Skip Navigation


Europace Advance Access originally published online on March 16, 2007
Europace 2007 9(5):328-332; doi:10.1093/europace/eum019
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
9/5/328    most recent
eum019v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (7)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Haghjoo, M.
Right arrow Articles by Sadr-Ameli, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haghjoo, M.
Right arrow Articles by Sadr-Ameli, M. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2007. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org


PACEMAKER THERAPY

Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade

Majid Haghjoo*, Mohammad Hossein Nikoo, Amir Farjam Fazelifar, Abolfath Alizadeh, Zahra Emkanjoo and Mohammad Ali Sadr-Ameli

Department of Pacemaker and Electrophysiology, Rajaie Cardiovascular Medical and Research Center, Mellat Park, Vali-e-Asr Avenue, PO Box 15745-1341, Tehran 1996911151, Islamic Republic of Iran

Manuscript submitted 8 September 2006. Accepted after revision 5 January 2007.

* Corresponding author. Tel: +9821 2392 2931; fax: +9821 2204 8174. E-mail address: majid.haghjoo{at}gmail.com


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
Aim: Venous obstruction following transvenous device implantation rarely cause immediate clinical problems. When lead revision or device upgrade is indicated, venous obstruction become a significant challenge. The aim of this study was to determine the predictors of venous obstruction after transvenous device implantation, and to asess likely effects of antiplatelet/anticoagulant drugs in preventing venous thrombosis.

Methods and results: Between March 2005 and July 2006, contrast venography was performed in 100 patients who were candidates for generator change, lead revision, or device upgrade. Vessel patency was graded as either completely obstructed, partially obstructed (>70%), or patent. The incidence of venous obstruction was 26%, with 9% of patients having total obstruction and 17% of patients exhibiting partial obstruction. No statistically significant differences between obstructed and non-obstructed patients were seen for age, sex, indication for device implantation, atrial fibrillation, cardiothoracic ratio, insulation material, operative technique, device type, and manufacturer (all Ps > 0.05). In a univariate analysis, multiple leads (P = 0.033), and presence of dilated cardiomyopathy (P = 0.036) were associated with higher risk of venous obstruction, whereas anticoagulant/antiplatelet therapy (P = 0.047) significantly reduced incidence of venous obstruction. Multivariate logistic regression analysis showed that only number of the leads (P = 0.039, OR: 2.22, and 95% CI: 1.03–4.76) and antiplatelet/anticoagulant therapy (P = 0.044, OR: 2.79, and 95% CI: 0.98–7.96) were predictors of venous obstruction.

Conclusion: Total or partial obstruction of the access veins occurs relatively frequently after pacemaker or ICD implantation. Multiple pacing or ICD leads are associated with an increased risk of venous obstruction, whereas antiplatelet/anticoagulant therapy appears to have a preventive effect on development of access vein thrombosis.

Key Words: Venous obstruction, Predictors, Pacemaker, Implantable cardioverter-defibrillator, Venography


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
There are growing numbers of follow-up procedures, such as generator change, lead revision, and device upgrade in patients with pacemakers and implantable cardioverter-defibrillators (ICD). Obstruction of the access vein is a well-known complication of both permanent pacemaker and ICD implantation.1Go–4Go These obstructions are most commonly asymptomatic (with incidence of 30–50%) and symptomatic cases are seen infrequently (1–3%).5Go Presence of obstruction in the access vein can make follow-up procedures difficult or impossible.

Although numerous studies have tried to determine predictors of venous obstruction following transvenous device implantation, no risk factors were defined.3Go,4Go,6Go–9Go In addition, protective effects of antiplatelet/anticoagulant drugs on venous obstruction have not been demonstrated.10Go Therefore, to determine predictors of venous obstruction after transvenous device implantation and to asess likely effects of antiplatelet/anticoagulant drugs in preventing venous thrombosis, the preoperative venography of patients referred for pacemaker or ICD generator change, lead revision, and device upgrade were reviewed.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
Study population
Between March 2005 and July 2006, 100 consecutive patients admitted to our institution for their first pulse generator replacement, lead revision, or device upgrade were enrolled in the study. The study was approved by the local Ethics Committee, and written informed consent was obtained from all the patients. Included were 53 men and 47 women with a mean age of 62.76 ± 19.40 years (range 10–89 years). Three patients were not included in the study because of prior history of contrast medium hypersensitivity (n = 2) and renal dysfunction (Cr = 2.5 mg/dL,=1). Contrast venography was performed in all patients. No patient had a history of hypercoagulable state or exhibited symptoms or clinical signs of venous obstruction at the time of study. Indication for original device implantation was complete atrioventricular (AV) block in 61%, second-degree AV block in 3%, sick sinus syndrome in 18%, ventricular tachycardia or fibrillation in 13%, and refractory heart failure in 5%. Underlying diseases were coronary artery disease (35%), dilated cardiomyopathy (4%), hypertrophic cardiomyopathy (3%), hypertension (10%), diabetes (1%), valvular heart disease (5%), and congenital heart disease (10%). History of aspirin and warfarin therapy was present in 50 and 11 patients, respectively. No other antiplatelet drugs including clopidogrel, ticlopidine, and dipyridamole were taken by the patients. At the time of study, baseline rhythm was sinus in 87 patients and the remainder (n = 13) had atrial fibrillation. There were 83 patients with pacemakers and 17 with an implantable cardioverter-defibrillators (ICD). Subclavian vein puncture technique was used for lead insertion in 59 patients and cephalic vein cutdown in 41 patients. All leads were in place for an average of 8.09 ± 4.48 years. Lead insulation material consisted of silicone rubber in 92 patients and polyurethane in eight patients. Patient characteristics are summarized in Table 1.


