Skip Navigation



Europace Advance Access published online on August 11, 2008

Europace, doi:10.1093/europace/eun208
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/11/1313    most recent
eun208v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Buck, S.
Right arrow Articles by Van Gelder, I. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buck, S.
Right arrow Articles by Van Gelder, I. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org

Impact of interventricular lead distance and the decrease in septal-to-lateral delay on response to cardiac resynchronization therapy

Sandra Buck1, Alexander H. Maass1, Wybe Nieuwland1, Rutger L. Anthonio1, Dirk J. Van Veldhuisen1 and Isabelle C. Van Gelder1,2,*

1 Department of Cardiology, Thoraxcenter, University Medical Center Groningen, University of Groningen, Hanzeplein 1, PO Box 30.001, 9700 RB Groningen, The Netherlands; 2 The Interuniversity Cardiology Institute Netherlands, Utrecht, The Netherlands

Manuscript submitted 4 June 2008. Accepted after revision 19 July 2008.

* Corresponding author. Tel: +31 50 361 2355; fax: +31 50 361 4391. E-mail address: i.c.van.gelder{at}thorax.umcg.nl


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
Aims: To investigate the influence of interlead distance and lead positioning on success of cardiac resynchronization therapy (CRT) in patients with advanced chronic heart failure and electrical dyssynchrony. Despite application of established selection criteria, 20–40% of the patients do not respond to CRT.

Methods and results: We examined consecutive patients in whom CRT was implanted. Response to CRT was defined as a decrease in the left ventricular end-systolic volume ≥10% after 6 months. A comparison was made between patients who were responders to CRT and those who were non-responders. A univariate and stepwise multivariate logistic regression was performed with regard to predictors for response. Between January 2004 and January 2008, 174 patients who were treated with CRT were classified as responders [n = 95 (55%)] or non-responders [n = 79 (45%)]. Responders had a significantly larger horizontal interlead distance on the lateral thoracic X-ray [odds ratio (OR) 2.8 (1.2–6.6), P = 0.01], a septal-to-lateral delay >60 ms [OR 4.9 (2.0–11.4), P < 0.0001], non-ischaemic cardiomyopathy [OR 3.0 (1.3–6.9), P = 0.009], a left ventricular end-diastolic diameter <67 mm [OR 4.2 (1.8–9.9), P = 0.001], angiotensin-converting enzyme inhibitor use [OR 8.1 (1.7–38.2), P = 0.008], and no tricuspid valve insufficiency [OR 6.9 (1.3–35.5), P = 0.02]. Post-implantation responders had a significantly greater decrease in the intraventricular delay (septal-to-lateral delay 62 ± 62 vs. 26 ± 65 ms, P = 0.001), but not in the interventricular mechanical delay.

Conclusion: Larger interlead distance on the lateral thoracic X-ray, associated with positioning of the left ventricular lead in the posterior position, is associated with response after 6 months of follow-up. Furthermore, diminishing the septal-to-lateral delay is predictive for response.

Key Words: Congestive heart failure, Artificial pacing, Cardiac resynchronization therapy


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
Heart failure is the fastest growing cardiovascular diagnosis; the lifetime risk is estimated at nearly 20%. According to epidemiological studies, an estimated 22.5 million people suffer from heart failure worldwide.1Go Intraventricular conduction disturbances are common and are associated with an increased mortality.2Go,3Go

Several randomized clinical trials have demonstrated the beneficial effects of cardiac resynchronization therapy (CRT) in patients with pharmacological refractory heart failure.3Go–10Go These studies have shown an improvement in clinical (symptoms, exercise capacity, quality of life, and mortality) and echocardiographic endpoints (systolic function, left ventricular (LV) size, and mitral valve regurgitation). However, depending on the criteria used for the definition of response, 20–40% of the patients do not respond to CRT.

