Skip Navigation

Europace 2002 4(2):149-153; doi:10.1053/eupc.2002.0228
© 2002 by European Society of Cardiology
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Maury, P.
Right arrow Articles by Kappenberger, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maury, P.
Right arrow Articles by Kappenberger, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


CASE REPORTS

Incessant atrioventricular dissociation due to far-field QRS oversensing and recurrent mode switch in a dual chamber pacemaker

P. Maury, J. Schlaepfer, M. Arbane, G. Girod and L. Kappenberger

Division of Cardiology, University Hospital Lausanne, Switzerland

We report the case of a repetitive and incessant activation of mode switch in a dual chamber pacemaker because of the inappropriate sensing by the atrial lead of far-fields signals from the ventricular evoked response. The incidence, consequences and prevention of the oversensing of far-field QRS complexes are discussed. Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.

Key Words: Far-field QRS signal, mode switching, atrial oversensing, cross-talk


Correspondence: J. Schlaepfer, MD, Division de Cardiologie, Centre Hospitalier Vaudois Rue du Bugnon 19, 1011 Lausanne, Switzerland. E-mail: jurg.schlaepfer{at}chuv.hospvd.ch


[1] Lemke B. Problems of ‘automatic mode switching’. Herzschr Electrophys 1999; 10: I/1–I/3.

[2] Israel CW and Lawo T. Use of an advanced mode switching algorithm in Inos2 CLS and Logos dual chamber pacemakers. Herzschr Electrophys 1999; 10: I/72–I/80.[CrossRef]

[3] Shandling AH, Castellanet MJ, Messenger JC, Brownlee RR. Utility of the atrial endocardial electrogram concurrent with dual-chamber pacing in the determination of a pacemaker-mediated arrhythmia. Pacing Clin Electrophysiol 1988; 11: 1419–1425.[Medline]

[4] Johnson CD. Atrial synchronous ventricular inhibited (VDD) pacemaker mediated arrhythmia due to atrial undersensing and atrial lead oversensing of far-field ventricular afterpotentials or paced beats: crosstalk. Pacing Clin Electrophysiol 1986; 9: 710–719.[Medline]

[5] Sermasi S and Marconi M. VDD single-pass lead pacing: sustained pacemaker-mediated tachycardias unrelated to retrograde conduction. Pacing Clin Electrophysiol 1992; 15: 1903–1907.[Medline]

[6] Brandt J and Worzewski W. Far-field QRS complex sensing: prevalence and timing with bipolar atrial leads. Pacing Clin Electrophysiol 2000; 23: 315–320.[Medline]

[7] Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. I. Mechanism, consequences, differential diagnosis and countermeasures in AAI and VDD/DDD pacing. Pacing Clin Electrophysiol 1988; 11: 1432–1438.[Medline]

[8] Frohlig G, Helwani Z, Kusch O, Berge M, Schieffer H. Bipolar ventricular far-field signals in the atrium. Pacing Clin Electrophysiol 1999; 22: 1604–1613.[Medline]

[9] Brouwer J, Nagelkerke D, den Heijer P, et al. Analysis of atrial sensed far-field ventricular signals: a reassessment. Pacing Clin Electrophysiol 1997; 20: 916–922.[CrossRef][Medline]

[10] Brandt J, Fåhraeus T, Schüller H. Far-field QRS complex sensing via the atrial pacemaker lead. II. Prevalence, clinical significance and possibility of intraoperative prediction in DDD pacing. Pacing Clin Electrophysiol 1988; 11: 1540–1544.[Medline]

[11] Fitts SM, Hill MRS, Mehra R, Gillis AM. Pacing Clin Electrophysiol 2000; 23: 1080–1086.[CrossRef][Medline]

[12] Nowak B, Middeldorf T, Voigtländer T, et al. How reliable is atrial sensing in single lead VDD pacing. Pacing Clin Electrophysiol 1998; 21: 2226–2231.[Medline]

[13] Wolpert C, Jung W, Scholl C, Spehl S, Cyran J, Lüderitz B. Electrical proarrhythmia: induction of inappropriate atrial therapies due to far-field R wave oversensing in a new dual chamber defibrillator. J Cardiovasc Electrophysiol 1998; 9: 859–863.[Web of Science][Medline]

[14] Timmis GC, Westveer DC, Gadowsli G, et al. The effect of electrode position on atrial sensing for physiologically responsive cardiac pacemakers. Am Heart J 1984; 108: 909–916.[CrossRef][Web of Science][Medline]

[15] Theres H, Sun W, Combs W, et al. P wave and far-field R wave detection in pacemaker patient atrial electrogram. Pacing Clin Electrophysiol 2000; 23: 434–440.[Medline]

[16] De Boer H, Kofflard M, Scholtens T, et al. Differential bipolar sensing of a dual chamber pacemaker. Pacing Clin Electrophysiol 1988; 11: 158–165.[Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
J. W.H. Fung, J. Sperzel, C. M. Yu, J. Y.S. Chan, R. N. Gelder, M. X. Yang, R. Rooke, P. Boileau, and G. Frohlig
Multicenter clinical experience with an atrial lead designed to minimize far-field R-wave sensing
Europace, May 1, 2009; 11(5): 618 - 624.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. Lewicka-Nowak, A. Kutarski, A. Dabrowska-Kugacka, P. Rucinski, P. Zagozdzon, and G. Raczak
Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing
Europace, February 1, 2008; 10(2): 138 - 146.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. Nash, G. Fröhlig, M. Taborsky, E. Stammwitz, F. Maru, L.H.M. Bouwens, and C. Çeliker
Rejection of atrial sensing artifacts by a pacing lead with short tip-to-ring spacing
Europace, January 1, 2005; 7(1): 67 - 72.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Maury, P.
Right arrow Articles by Kappenberger, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maury, P.
Right arrow Articles by Kappenberger, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?