View this table:
[in this window]
[in a new window]

 
Table 1 Patient characteristics

 
Venography
From March 2005, contrast venography was performed for all patients before generator change, lead revision, and device upgrade in our institution. Venography was performed by placing a 16-gauge canulla in a peripheral arm vein on the side to be studied, and 20–30 mL of a contrast medium (Urografin 76%, Schering AG, Berlin, Germany) was injected. Contrast medium flow in the cephalic, axillary, subclavian and brachiocephalic veins, as well as the superior vena cava was observed and recorded by cineangiography.

The venograms were reviewed by two electrophysiologists, and vessel patency was graded as either completely obstructed (clear interruption of contrast flow), partially obstructed (>70% compared with the distal site of the vessel in association with venous collateral),4Go,7Go or patent (Figure 1). Of 100 patients, transvenous leads were implanted from the right pectoral side in 61 patients, and from the left pectoral side in the remaining 39 patients.


Figure 1
View larger version (81K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 (A) Partial obstruction of right subclavian vein (white arrow) with extensive collateral circulation. (B) Complete obstruction of left subclavian vein (white arrow). Note that there is well-developed cervical collateral formation bypassing the site of obstruction.

 
Statistical analysis
Continuous data are presented as mean ± SD and ranged when appropriate. Continuous variables were compared by Student's t-test in case of normal distribution. Otherwise, the non-parametric test Mann–Whitney U was used. For categorical data, {chi}2 analysis was used, and the Fisher exact test for cell count less than five. We used binary logistic regression analysis with forward selection method to find the potential predictors of venous obstruction after transvenous device implantation. We included all the parameters which showed a P value <0.1 during bivariable correlation into our binary logistic regression analysis model. Hosmer–Lemeshow statistics where used to confirm model fitness for the data. A P value <0.05 was defined as statistically significant. The software SPSS version 13.0 (SPSS Inc., Chicago, IL, USA) was used for statistical analysis.


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
A total of 100 patients (53 men, mean age 62.76 ± 19.40 years) was included in this study (Table 1). Device systems, which were in place before obtaining contrast venography, comprised single-chamber pacemakers (n = 55), dual-chamber pacemakers (n = 22), biventricular pacemakers (n = 6), single-chamber ICDs (n = 7), dual-chamber ICDs (n = 5), and biventricular ICDs with an atrial lead (n = 5). All ICD leads were dual-coils. Procedures performed after venography consisted of generator change (n = 70), lead revision (n = 17), and system upgrade (n = 11). Change to an epicardial system was necessary only in the remaining two patients.

Findings of contrast venography
No abnormality was found in 74% of patients. The remaining 26% exhibited venous obstruction of various degrees. Of 100 patients with venography, 9 (9%) had complete venous obstruction and another 17 (17%) had partial obstruction. Well-developed collateral circulation was observed in all patients with complete or partial obstruction. All patients were asymptomatic and no abnormalities were found on physical examination. The locations of venous obstruction (Figure 2) were left brachiocephalic vein in one patient (partial obstruction), left subclavian vein in 13 patients (complete obstruction in seven patients and partial obstruction in six patients), right subclavian vein in 10 patients (complete obstruction in two patients and partial obstruction in eight patients), right cephalic vein in one patient (complete obstruction), and superior vena cava in one patient (partial obstruction). Side effects of contrast venography were not observed in any of the 100 patients.