At present, the eligibility criteria for CRT are New York Health Association (NYHA) functional class III or IV despite optimal pharmacological treatment, LV ejection fraction ≤35%, left ventricular end-diastolic diameter (LVEDD) ≥55 mm, and wide QRS complex ≥130 ms.11Go According to the recent literature, evident dyssynchrony by echocardiography was taken into account in case of a QRS duration ≤130 ms.12Go A decrease in the left ventricular end-systolic volume (LVESV) of ≥10% has been shown to be predictive for lower long-term mortality and heart failure events.12Go,13Go

Positioning of the LV lead is often difficult due to the characteristics of the coronary venous anatomy, unacceptable electrical parameters in the target area, phrenic nerve stimulation, and/or other technical difficulties. The aim of the present study was to investigate the independent influence of interlead distance and thus lead position on response to CRT.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
Patient population
Between January 2004 and January 2008, 194 consecutive patients with congestive heart failure received CRT. Patients who died prior to 6 months of follow-up and thus did not have a follow-up cardiac ultrasound to determine the changes in LVESV were not included in the analysis (n = 20). Response was defined as a decrease of ≥10% in LVESV after 6 months of follow-up. A total of 95 (55%) patients were classified as responders and the remaining 79 (45%) patients were non-responders.

Baseline assessment included patient history, physical examination, 12 lead-electrocardiogram (ECG), transthoracic echocardiography, exercise testing, radionuclide scanning, and coronary angiography. Clinical history and characteristics were retrieved using patients' medical records. QRS duration was determined using ECG stored in medical records. A transthoracic echocardiography was made to determine whether there were signs of tricuspidalis valve or mitral valve regurgitation; the severity of regurgitation was graded semi-quantitatively from colour flow Doppler in the parasternal long axis and apical four-chamber images. Left ventricular end-diastolic and end-systolic diameters were determined by M-mode echocardiography in the parasternal long-axis view, according to the guidelines of the American Society of Echocardiography.14Go Left ventricular end-diastolic and end-systolic volumes were measured using the modified biplane Simpson method, using the apical four-chamber and two-chamber views.15Go

Mechanical dyssynchrony was determined by tissue velocity imaging (TVI), using Echopac 6.1.3, General Electric Vivid 7®. We evaluated the aortic pre-ejection time, interventricular mechanical delay (IVMD), and septal-to-lateral delay by TVI. An IVMD >40 ms was considered indicative of interventricular mechanical dyssynchrony.12Go Intraventricular LV dyssynchrony was measured by calculating the septal-to-lateral delay. A mechanical delay >60 ms was considered indicative of intraventricular dyssynchrony.12Go

The positioning of right ventricular (RV) and LV lead was determined by chest X-rays in postero-anterior and lateral views, at maximal inspiration, typically on the day after device placement. The LV lead tip position was defined as posterior (within the posterior one-third of the heart shadow on the lateral radiograph), all other positions were defined as other. The interlead distance is measured on a digital radiology workstation, where the thoracic width, the cardiac width, the direct RV–LV electrode tip separation, and the horizontal and vertical components of LV–RV electrode tip separation were measured. (Figure 1) All measurements were divided by the cardiothoracic ratio to account for relative differences in cardiac and thoracic sizes between patients, thus creating the corrected interlead distance.


Figure 1
View larger version (82K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 Measurement of the right ventricular–left ventricular interlead distance in the antero-posterior (A) and lateral (B) positions. Interlead distance measured as direct (D), horizontal (H), and vertical (V) on each radiograph.

 
All available coronary sinus angiograms, in total 156 (90%), were examined to determine into which coronary vein the LV lead was positioned. Correlation with regard to lead position on thoracic X-ray was evaluated.

Follow-up
After implantation, all patients underwent echocardiography to determine the persistence of IVMD and/or septal-to-lateral delay. Thereafter, all patients were routinely seen every 6 months at the outpatient department. At all visits, patient history, medication use, physical examination, ECG, pacemaker interrogation, transthoracic echocardiography, a radionuclide scan, and exercise test were performed. At each CRT interrogation, data were stored both on computer disc and in a computerized ICD medical record database of the University Medical Center Groningen. A consistent protocol to standardize CRT and ICD programming was used. VV delay was set to 0 ms, and AV delay optimization was performed 2 weeks post-implantation. The duration of follow-up was computed from the time of CRT implantation until death or heart transplantation when applicable, or to the date when the last follow-up data were obtained. The determination of whether the patient was a responder or a non-responder was based on the LVESV measured by echocardiographic ultrasound at 6 months of follow-up.

