Europace Advance Access originally published online on June 4, 2007
Europace 2007 9(9):844-847; doi:10.1093/europace/eum116
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CONGENITAL HEART DISEASE
Sinus node function in children with congenital complete atrioventricular block
1 Beatrix Children's Hospital, Division of Pediatric Cardiology, University Medical Center Groningen, University of Groningen, Hanzeplein 1, PO Box 30001, 9700 RB Groningen, The, Netherlands
Manuscript submitted 21 March 2007. Accepted after revision 3 May 2007.
* Corresponding author. Tel: +31 50 3612800; fax: +31 50 3614235. E-mail address: m.t.e.bink-boelkens{at}xs4all.nl tgbeauf{at}xs4all.nl
| Abstract |
|---|
|
|
|---|
Aims Children with congenital complete atrioventricular block (CCAVB) often need pacemaker therapy. In these children, it may be preferable to use single-lead VDD pacing, but for VDD pacing a normal sinus node function is required. Our aim was to study sinus node function in children with CCAVB.
Methods and results We longitudinally evaluated sinus rate in 36 children with CCAVB and normal anatomy of the heart. The rate of sinus rhythm on a 12-lead ECG, in Holter recordings, and exercise tests were evaluated at regular intervals. Age at the first visit of the children was 2.5±3.3 years (mean±SD). Follow-up was 10.6±7.3 years. The rate of sinus rhythm on a 12-lead ECG was at every age within the normal values for age (e.g. 0–1 year: 153±24 bpm, and 17–18 years: 76±4 bpm). Lowest and highest sinus rates in the Holter recordings were normal. During exercise, mean sinus rate in the total group of children increased from 92±8 at rest to 171±9 bpm at maximal exercise.
Conclusion We conclude that sinus node function is normal in children with CCAVB. Because of the normal increase in sinus rate during exercise, a single-lead VDD pacemaker can be safely implanted in these children.
Key Words: Arrhythmias, Complete heart block, Congenital, Pacemakers, Paediatrics, Sinus node
| Introduction |
|---|
|
|
|---|
Children with a congenital complete atrioventricular block (CCAVB) will need pacemaker implantation early in life. Some need a pacemaker already in infancy, but the majority in adolescence or early in adulthood. Especially, since Michaëlsson et al.1
One of the risks of endocardial pacing is the development of thrombosis and obstruction of the subclavian veins. The incidence of abnormal venography, mentioned in the literature, varies from 23 to 64%. Total occlusion was found in 6–25%.2
–7
Risk factors, from the literature, for venous occlusion are contradictory and unclear, although some authors found a relation between multiple leads and obstruction and between the cross-sectional area of leads indexed to body surface and obstruction.6
,7
To save the subclavian veins, we are in favour of starting with epicardial pacing leads and when endocardial pacing is preferred or needed a single lead should be considered. That means a VVIR or VDD pacing mode. VDD pacing is preferable because of the AV synchrony and the normal heart rate response to physiological stress. Single-lead VDD pacing has been proved to be safe and reliable in adults as well as in children.8
,9
A prerequisite for VDD pacing is a normal sinus node function. However, there is only sporadic information about sinus node function in patients with CCAVB.
Menon et al.10
found a diminished rate response of the sinus node during exercise in 3 out of 28 patients with CCAVB. Pathologists showed small abnormalities of the sinus node in the hearts of some patients with CCAVB because of anti-Ro antibodies.11
,12
The aim of our study was to answer the question if children with CCAVB have a normal sinus node function. Therefore, we longitudinally evaluated all children referred to our hospital with CCAVB and a normal heart since 1976 by yearly ECG, 24-h Holter recording and (if old enough) exercise test.
| Methods |
|---|
|
|
|---|
Patients
Thirty-six children with CCAVB and normal anatomy of the heart were admitted to our hospital since 1976. All parents provided informed consent for clinical evaluation. Complete AV block was defined as complete dissociation of the P wave and the QRS complex with a higher atrial than ventricular rate. Mean age of the 36 children (25 females and 11 males) at the time of diagnosis was 2.5±3.3 years (mean±SD) with a range from in utero at a gestational age of 20 weeks to 14.2 years. RoSSA antibodies were present in 9 of the 17 children tested for this. Seventeen children were treated with a pacemaker.
