paced heart rate without any evidence of positive feedback. Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.

Key Words: Closed-loop stimulation, rate adaptive pacing, contractility


Correspondence: Dr med. Torsten Christ, Institut für Pharmakologie und Toxikologie, Fetscherstr. 74, D-01309 Dresden, Germany. Tel: +493514586279; Fax: +493514586315; E-mail: Christ{at}rcs.urz.tu-dresden.de


[1] Sopher SM and Camm AJ. Atrial pacing to prevent atrial fibrillation? J Interv Card Electrophysiol 2000; 4:(Suppl 1) 149–153.

[2] Gregoratos G, Cheitlin MD, Conill A, Epstein AE, Fellows C, Ferguson TB Jr, Freedman RA, Hlatky MA, Naccarelli GV, Saksena S, Schlant RC, Silka MJ. ACC/AHA guidelines for implantation of cardiac pacemakers and antiarrhythmia devices: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation). J Am Coll Cardiol 1998; 31: 1175–1209.[Free Full Text]

[3] Camm AJ and Fei L. Chronotropic incompetence. Part I: Normal regulation of the heart rate. Clin Cardiol 1996; 19: 424–428.[Web of Science][Medline]

[4] Lau CP and Camm AJ. Overview of ideal sensor characteristics. In Ellenbogen KA, Kay GN, Wilkof BL (Eds.). Clinical Cardiac Pacing 1995; Philadelphia Saunders pp. 143.

[5] Malinowski K. Interindividual comparison of different sensor principles for rate adaptive pacing. Pacing Clin Electrophysiol 1998; 21: 2209–2213.[CrossRef][Medline]

[6] Oral H, Armstrong WF, Bach DS. Preserved diagnostic utility of dobutamine stress echocardiography in pacemaker-dependent patients with absolute chronotropic incompetence. Am Heart J 1999; 138: 348–364.

[7] Ovsyshcher L, Guetta V, Bondy C, Porath A. First derivative of right ventricular pressure, dP/dt, as a sensor for rate adaptive VVI pacemaker: initial experience. Pacing Clin Electrophysiol 1992; 15: 211–218.[CrossRef][Medline]

[8] Yee R and Bennett TD. Rate-adaptive pacing controlled by dynamic right ventricular pressure (dP/dtmax). In Ellenbogen KA, Kay GN, Wilkof BL (Eds.). Clinical Cardiac Pacing 1995; Philadelphia Saunders pp. 216.

[9] Schaldach M. Electrotherapy of the Heart. 1992; Berlin Springer-Verlag pp. 114–115.

[10] Osswald S, Cron T, Gradel C, Hilti P, Lippert M, Strobel J, Schaldach M, Buser P, Pfisterer M. Closed-loop stimulation using intracardiac impedance as a sensor principle: correlation of right ventricular dP/dtmax and intracardiac impedance during dobutamine stress test. Pacing Clin Electrophysiol 2000; 23: 1502–1508.[CrossRef][Medline]

[11] Koch-Weser J and Blinks JR. The influence of the interval between beats on myocardial contractility. Pharmacol Rev 1963; 15: 601–652.[Abstract/Free Full Text]

[12] Geleijnse ML, Fioretti PM, Roelandt JR. Methodology, feasibility, safety and diagnostic accuracy of dobutamine stress echocardiography. J Am Coll Cardiol 1997; 30: 595–606.[Abstract]

[13] Heynen H, Sharma A, Sutton R, Camm J, Ovsyhcher I, Näslind U, Gillis AM, Clarke M, Ruiter J, Brachmann J, Schallhorn R, Bennett T. Clinical Experience with VVVIR pacing based on right ventricular dP/dt. Eur J Card Pacing Electrophysiol 1991; 1: 138–146.

[14] Schouten VJA. Interval dependence of force and twitch duration in rat heart explained by Ca2+ pump inactivation in sarcoplasmatic reticulum. J Physiol 1990; 43: 427–444.

[15] Layland J and Kentish JC. Effects of {alpha}1- or ß-adrenoceptor stimulation on work-loop and isometric contractions of isolated rat cardiac trabeculae. J Physiol 2000; 524: 205–219.[Abstract/Free Full Text]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?



This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Christ, T.
Right arrow Articles by Ravens, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Christ, T.
Right arrow Articles by Ravens, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?