Statistical analysis
Baseline descriptive statistics are presented as mean±standard deviation (SD) or median (range) for continuous variables and numbers with percentages for categorical variables. Differences between variables in responders vs. non-responders were evaluated by Student's t-test or Mann–Whitney U test, depending on the normality of the data, for continuous data and Fisher's exact test or {chi}2 test for categorical data.

We calculated adjusted odds ratios (ORs) of clinical characteristics, baseline drug therapy, and device characteristics with logistic regression, to identify predictors of CRT response. Linearity of the continuous variables with respect to the response variable was assessed by determining the quartiles of their distribution. Thereafter, ORs for each quartile were calculated. In the case of a linear trend in the estimated ORs, the variable was introduced in the model as continuous. If no linearity was shown, the variable was further categorized by taking together the quartiles with ORs similar in magnitude, primarily the median value or otherwise based on clinical relevance. Multivariate analysis was performed using all variables with P < 0.10 in the univariate analysis. A stepwise approach was used. The final model included all variables with P < 0.05; variables with P ≥ 0.05 in the multivariate model were excluded; interaction was investigated. In all analysis, P < 0.05 was considered statistically significant.


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
Patients' characteristics
We included 174 patients, of which 95 (55%) were responders to CRT after 6 months of follow-up. The baseline characteristics are shown in Table 1. Responders significantly more frequently suffered from non-ischaemic cardiomyopathy (NICMP), more frequently had an IVMD >40 ms, a septal-to-lateral delay >60 ms, a smaller left atrium, smaller LV diameters and volumes, and a higher estimated Glomerular filtration rate.


View this table:
[in this window]
[in a new window]

 
Table 1 Baseline characteristics of responders vs. non-responders

 
The desired LV lead position during implantation was the postero-lateral vein. This was thought to be achieved in 138 patients (79%), whereas in 17 patients (10%), the LV lead was positioned in the antero-lateral vein and in 1 patient (1%) in the mid cardiac vein.

Analysis of the thoracic X-rays proved that the RV lead most frequently was placed in the apex and the LV lead in the posterior position. Responders significantly had a larger corrected horizontal interlead LV–RV distance, on the lateral X-ray. (Table 2) This coincided with the LV lead more frequently being positioned in the posterior position (Figure 2).


Figure 2
View larger version (10K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 2 Interlead distance and lead position. *P < 0.0001.

 


View this table:
[in this window]
[in a new window]

 
Table 2 Lead positioning

 
There was no correlation between coronary sinus vein positioning and response to CRT [79 (57%) responders vs. 59 (43%) non-responders, in whom the LV lead was positioned in the postero-lateral vein, and 7 (39%) vs. 11 (61%) positioned in other veins, respectively, P = 0.39]. Analysis with regard to vein positioning and thoracic X-ray localization of the LV lead proved that a total of 32 patients (23%), in whom LV lead was thought to be positioned in the postero-lateral vein, eventually had the LV lead positioned in a different position after evaluation by thoracic X-ray, being anterior. A total of two patients (11%) in whom the LV lead was thought to be positioned in the antero-lateral vein, analysis of the thoracic X-ray proved that the LV lead was positioned in a posterior position.

Dyssynchrony after implantation
The septal-to-lateral delay was significantly more reduced in responders after implantation (62 ± 62 vs. 26 ± 65, P = 0.001) (Figure 3). Responders significantly less frequently had a septal-to-lateral delay >60 ms after implantation of the CRT device [11 (12%) vs. 28 (35%), P = < 0.0001].


Figure 3
View larger version (10K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 3 Changes in septal-to-lateral delay between responders and non-responders (A) and with regard to lead positioning (B). *P = 0.001 and **P = 0.02.

 
There was no significant difference in the reduction of IVMD between both groups (14 ± 38 vs. 13 ± 39, P = 0.39).

Evaluation of the lead positioning showed that the septal-to-lateral delay significantly more diminishes in patients in whom the LV lead is positioned posteriorly. (Figure 3).