Monitoring parameters
We longitudinally evaluated the children during follow-up by history, in particular of complaints like syncope or exercise intolerance, physical examination, ECG, 24-h Holter recording, and an exercise study. Only values obtained before pacemaker therapy were included.
ECG
In a 12-lead ECG (rest; supine position), P rate (=sinus rhythm) and QRS rate (=AV nodal escape rhythm) were evaluated and compared to normal values.13
P/QRS ratios were calculated by dividing P rate by QRS rate.
Holter recording
In the Holter, lowest, mean, and highest sinus rates and lowest, mean, and highest QRS rates were evaluated yearly and compared to normal values.14
Also P/QRS ratios were calculated.
Exercise test
After the age of 7 years, the lowest and highest sinus and QRS rates during an exercise test (bicycle) were measured two-yearly. Also P/QRS ratios were calculated.
| Results |
|---|
|
|
|---|
Patients
Age at the first visit of the children was 2.5±3.3 years (mean±SD). Follow-up was 10.6±7.3 years.
12-lead ECG
The P rate on a 12-lead ECG at rest was at every age within the normal values for age according to Davignon (Figure 1A; e.g. 0–1 year: 153±24 bpm, and 17–18 years: 76±4 bpm). From the age of 4 years, the sinus rate is between the 5th and 50th percentile of normal. The QRS rate is shown in Figure 1B. P/QRS ratio was greater than 2.0 at age <3 years; thereafter less than 2.0 (Figure 1C).
|
Holter
Lowest, mean, and highest P rates in a Holter recording were normal (Figure 2A). Lowest and highest QRS rates are shown in Figure 2B. P/QRS ratios of lowest and highest heart rates did not alter with ageing during childhood.
|
Exercise study
During exercise, mean sinus rate in the total group of children increased from 92±8 at rest to 171±9 bpm at maximal exercise. Mean QRS rate increased from 51±4 at rest to 90±8 bpm at maximal exercise. P/QRS ratios are similar as found on the Holter recording. The maximal reached exercise capacity was 85.8±8.9% of the normal value for age and length.15
| Discussion |
|---|
|
|
|---|
Sinus node function
We found a, totally, normal sinus node function on rest ECG and 24-h Holter monitoring in this longitudinal study of 36 children with CCAVB with a follow-up of 10.6±7.3 years. The maximal heart rate during exercise was only slightly below normal, but only 85.8±8.9% of the normal value for age and length of the maximal exercise capacity was reached. We assume that the maximal exercise capacity is lower in CCAVB because of a limitation in increase in AV nodal escape rate. If we take into account the lower exercise capacity, the maximal sinus rate at 100% exercise capacity will be as high as 199 bpm, which is normal.14
Escape rhythm
This study gave us the opportunity to study the natural history of the AV nodal escape rhythm. This gives information to determine if the escape rhythm of future patients is within normal limits at rest, during daily activities, or at maximal exercise. The decline in QRS rate over the ages follows the pattern of normal sinus rhythm. The P/QRS ratio is mostly
2 except for the first 3 years.
Pacemaker therapy
Life-long pacing obliges the (paediatric) cardiologist to choose the pacing methods very carefully to prevent major problems and risks for the future. Comparison of single-lead (VVI, VDD) pacing with dual chamber pacing showed a significantly higher operation time and complication rate in DDD pacing. There were no differences between VVI and VDD pacing.9
Furthermore, some authors found a relation between the vein obstruction and the number of pacing leads or the cross-sectional area of leads indexed to body surface.6
,7
Single-lead VDD pacing is preferable to VVI(R) pacing because of the restoration of AV synchrony and the physiologic rate response. Complete dislodgement of the free floating atrial dipole in VDD pacing is rare in adults and the risk is lower than of atrial lead malfunction in DDD pacemakers.9
In children, a small amount of extra lead is left in the atrium to allow for somatic growth. This could increase the risk of atrial malsensing later, but in the majority AV synchrony remains intact. If there will be loss of atrial sensing in the long-term, than the VVIR mode of pacing can be programmed and the system can, if needed, always be updated to a DDD system by placement of an extra atrial lead. An other argument to limit the number of pacing leads is the fact that, although the experience in intravascular lead extraction has increased considerably over the years, it continues to be associated with the risk of major complications.16
Conclusion
We conclude that sinus node function is normal in children with CCAVB. Therefore, a single-lead VDD pacemaker can safely be implanted in these children and young adults. This is preferred over dual chamber pacing, in view of the long period of pacing ahead.
