Skip Navigation

Europace 2001 3(1):80-84; doi:10.1053/eupc.2000.0145
© 2001 by European Society of Cardiology
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Duru, F.
Right arrow Articles by Candinas, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Duru, F.
Right arrow Articles by Candinas, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


CASE REPORT

Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion

F. Duru, U. Bauersfeld and R. Candinas

Cardiac Arrhythmia Unit, University Hospital of Zurich Zurich, Switzerland

Appropriate sensing is an essential function of an implantable cardioverter defibrillator (ICD). T-wave oversensing by an ICD can be a serious problem in some patients, causing overestimation of the heart rate, inappropriate tachyarrhythmia detection and therapy delivery. Decreasing the sensitivity or programming longer refractory periods can sometimes overcome T-wave oversensing, but these measures may interfere with the ability of the ICD to correctly detect tachyarrhythmias. This report proposes a novel application of the electrogram (EGM) width criterion using a recently introduced detection enhancement algorithm intended to improve the specificity of ventricular tachycardia detection, to avoid T-wave oversensing. Based on the course of a case with persistent T-wave oversensing and review of previously published reports, oversensing problems in ICDs and management strategies are discussed.

Key Words: T-wave oversensing, implantable cardioverter defibrillator, ventricular tachycardia, detection enhancement, electrogram width criterion


Correspondence: Firat Duru, Cardiac Arrhythmia Unit, University Hospital of Zurich, Raemistr. 100, CH-8091, Zurich, Switzerland. E-mail: firat.duru{at}dim.usz.ch


[1] Barold SS, Falkoff MD, Ong LS, Heinle RA. Oversensing by single-chamber pacemakers: mechanisms, diagnosis, and treatment. Cardiol Clin 1985; 3: 565–585.[Medline]

[2] Singer I, de Borde R, Veltri EP, et al. The automatic implantable cardioverter defibrillator: T wave sensing in the newest generation. Pacing Clin Electrophysiol 1988; 11: 1584–1591.[CrossRef][Medline]

[3] Grimm W, Flores BF, Marchlinski FE. Electrocardiographically documented unnecessary, spontaneous shocks in 241 patients with implantable cardioverter defibrillators. Pacing Clin Electrophysiol 1992; 15: 1667–1673.[CrossRef][Medline]

[4] Grimm W, Flores BF, Marchlinski FE. Complications of implantable cardioverter defibrillator therapy: follow-up of 241 patients. Pacing Clin Electrophysiol 1993; 16: 218–222.[CrossRef][Medline]

[5] Hook BG, Callans DJ, Kleiman RB, Flores BT, Marchlinski FE. Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis. Circulation 1993; 87: 1897–1906.[Abstract/Free Full Text]

[6] Kelly PA, Mann DE, Damle RS, Reiter MJ. Oversensing during ventricular pacing in patients with a third-generation implantable cardioverter-defibrillator. J Am Coll Cardiol 1994; 23: 1531–1534.[Abstract]

[7] Reiter MJ and Mann DE. Sensing and tachyarrhythmia detection problems in implantable cardioverter defibrillators. J Cardiovasc Electrophysiol 1996; 7: 542–558.[Web of Science][Medline]

[8] Deshmukh P and Anderson K. Myopotential sensing by a dual chamber implantable cardioverter defibrillator: two case reports. J Cardiovasc Electrophysiol 1998; 9: 767–772.[Web of Science][Medline]

[9] Calkins H, Brinker J, Veltri EP, Guarnieri T, Levine JH. Clinical interactions between pacemakers and automatic implantable cardioverter-defibrillators. J Am Coll Cardiol 1990; 16: 666–673.[Abstract]

[10] Sticherling C, Klingenheben T, Skupin M, Li YG, Hohnloser SH. Kombinierte Therapie mit transvenosen Kardioverter/Defibrillator- und antibradykarden Schrittmachersystemen. Z Kardiol 1997; 86: 105–112.[Medline]

[11] Geiger MJ, O'Neill P, Sharma A, et al. Interactions between transvenous nonthoracotomy cardioverter defibrillator systems and permanent transvenous endocardial pacemakers. Pacing Clin Electrophysiol 1997; 20: 624–630.[CrossRef][Medline]

[12] Curwin JH, Roelke M, Ruskin JN. Inhibition of bradycardia pacing caused by far-field atrial sensing in a third-generation cardioverter defibrillator with an automatic gain feature. Pacing Clin Electrophysiol 1996; 19: 124–126.[CrossRef][Medline]

[13] Yokoyama M, Wada J, Barold SS. Transient early T wave sensing by implanted programmable demand pulse generator. Pacing Clin Electrophysiol 1981; 4: 68–74.[CrossRef][Medline]

[14] Perry GY and Kosar EM. Problems in managing patients with long QT syndrome and implantable cardioverter defibrillators: a report of two cases. Pacing Clin Electrophysiol 1996; 19: 863–867.[CrossRef][Medline]

[15] Frazier DW and Stanton MS. Pseudo-oversensing of the T wave by an implantable cardioverter defibrillator: a nonclinical problem. Pacing Clin Electrophysiol 1994; 17: 1311–1315.[Medline]

[16] Mann DE, Damle RS, Kelly P, Landers M, Otto L, Reiter MJ. Comparison of oversensing during bradycardia pacing in two types of implantable cardioverter-defibrillator systems. Am Heart J 1998; 136: 658–663.[Medline]

[17] Minten J, Cuypers A, van Binsbergen E. Medtronic Model 7219 Jewel PCD European Clinical Report.

[18] Use of the EGM Width Criterion to discriminate VT from SVT.Tachyarrhythmia Technical Concept Paper (Medtronic). Volume 2, Number7.

[19] Klingenheben T, Sticherling C, Skupin M, Hohnloser SH. Intracardiac QRS electrogram width — an arrhythmia detection feature for implantable cardioverter defibrillators: exercise induced variation as a base for device programming. Pacing Clin Electrophysiol 1998; 21: 1609–1617.[Medline]

[20] Duru F, Schönbeck M, Lüscher TF, Candinas R. The potential for inappropriate ventricular tachycardia confirmation using the intracardiac electrogram width criterion. Pacing Clin Electrophysiol 1999; 22: 1039–1046.[CrossRef][Medline]

[21] Duru F, Schönbeck M, Candinas R. The need for exercise testing for optimal programming of the EGM width criterion in patients with an implantable defibrillator (abstract). J Am Coll Cardiol 1999; 33: 133.

[22] Duru F, Junga G, Schönbeck M, Candinas R. Effect of slew threshold on electrogram width during ventricular tachycardia: Recommendations for optimal function of the EGM width criterion in an implantable cardioverter-defibrillator (abstract). Kardiovaskuläre Medizin 1999; 2: 51.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
K. Srivathsan, L. R. Scott, and G. T. Altemose
T-wave oversensing and inappropriate shocks: a case report
Europace, May 1, 2008; 10(5): 552 - 555.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
T. Rauwolf, M. Guenther, N. Hass, A. Schnabel, M. Bock, M.U. Braun, and R.H. Strasser
Ventricular oversensing in 518 patients with implanted cardiac defibrillators: incidence, complications, and solutions
Europace, November 1, 2007; 9(11): 1041 - 1047.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Duru, F.
Right arrow Articles by Candinas, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Duru, F.
Right arrow Articles by Candinas, R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?