EDITORIAL
High impedance leads and safety margin. Electrical considerations based on a simplified expression of the paradigm
CHU de Bordeaux, Hôpital Cardiologique du Haut-Lévêque 33604, Pessac Cedex, France; 1Florida Cardiovascular Institute and Tampa General Hospital Tampa, U.S.A.
Abstract
For physicians who are not familiar with the electrical basis of cardiac stimulation, high impedance leads previously (10 years ago) considered as bad electrodes (high voltage) are now considered as the epitome of lead technology (low energy drain): clearly impedance is not a good parameter for characterizing the qualities of a pacing lead. Using a simplified approach to the electrostimulation paradigm, it is easy to establish that modern high impedance leads are in fact high current density leads and high efficiency leads (better description). It is also possible to establish that routine programming of the safety margin at 100% above threshold parameters is associated with a decrease in the penetration of the electric field according to the reduction of the cathode surface area. For safety and energy saving, a small tip electrode could be combined with a low polarization surface treatment and a reduction in fibrosis development between electrode and myocardium.Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.
Key Words: Pacing leads, high impedance, safety margin, strength/duration curve, electrostimulation law, electrostimulation paradigm
Correspondence: CHU de Bordeaux, Hôpital Cardiologique du Haut-Lévêque, Avenue de Magellan, 33604 Pessac Cedex, France. E-mail: jacques.clementy{at}pu.u-bordeaux2.fr
References
[1] American College of Cardiology. American Heart Association Guidelines for implantation of cardiac pacemakers and antiarrhythmia devices. J Am Coll Cardiol 1998; 31: 11751209.
[2] Bernstein AD, Irwin ME, Parsonnet V, et al. Report of the NASPE Policy Conference on antibradycardia pacemaker follow-up: effectiveness, needs and resources. Pacing Clin Electrophysiol 1994; 17: 17141729.[CrossRef][Medline]
[3] Daubert JC. Should the race for pulse generator miniaturization be stopped? Pacing Clin Electrophysiol 1996; 19: 46.[Medline]
[4] Ohm OJ and Danilovic D. Improvements in pacemaker energy consumption and functional capability: four decades of progress. Pacing Clin Electrophysiol 1997; 20: 29.[CrossRef][Medline]
[5] Presented during Core Session, p. 4: Basic pacing and defibrillation I - Fundamental principles of cardiac stimulation, 15th Annual Scientific Session of NASPE, Nashville, Tennessee, June 13, 1994 Stokes KB and McVenes R. How do pacemakers stimulate?
[6] Lapicque L. Definition experimental de l'excitabilité. Soc Biol 1909; 77: 280283.
[7] Furman S, Garvey J, Hurzeler Ph. Pulse duration variation and electrode size as a factor in pacemaker longevity. J Thorac Cardiovasc Surg 1975; 69: 382389.[Abstract]
[8] Furman S, Parker B, Escher DJW. Decreasing electrode size and increasing efficiency of cardiac stimulation. J Surg Res 1971; 11: 105110.[Medline]
[9] Mond H, Holley L, Hirshorn M. The high impedance dish electrode clinical experience with a new tined lead. Pacing Clin Electrophysiol 1982; 5: 529534.[Medline]
[10] Hein F, Blaser R, Thull R, et al. Electrochemical aspects of pacing electrodes (discussion). In Watanabe Y (Ed.). Cardiac Pacing Proceedings of the Vth International Symposium, Tokyo 1977; Amsterdam Experta Medica pp. 510515.
[11] Parsonnet V, Gilbert L, Lewin G, et al. A nonpolarizing electrode for endocardial stimulation of the heart. J Thorac Cardiovasc Surg 1974; 56: 710716.
[12] Taylor D, Oakley D, Rowbotham D, et al. Comparison of a porous tipped with a conventional endocardial pacing lead. Pacing Clin Electrophysiol 1981; 5: A-76 (Abstract).
[13] Omerod D, Walgren S, Berglund J, et al. Design and evaluation of a low threshold, porous tip lead with a mannitol coated screw-in tip (sweet tip). Pacing Clin Electrophysiol 1988; 11: 496.
[14] Karpawich PP, Stokes KB, Helland JR, et al. A new low threshold platinized epimyocardial pacing electrode: comparative evaluation in immature canines. Pacing Clin Electrophysiol 1988; 11: 11391148.[Medline]
[15] Djordjevic M, Srojanov P, Velimirovic D. Target lead low threshold electrode. Pacing Clin Electrophysiol 1986; 9: 12061210.[Medline]
[16] Irnich W. The chronaxie time and its practical importance. Pacing Clin Electrophysiol 1980; 3: 292.[Medline]
[17] Bernstein AD and Parsonnet V. Implications for constant-energy pacing. Pacing Clin Electrophysiol 1983; 6: 12291235.[Medline]
[18] Irnich W. Paradigm shift in lead design. Pacing Clin Electrophysiol 1999; 22: 13211332.[CrossRef][Medline]
[19] Radovsky AS and Van Vleet JF. Effects of dexamethasone elution on tissue reaction around stimulating electrodes of endocardial pacing leads in dogs. Am Heart J 1989; 117: 12881293.[CrossRef][Web of Science][Medline]
[20] Pioger G and Ripart A. Clinical results of low energy unipolar or bipolar activated carbon tip leads. Pacing Clin Electrophysiol 1986; 9: 12431248.[Medline]
[21] Stokes KB, Bornzin GA, Wiebusch WA. A steroid-eluting, low-threshold, low-polarising electrode. In Steinbach K, Glogar D, Laszkovics S (Eds.), et al. Cardiac Pacing Proceedings of the VIIth World Symposium on Cardiac Pacing, Vienna 1983; Darmstadt Steinkopff Verlag pp. 369376.
[22] Beanlands DS, Akyurekli Y, Keon WJ. Predinisolone in the management of exit block. In Meere C (Ed.). Proceedings of the Sixth World Symposium On Cardiac Pacing 1979; Montreal Pacesymp pp. 1318.
[23] Kruse IM. Long-term performance of endocardial leads with steroid-eluting electrodes. Pacing Clin Electrophysiol 1986; 9: 12171219.[Medline]
[24] Aonuma K, Iesaka Y, Nogami A, et al. Long-term improvement of atrial pacing threshold and sensitivity with steroid tip leads: a comparative study between steroid and target tip lead. Pacing Clin Electrophysiol 1988; 11: 510.
[25] Mond HG and Helland JR. Engineering and clinical aspects of pacing leads. In Ellenbogen KA, Kay GN, Wilkoff BL (Eds.). Clinical Cardiac Pacing 1995; Philadelphia WB Saunders pp. 6990.
![]()
CiteULike
Connotea
Del.icio.us What's this?
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||