Response to therapy
Median follow-up was 21 ± 12 months. After 6 months of follow-up, 95 (55%) patients were defined as responders. The LVESV had decreased significantly in responders, whereas non-responders showed a significant increase in the LVESV (Figure 4A). The LVEF significantly increased in responders, whereas in the non-responders, it decreased slightly (Figure 4B). After 6 months of follow-up, 128 patients were responders with a decrease of one or more points in the NYHA class. Of the echocardiographic responders, 73 (78%) patients were NYHA responders, whereas the remaining 21 (22%) echocardiographic responders did not improve in NYHA class. Of the echocardiographic non-responders, 55 (70%) patients improved one or more points in the NYHA class.


Figure 4
View larger version (10K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 4 Changes in haemodynamic parameters during follow-up. Changes in left ventricular end-systolic volume (A) and in left ventricular ejection fraction (B) in responders and non-responders. *P < 0.01.

 
The multivariate analysis revealed that a horizontal interlead distance on the lateral X-ray >127 mm [OR 2.8 (1.2–6.6), P = 0.01], a septal-to-lateral delay >60 ms [OR 4.9 (2.0–11.4), P < 0.0001], NICMP [OR 3.0 (1.3–6.9), P = 0.009], LVEDD <67 mm [OR 4.2 (1.8–9.9), P = 0.001], angiotensin-converting enzyme (ACE) inhibitor use [OR 8.1 (1.7–38.2), P = 0.008], and no tricuspid valve regurgitation [OR 6.9 (1.3–35.5), P = 0.02] were related to response (Table 3).


View this table:
[in this window]
[in a new window]

 
Table 3 Univariate and stepwise multivariate logistic regression analyses with regard to predictor responder

 

    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
This study demonstrates that the interlead distance, in particular, the horizontal interlead distance on the lateral thoracic X-ray, is associated with response to CRT after 6 months of follow-up. The horizontal interlead distance correlated best with a posterior positioning of the LV lead. None of the other interlead distances were of influence on response. This suggests that the currently desired lateral placement of the LV lead is of less importance for response to CRT. Furthermore, response to CRT was associated with the diminishing of the septal-to-lateral delay during follow-up. This reduction of the septal-to-lateral delay was significantly more when the LV lead was positioned in the posterior position. This strengthens the body of evidence that relieving mechanical dyssynchrony is the basis for the efficacy of biventricular stimulation.

Response to cardiac resynchronization therapy
In the present study, 55% of the patients were responders to CRT, defined as a decrease in the LVESV of ≥10%. This is in accordance with the results found by Yu et al.13Go The response rate was significantly higher when improvement in one or more NYHA class was evaluated. In accordance with our data, other studies found a poor correlation between clinical response and echocardiographic response to CRT.16Go

Influence of lead positioning
In our analysis, a larger horizontal interlead distance on the lateral thoracic X-ray correlated with response. This coincided with a posterior positioning of the LV lead and offers an advantage over other lead positions. Our analysis proved that the desired coronary vein (postero-lateral) is sometimes difficult to predict with the current fluoroscopic views. In our cohort, in a large percentage (22%), the LV lead was placed in a different location than predicted from the coronary venogram. This is most likely due to variable coronary venous anatomy, which does not always follow strict rules such as coronary arteries. By changing the current fluoroscopic views used for the implantation of the LV lead left anterior oblique (LAO) 30° to 40° to a fluoroscopic view LAO 90°, frequently used in coronary angiography, the best posterior vein can be selected. Hereby, it should be taken into account that the choice of LV electrode site for best resynchronization is often difficult because of the characteristics of the coronary venous anatomy, unacceptable electrical parameters in the target area, phrenic nerve stimulation, or other technical difficulties. Earlier studies have shown the lateral or postero-lateral part of the left ventricle as the site that provides greatest acute haemodynamic benefit, particularly for dP/dt.17Go–20Go Butter et al.19Go found that the acute haemodynamic effects were significantly better when the LV lead was positioned in the free wall compared with an anterior positioning of the LV lead. Along the same lines, Rossillo et al.21Go showed that positioning of the LV lead in the lateral and postero-lateral coronary veins was associated with significant improvement in the functional capacity and greater improvement in the LV function when compared with the anterior coronary vein location. Heist et al.20Go analysed the effect of a larger horizontal interlead distance, whereby especially the interlead distance on the lateral X-ray influenced acute haemodynamics. No information, however, over objective long-term response is available. We could now demonstrate that this simple parameter can be used to predict response to biventricular stimulation. The vertical interlead difference between RV and LV, neither frontal nor lateral X-ray, was not of significance with regard to response rate. This coincides with the acute haemodynamic results found by Gold et al.22Go