Figure 2
View larger version (13K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 2 Schematic representation demonstrating locations of venous obstruction. RSCV, right subclavian vein; LSCV, left subclavian vein; RCV, right cephalic vein; RBCV, right brachiocephalic vein; LBCV, left brachiocephalic vein; RIJV, right internal jugular vein; LIJV, left internal jugular vein; SVC, sperior vena cava.

 
Predictors for venous obstruction
Numerous patient-related and device-related risk factors were investigated and compared between patients with venous obstruction (Group I) and those with patent venous anatomy (Group II). There were no statistically significant differences in terms of age (P = 0.90), sex (P = 0.42), baseline rhythm (P = 0.79), indication for endovenous device implantation (P = 0.17), left ventricular ejection fraction (P = 0.24), cardiothoracic ratio (P = 0.81), and hypertension (P = 0.08). Also, no significant differences between Group I and Group II were seen for type of device (pacemaker vs. ICD, P = 0.13), total lead duration (P = 0.14), insulation material (P = 0.44), site of implantation (left vs. right, P = 0.07), route of entry (cephalic vs. subclavian approach, P = 0.53), and device manufacturer (P = 0.94). Furthermore, the univariate analysis showed statistically significant differences in the incidence of venous obstruction in terms of number of leads (Group I: mean 1.9, range 1–4 vs. Group II: mean 1.1, range 1–2, P = 0.033), history of antiplatelet/anticoagulant therapy (P = 0.047), and presence of dilated cardiomyopathy (P = 0.036) (Table 2). There was no statistically significant difference between those on aspirin and those on warfarin, in terms of protection from venous obstruction (P = 0.48). However, the numbers were not adequate to permit any definite conclusions. In multivariate logistic regression analysis, only the number of leads (P = 0.039, OR: 2.22, and 95% CI: 1.03–4.76) and antiplatelet/anticoagulant therapy (P = 0.044, OR: 2.79, and 95% CI: 0.98–7.96) were predictors of venous obstruction after transvenous device implantation (Table 3). Subgroup analysis in patients with pacemakers indicated that both the number of the leads (P = 0.046, OR: 2.01, and 95% CI: 0.97–3.65) and antiplatelet/anticoagulant therapy (P = 0.038, OR: 3.30, and 95% CI: 0.98–11.06) were predictors, whereas the number of the leads was the only predictor of venous obstruction after ICD implantation (P = 0.019, OR: 4.89, and 95% CI:1.06–22.55) (Table 3).


View this table:
[in this window]
[in a new window]

 
Table 2 Univariate comparison of risk factors for venous obstruction after long-term pacemaker or ICD

 


View this table:
[in this window]
[in a new window]

 
Table 3 Multivariate comparison of risk factors for venous obstruction after pacemaker or ICD

 

    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
Main findings
The present study evaluates the predictors of venous obstruction following long-term transvenous pacemaker or ICD implantation. The main findings of our study include: (i) Multiple leads (both pacemaker and ICD lead) are associated with an increased risk of venous obstruction. (ii) Antiplatelet/anticoagulant therapy for other reasons than transvenous lead is associated with significant preventive effect on development of the access vein thrombosis. (iii) Total or partial obstruction of the access veins occurs relatively frequently after pacemaker or ICD implantation. The incidence of total obstruction and partial obstruction was 9 and 17%, respectively. (iv) This study demonstrates that pacemaker and ICD patients have a similar risk of lead-related venous obstruction.

Predictors of venous obstruction after transvenous pacemaker or ICD implantation
Despite many years of experience with transvenous pacing or defibrillator systems, no studies have been able to identify clear risk factors that lead to venous stenosis.3Go,4Go,6Go–9Go Neither the hardware (total lead duration, lead size, number, and insulation material) nor the operative technique (cephalic vs. subclavian approach or right vs. left pectoral implantation) appears to affect the rate of venous complications in previous studies.6Go The same is true of underlying disease, age, sex, smoking, and history of atrial fibrillation.3Go

Among the multiple patient-related (age, sex, underlying disease, indication of pacemaker or ICD implantation, baseline rhythm, and cardiothoracic ratio) and device-related factors (pacemaker vs. ICD, total lead duration, insulation material, site of implantation, route of entry, and device manufacturer) entered in our study, only two predictors (number of the implanted leads and antiplatelet/anticoagulant therapy) were identified for the occurrence of venous obstruction.