Conflict of interest: none declared
| References |
|---|
|
|
|---|
[1] Michaëlsson M, Jonzon A, Riesenfeld T. Isolated congenital complete atrioventricular block in adult life. Circulation (1995) 92:442–9.
[2] Do Carma da Costa SS, Neto AS, Costa R, Caldas JG, Filho MM. Incidence and risk factors of upper extremity deep vein lesions after permanent transvenous pacemaker implant: a 6-month follow-up prospective study. PACE (2002) 25:3101–6.
[3] Rozmus G, Daubert JP, Huang DT, Rosero S, Hall B, Francis C. Venous thrombosis and stenosis after implantation of pacemakers and defibrillators. J Interv Card Electrophysiol (2005) 13:9–19.[CrossRef][Web of Science][Medline]
[4] Bracke F, Meijer A, van Gelder B. Venous occlusion of the access vein in patients referred for lead extraction: influence of patient and lead characteristics. PACE (2003) 26:1649–52.[Medline]
[5] Oginosawa Y, Abe H, Nakashima Y. The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads. PACE (2002) 25:1605–11.[Medline]
[6] Van Rooden CJ, Molhoek SG, Rosendaal FR, Schalij MJ, Meinders E, Huisman MV. Incidence and risk factors of early venous thrombosis associated with permanent pacemaker leads. J Cardiovasc Electrophysiol (2004) 15:1258–62.[CrossRef][Web of Science][Medline]
[7] Figa FH, McCrindle BW, Bigras JL, Hamilton RM, Gow RM. Risk factors for venous obstruction in children with transvenous pacing leads. PACE (1997) 20:1902–9.[Medline]
[8] Celiker A, Karakurt C, Karagoz T. Single-pass lead VDD pacing system in children and adolescents: report of twenty-four patients. Acta Cardiol (2006) 61:63–7.[CrossRef][Web of Science][Medline]
[9] Wiegand UKH, Bode F, Bonnemeier H, Eberhard F, Schlei M, Peters W. Long-term complication rates in ventricular, single lead VDD, and dual chamber pacing. PACE (2003) 26:1961–9.[Medline]
[10] Menon A, Silverman ED, Gow RM, Hamilton RM. Chronotropic competence of the sinus node in congenital complete heart block. Am J Cardiol (1998) 82:1119–21.[CrossRef][Web of Science][Medline]
[11] Ho SY, Esscher E, Anderson RH, Michaëlsson M. Anatomy of congenital complete heart block and relation to maternal anti-Ro antibodies. Am J Cardiol (1986) 58:291–4.[CrossRef][Web of Science][Medline]
[12] Lev M, Silverman J, Fitzmaurice FM, Paul MH, Cassels DE, Miller RA. Lack of connection between the atria and the more peripheral conduction system in congenital complete atrioventricular block. Am J Cardiol (1971) 27:481–90.[CrossRef][Web of Science][Medline]
[13] Davignon A. Normal ECG standards for infants and children. Pediatr Cardiol (1979/80) 1:123–31.[CrossRef]
[14] Nagashima M, Matsushima M, Ogawa A, Ohsuga A, Kaneko T, Yazaki T, et al. Cardiac arrhythmias in healthy children revealed by 24-hour ambulatory ECG monitoring. Pediatr Cardiol (1987) 8:103–8.[CrossRef][Web of Science][Medline]
[15] Washington RL, Bricker T, Alpert BS, Daniels SR, Deckelbaum RJ, Fisher EA, et al. Guidelines for exercise testing in the pediatric age group. Circulation (1994) 90:2166–79.
[16] Verma A, Witkoff BL. Intravascular pacemaker and defibrillator lead extraction: a state of the art review. Heart Rhythm (2004) 1:739–45.[CrossRef][Web of Science][Medline]
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
C. S. Chronister Congenital Complete Atrioventricular Block in a Young Man: A Case Study Crit. Care Nurse, October 1, 2009; 29(5): 45 - 56. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||