Bax et al.23Go,24Go were the first to determine that diminishing of the septal-to-lateral delay by biventricular pacing was associated with response to CRT. In analogy with our results, they found that the septal-to-lateral delay significantly decreased with CRT. In contrast to our results, Gasparini et al.25Go could not find a significant difference in lead positioning and amount of clinical responders. It should be noted, however, that they found a significant correlation with an increase in LVEF, which, in several studies,13Go was correlated with LV remodelling and patient outcome (in contrast to clinical parameters).

Influence of right ventricular lead localization
In our population, non-responders more frequently had the RV lead localized in the RV outflow tract (RVOT); this observation is in accordance with the results found by Van Gelder et al.,26Go who found a significant difference in LV dP/dt max in 82 patients with biventricular pacing with placement of the RV lead in the apex being superior to placement in the septal wall. Therefore, it should be taken into account that this difference disappeared after V-V optimization. Possibly, a larger interlead separation is created by placing the RV lead in the apex.20Go

Dyssynchrony after implantation
Responders had a significantly larger decrease in the intraventricular mechanical delay after implantation of the CRT. Even so, positioning of the LV lead in the posterior position led to a greater decrease of the septal-to-lateral delay. The finding that the intraventricular mechanical delay decreases in responders in contrast to the non-responders is in accordance with results found by others.23Go,24Go The fact, however, that positioning of the LV lead in the posterior position more frequently was associated with a decrease of intraventricular mechanical delay has never been described previously.

Predictors for response
In the present study, we found that predictors for response were in addition to a large horizontal interlead distance on the lateral thoracic X-ray: a septal-to-lateral delay >60 ms, NICMP, a smaller LVEDD, the use of an ACE inhibitor, and no tricuspid valve regurgitation. These results are in accordance with results found by others.10Go,12Go,27Go Several studies have proven that patients with NICMP have a better chance for response to CRT than those with ischaemic cardiomyopathy.28Go–31Go Sogaard et al.28Go found a difference in contraction delay between ischaemic and non-ischaemic patients with the greatest contraction delay in the lateral and posterior LV walls for NICMP and in the septum and inferior walls for those with ischaemic cardiomyopathy.28Go Possibly, this difference in conduction delay could explain the influence of lead positioning. Further studies have shown that positioning of the LV lead in previous scar tissue is associated with non-response.29Go,30Go In accordance with our results, Richardson et al.27Go found that patients with non-ischaemic cardiomyopathy responded more frequently to CRT. Bax et al.12Go found that a septal-to-lateral delay of >60 ms is predictive for response to CRT, which we could confirm this in our study.

Limitations
The main limitation is the relatively small number of patients, partly due to missing data due to relocation of patients or death prior to 6 months of follow-up and therefore not included in the analysis. This limits the power to adjust for multiple variables.


    Conclusion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
The present study highlights that lead positioning is predictive for response to CRT. Larger interlead distance on the lateral thoracic X-ray, associated with the positioning of the LV lead in the posterior position, is associated with response after 6 months of follow-up. Furthermore, diminishing the septal-to-lateral delay is predictive for response.


    Funding
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
D.J.V.V. and I.C.V.G. received financial support for research from Medtronic, Boston Scientific, St Jude Medical and Biotronik.