Although it has been stated that if too many leads are present the resultant reaction has a high probability of obstructing the vein, this has not been well substantiated in the literature.11Go,12Go None of the published studies (clinical venographic and clinical only) described a higher incidence of occlusion with multiple leads.3Go,7Go–10Go,13Go–17Go Only Pauletti et al.,18Go in an isotope study, reported a significantly higher incidence of occlusion in a population with multiple leads compared with single lead (26 vs. 8%, P < 0.05). In this study, obstruction was not directly visualized but its presence derived from the presence of collaterals and progressive increasing isotope activity locally. To the best of our knowledge, the present study is the only venographic study in which there is a significant correlation between number of leads and venous thrombosis after endovenous pacemaker or ICD implantation both in univariate and multivariate analyses (Table 3). These controversial results may be explained by differences in number of patients, mean time from implant, definition of venous obstruction, and characteristics of study population.

In view of endothelial trauma caused by lead insertion, extension of thrombus from ligated vein, and post-operative hypercoagulable state,1Go it is expected that antiplatelet/anticoagulant therapy could be useful to prevent thrombus formation following transvenous device implantation. This issue had been investigated by Goto et al. in a retrospective study.10Go However, these investigators could not find the efficacy of prophylactic administration of anticoagulant and antiaggregant drugs to prevent venous thrombosis after transvenous pacemaker implantation. Our data demonstrate that antiplatelet/anticoagulant therapy (for other reasons than pacemaker lead) had a significant antithrombotic effect in patients with endovenous pacemakers. Similarly, Seeger et al. described the beneficial effects of post-operative prophylactic heparin in their prospective study.19Go Number of patients receiving antiplatelet/anticoagulant drugs (42 vs. 61%) and type of the administered drug (mainly dipyridamole in the Goto study vs. aspirin in our cases) may explain dicrepancies between the results of Goto et al. study and the present study. We could not demonstrate efficacy of antiplatelet/anticoagulant drugs in preventing venous thrombosis after ICD implantation. We think that small number of patients with ICD is responsible for this observation.

Among the patients who were candidate for transvenous device implantation, Oginosawa et al. showed that cardiothoracic ratio was significantly greater in patients with venous occlusions than patients with patent venous anatomy.20Go However, the predictive role of cardiothoracic ratio was not assessed in a multivariate analysis. We could not confirm this finding in our study. These discrepancies may be explained by the fact that Oginosawa et al.20Go evaluated the patients at the time of their first device implantations, whereas our study investigated the venous obstruction among the patients who were candidates for repeat device procedures.


    Study limitations
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
The present study must be interpreted in the face of certain limitations. This study was a retrospective analysis and a selection bias was introduced by evaluating a population of patients at the time of repeat device procedures. However, prospective data acqusition limited untoward effects of retrospective analysis. The present study was also limited by the fact that the incidence of venous obstruction prior to implanting the leads was not been investigated. Some previous reports have shown that the incidence of venous obstruction before pacing lead implantation is not rare.3Go However, in view of successful initial implantation of all transvenous leads, no preexisting complete obstructions should be expected in the present study. Among the patients in whom results of pre-procedure venography were available (n = 32), no partial obstruction was reported. Another limitation is that the study is a single centre experience.

Conclusions and clinical implications
Various degrees of venous obstruction are relatively frequent following permanent pacemaker or ICD implantation, occurring in nearly one-fourth of patients who are candidate for generator change, lead revision, or device upgrade. However, venous access is possible in most cases either for lead revision or implantation of additional leads, with the goal of upgrading a preexisting system. On the basis of our findings, we recommend venography in all patients who present for pacemaker or ICD generator change associated with signs of lead injury or who need implantation of additional leads for upgrading to dual-chamber or biventricular systems.

Before any recommendation regarding the administration of antiplatelet/anticoagulant therapy in patients with endovenous device implantation, confirmation of antithrombotic effects of aspirin and warfarin in a prospective and randomized study is reasonable to determine practice guidelines. The role of superfluous lead extraction in preventing venous thrombosis should also be further studied.


    Acknowledgements
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
We would like to thank Mr Nikpoor and Mr Lotfi for performing contrast venography and storage of data.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Study limitations
 Acknowledgements
 References
 
[1] Spittell PC and Hayes DL. Venous complications after insertion of a transvenous pacemaker. Mayo Clin Proc 1992; 67: 258–65.[Web of Science][Medline]

[2] Stoney WS, Addlestone RB, Alford WC Jr, Burrus GR, Frist RA, Thomas CS Jr. The incidence of venous thrombosis following long term transvenous pacing. Ann Thorac Surg 1976; 22: 166–70.[Abstract]

[3] Oginosawa Y, Abe H, Nakashima Y. The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads. Pacing Clin Electrophysiol 2002; 25: 1605–11.[CrossRef][Medline]

[4] Lickfett L, Bitzen A, Arepally A, Nasir K, Wolpert C, Jeong KM, et al. Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography in patient presenting for their first elective ICD generator replacement. Europace 2004; 6: 25–31.[Abstract/Free Full Text]