Conflict of interest: D.J.V.V. is currently conducting research with Medtonic and has received consultancy fees from Medtronic. I.C.V.G. has received research grants from Medtronic, Biotronik, Boston Scientific and St Jude Medical.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Conclusion
 Funding
 References
 
[1] Manolis AS. Cardiac resynchronization therapy in congestive heart failure: ready for prime time? Heart Rhythm (2004) 1:355–63.[CrossRef][Web of Science][Medline]

[2] Leclercq C, Walker S, Linde C, Clementy J, Marshall AJ, Ritter P, et al. Comparative effects of permanent biventricular and right-univentricular pacing in heart failure patients with chronic atrial fibrillation. Eur Heart J (2002) 23:1780–7.[Abstract/Free Full Text]

[3] Cazeau S, Leclercq C, Lavergne T, Walker S, Varma C, Linde C, et al. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med (2001) 344:873–80.[Abstract/Free Full Text]

[4] Auricchio A, Stellbrink C, Sack S, Block M, Vogt J, Bakker P, et al. Long-term clinical effect of hemodynamically optimized cardiac resynchronization therapy in patients with heart failure and ventricular conduction delay. J Am Coll Cardiol (2002) 39:2026–33.[Abstract/Free Full Text]

[5] Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med (2002) 346:1845–53.[Abstract/Free Full Text]

[6] Higgins SL, Hummel JD, Niazi IK, Giudici MC, Worley SJ, Saxon LA, et al. Cardiac resynchronization therapy for the treatment of heart failure in patients with intraventricular conduction delay and malignant ventricular tachyarrhythmias. J Am Coll Cardiol (2003) 42:1454–9.[Abstract/Free Full Text]

[7] Young JB, Abraham WT, Smith AL, Leon AR, Lieberman R, Wilkoff B, et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure: the MIRACLE ICD Trial. JAMA (2003) 289:2685–94.[Abstract/Free Full Text]

[8] Auricchio A, Stellbrink C, Butter C, Sack S, Vogt J, Misier AR, et al. Clinical efficacy of cardiac resynchronization therapy using left ventricular pacing in heart failure patients stratified by severity of ventricular conduction delay. J Am Coll Cardiol (2003) 42:2109–16.[Abstract/Free Full Text]

[9] Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, et al. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med (2004) 350:2140–50.[Abstract/Free Full Text]

[10] Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med (2005) 352:1539–49.[Abstract/Free Full Text]

[11] Gregoratos G, Abrams J, Epstein AE, Freedman RA, Hayes DL, Hlatky MA, et al. ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices—summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). J Am Coll Cardiol (2002) 40:1703–19.[Free Full Text]

[12] Bax JJ, Abraham T, Barold SS, Breithardt OA, Fung JW, Garrigue S, et al. Cardiac resynchronization therapy: part 1—issues before device implantation. J Am Coll Cardiol (2005) 46:2153–67.[Abstract/Free Full Text]

[13] Yu CM, Bleeker GB, Fung JW, Schalij MJ, Zhang Q, van der Wall EE, et al. Left ventricular reverse remodeling but not clinical improvement predicts long-term survival after cardiac resynchronization therapy. Circulation (2005) 112:1580–6.[Abstract/Free Full Text]

[14] Sahn DJ, DeMaria A, Kisslo J, Weyman A. Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements. Circulation (1978) 58:1072–83.[Abstract/Free Full Text]

[15] Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, et al. Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr (1989) 2:358–67.[Medline]

[16] Bleeker GB, Bax JJ, Fung JW, van der Wall EE, Zhang Q, Schalij MJ, et al. Clinical versus echocardiographic parameters to assess response to cardiac resynchronization therapy. Am J Cardiol (2006) 97:260–3.[CrossRef][Web of Science][Medline]

[17] Blanc JJ, Etienne Y, Gilard M, Mansourati J, Munier S, Boschat J, et al. Evaluation of different ventricular pacing sites in patients with severe heart failure: results of an acute hemodynamic study. Circulation (1997) 96:3273–7.[Abstract/Free Full Text]

[18] Leclercq C, Cazeau S, Le Breton H, Ritter P, Mabo P, Gras D, et al. Acute hemodynamic effects of biventricular DDD pacing in patients with end-stage heart failure. J Am Coll Cardiol (1998) 32:1825–31.[Abstract/Free Full Text]

[19] Butter C, Auricchio A, Stellbrink C, Fleck E, Ding J, Yu Y, et al. Effect of resynchronization therapy stimulation site on the systolic function of heart failure patients. Circulation (2001) 104:3026–9.[Abstract/Free Full Text]

[20] Heist EK, Fan D, Mela T, Arzola-Castaner D, Reddy VY, Mansour M, et al. Radiographic left ventricular–right ventricular interlead distance predicts the acute hemodynamic response to cardiac resynchronization therapy. Am J Cardiol (2005) 96:685–90.[CrossRef][Web of Science][Medline]

[21] Rossillo A, Verma A, Saad EB, Corrado A, Gasparini G, Marrouche NF, et al. Impact of coronary sinus lead position on biventricular pacing: mortality and echocardiographic evaluation during long-term follow-up. J Cardiovasc Electrophysiol (2004) 15:1120–5.[CrossRef][Web of Science][Medline]

[22] Gold MR, Auricchio A, Hummel JD, Giudici MC, Ding J, Tockman B, et al. Comparison of stimulation sites within left ventricular veins on the acute hemodynamic effects of cardiac resynchronization therapy. Heart Rhythm (2005) 2:376–81.[CrossRef][Web of Science][Medline]

[23] Bax JJ, Molhoek SG, van Erven L, Voogd PJ, Somer S, Boersma E, et al. Usefulness of myocardial tissue Doppler echocardiography to evaluate left ventricular dyssynchrony before and after biventricular pacing in patients with idiopathic dilated cardiomyopathy. Am J Cardiol (2003) 91:94–7.[CrossRef][Web of Science][Medline]

[24] Bleeker GB, Mollema SA, Holman ER, Van de Veire N, Ypenburg C, Boersma E, et al. Left ventricular resynchronization is mandatory for response to cardiac resynchronization therapy: analysis in patients with echocardiographic evidence of left ventricular dyssynchrony at baseline. Circulation (2007) 116:1440–8.[Abstract/Free Full Text]

[25] Gasparini M, Mantica M, Galimberti P, Bocciolone M, Genovese L, Mangiavacchi M, et al. Is the left ventricular lateral wall the best lead implantation site for cardiac resynchronization therapy? Pacing Clin Electrophysiol (2003) 26:162–8.[CrossRef][Medline]

[26] Van Gelder BM. Hemodynamic effect of RV apex versus RV septum pacing in a monoventricular and biventricular configuration in patients with heart failure. Europace (2005) 7:288.[Abstract/Free Full Text]

[27] Richardson M, Freemantle N, Calvert MJ, Cleland JG, Tavazzi L. Predictors and treatment response with cardiac resynchronization therapy in patients with heart failure characterized by dyssynchrony: a pre-defined analysis from the CARE-HF trial. Eur Heart J (2007) 28:1790–2.[Free Full Text]

[28] Sogaard P, Egeblad H, Pedersen AK, Kim WY, Kristensen BO, Hansen PS, et al. Sequential versus simultaneous biventricular resynchronization for severe heart failure: evaluation by tissue Doppler imaging. Circulation (2002) 106:2078–84.[Abstract/Free Full Text]

[29] Gasparini M, Mantica M, Galimberti P, Genovese L, Pini D, Faletra F, et al. Is the outcome of cardiac resynchronization therapy related to the underlying etiology? Pacing Clin Electrophysiol (2003) 26:175–80.[CrossRef][Medline]

[30] Ypenburg C, Schalij MJ, Bleeker GB, Steendijk P, Boersma E, Dibbets-Schneider P, et al. Impact of viability and scar tissue on response to cardiac resynchronization therapy in ischaemic heart failure patients. Eur Heart J (2006) 28:33–41.[CrossRef][Web of Science][Medline]

[31] Mangiavacchi M, Gasparini M, Faletra F, Klersy C, Morenghi E, Galimberti P, et al. Clinical predictors of marked improvement in left ventricular performance after cardiac resynchronization therapy in patients with chronic heart failure. Am Heart J (2006) 151:477.[Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
H. R. Bonakdar, M. V. Jorat, A. F. Fazelifar, A. Alizadeh, N. Givtaj, N. Sameie, A. Sadeghpour, and M. Haghjoo
Prediction of response to cardiac resynchronization therapy using simple electrocardiographic and echocardiographic tools
Europace, October 1, 2009; 11(10): 1330 - 1337.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/11/1313    most recent
eun208v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Buck, S.
Right arrow Articles by Van Gelder, I. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buck, S.
Right arrow Articles by Van Gelder, I. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?