[5] Williams EH, Tyers GF, Shaffer CW. Symptomatic deep venous thrombosis of the arm associated with permanent transvenous pacing electrodes. Chest 1978; 73: 613–5.[Web of Science][Medline]

[6] Rozmus G, Daubert JP, Huang DT, Rosero S, Hall B, Francis C. Venous thrombosis and stenosis after implantation of pacemakers and defibrillators. J Interv Card Electrophysiol 2005; 13: 9–19.[CrossRef][Web of Science][Medline]

[7] Bar-Cohen Y, Berul CI, Alexander ME, Fortescue EB, Walsh EP, Triedman JK, et al. Age, size, and lead factors alone do not predict venous obstruction in children and young adults with transvenous lead systems. J Cardiovasc Electrophysiol 2006; 17: 754–9.[CrossRef][Web of Science][Medline]

[8] Bracke F, Meijer A, van Gelder B. Venous occlusion of the access vein in patients referred for lead extraction: influence of patient and lead characteristics. Pacing Clin Electrophysiol 2003; 26: 1649–52.[CrossRef][Medline]

[9] Antonelli D, Turgeman Y, Kaveh Z, Artoul S, Rosenfeild T. Short-term thrombosis after transvenous permanent pacemaker insertion. Pacing Clin Electrophysiol 1989; 12: 280–2.[CrossRef][Medline]

[10] Goto Y, Abe T, Sekine S, Sakurada T. Long-term thrombosis after transvenous permanent pacemaker implantation. Pacing Clin Electrophysiol 1998; 21: 1192–5.[CrossRef][Medline]

[11] Byrd CL, Schwartz SJ, Hedin N. Lead extraction. Indications and techniques. Pacing Clin Electrophysiol 1992; 10: 735–48.

[12] Myers MR, Parsonnet V, Bernstein AD. Extraction of implanted transvenous pacing leads: a review of a persistent clinical problem. Am Heart J 1991; 121: 881–8.[CrossRef][Web of Science][Medline]

[13] Balau J, Buysch KH, Marx E, Seling A, Knieriem H. Thrombosis of the vena subclavia following transvenous pacemaker implantation. Radiologe 1971; 11: 50–3.[Medline]

[14] Marx E, Schulte HD, Balau J, Buyusch KH. Phlebographic and clinical early and late findings in transvenously implanted pacemaker electrodes. Z Kreislaufforsch 1972; 61: 115–23.[Web of Science][Medline]

[15] Mitrovic V, Thormann J, Schlepper M, Neuss H. Thrombotic complications with pacemakers. Int J Cardiol 1983; 2: 363–74.[CrossRef][Web of Science][Medline]

[16] Zuber M, Huber P, Fricker U, Buser P, Jager K. Assessment of the subclavian vein in patients with transvenous pacemaker leads. Pacing Clin Electrophysiol 1998; 21: 2621–30.[CrossRef][Medline]

[17] de Cock CC, Vinkers M, Van Campe LC, Verhorst PM, Visser CA. Long-term outcome of patients with multiple (≥3) noninfected transvenous leads: a clinical and echocardiographic study. Pacing Clin Electrophysiol 2000; 23: 423–6.[CrossRef][Medline]

[18] Pauletti M, Di Ricco G, Solfanelli S, Marini C, Contini C, Giuntini C. Venous obstruction in permanent pacemaker patients: an isotopic study. Pacing Clin Electrophysiol 1981; 4: 36–42.[CrossRef][Medline]

[19] Seeger W and Scherer K. Asymptomatic pulmonary embolism following pacemaker implantation. Pacing Clin Electrophysiol 1986; 9: 196–9.[CrossRef][Medline]

[20] Oginosawa Y, Abe H, Nakashima Y. Prevalence of venous anatomic variants and occlusion among patients undergoing implantation of transvenous leads. Pacing Clin Electrophysiol 2005; 28: 425–8.[CrossRef][Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
Y. Y. Copperman
Optimal strategy in lead failure
Europace, February 5, 2010; (2010) euq005v1.
[Full Text] [PDF]


Home page
EuropaceHome page
G. Z. Duray, C. W. Israel, D. Pajitnev, and S. H. Hohnloser
Upgrading to biventricular pacing/defibrillation systems in right ventricular paced congestive heart failure patients: prospective assessment of procedural parameters and response rate
Europace, January 1, 2008; 10(1): 48 - 52.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
9/5/328    most recent
eum019v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (7)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Haghjoo, M.
Right arrow Articles by Sadr-Ameli, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haghjoo, M.
Right arrow Articles by Sadr-Ameli, M. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?