Europace Advance Access originally published online on February 7, 2006
Europace 2006 8(3):168-174; doi:10.1093/europace/euj052
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
ICDS
Health-related quality of life of patients with implantable cardioverter defibrillators compared with that of pacemaker recipients

1 Department of MedicineLandspitali University HospitalHringbraut, 101 Reykjavik Iceland ; 2 Department of PsychiatryLandspitali University HospitalHringbraut, 101 Reykjavik Iceland ; 3 Department of Cardiothoracic SurgeryLandspitali University HospitalHringbraut, 101 Reykjavik Iceland ; 4 Department of AnthropologyUniversity of IcelandSudurgata, 101 Reykjavik Iceland
Manuscript submitted 21 February 2005. Accepted after revision 21 November 2005.
* Corresponding author. Tel: +354 543 1000; fax: +354 543 6467. E-mail address: davidar{at}landspitali.is
| Abstract |
|---|
|
|
|---|
Aims Studies indicate a poorer quality of life (QoL) for implantable cardioverter defibrillator (ICD) patients than for the general population. However, studies comparing the QoL of ICD patients with that of patients with other implantable cardiac devices are scarce. We hypothesized that ICD patients had a poorer QoL than pacemaker patients.
Methods and results All ICD patients living in Iceland at the beginning of 2002 (44 subjects), and a comparison group of 81 randomly selected patients with pacemakers were invited to participate. The Icelandic Quality of Life Questionnaire (IQL), the General Health Questionnaire (GHQ), the Beck Anxiety Inventory (BAI), and the Beck Depression Inventory (BDI) were submitted to measure QoL, psychiatric distress, and symptoms of anxiety and depression. The ICD and pacemaker groups did not differ on IQL, BAI, BDI, or GHQ scores. ICD patients were as a group more fearful of death (P=0.056) and showed more concerns about returning to work (P=0.072), although these items fell just short of statistical significance.
Conclusion Contrary to our expectations, ICD patients had a comparable QoL with pacemaker recipients and were not more likely to suffer from anxiety, depression, or general psychiatric distress. These findings are encouraging in view of expanding ICD indications.
Key Words: Anxiety, Depression, Implantable cardioverter defibrillators, Pacemakers, Quality of life
| Introduction |
|---|
|
|
|---|
Indications for the use of implantable cardioverter defibrillators (ICDs) have been expanding in recent years following the publications of several large multi-centre trials and now include preventive implantation for patients with coronary artery disease and a severely depressed ejection fraction.1
Studies on the QoL of patients with pacemakers, who served as a control group in our study, indicate a similar QoL for this patient group to that of patients with other chronic medical illnesses.11
,12
Both ICD patients and pacemaker patients have an implanted cardiac device, but pacemaker patients are less likely to be aware of its function than ICD patients are of their defibrillator.
In this study, we examined the QoL of ICD patients compared with that of pacemaker patients. We hypothesized, given the potential of unexpected uncomfortable shocks, that the ICD group would score higher on subjective measures of anxiety, depression, and general psychiatric distress and report a poorer QoL than pacemaker recipients.
| Methods |
|---|
|
|
|---|
Design
This was a cross-sectional study where all living ICD patients in Iceland were compared with a group of pacemaker recipients attending the same outpatient clinic, at the University Hospital in Reykjavik. The study complied with the Declaration of Helsinki.
Subjects
Following review and approval by the Institutional Review Committee of Landspitali University Hospital and the Icelandic Data Protection Commission, a letter of invitation was sent to all ICD recipients in Iceland who were alive in January 2002. A similar letter was sent to a randomly selected comparison group of patients with pacemakers. The letter included information about the aims and possible benefits of the study, inclusion criteria for research and control subjects, and contact information if further details were required. To increase the power of the study and minimize the risk of age confounding the comparison, we divided both pacemaker and ICD patients into 10 year age bands and randomly selected approximately twice as many pacemaker patients as ICD recipients from each age band, hence broadly but not individually matching by age. Exclusion criteria included having major mental or physical disabilities and to be accordingly considered unable to answer the questionnaires by their caring physicians.
The subjects were offered participation during their next visit to the outpatient clinic at the University Hospital, but all ICD and the majority of pacemaker patients in Iceland are seen at this clinic. The ICD sample is therefore population based and the same applies to a similar degree to the comparison group.
Measures
We used four different questionnaires to assess anxiety, depression, psychiatric distress, and health-related QoL. An additional questionnaire was administered to address concerns, which might be of special relevance to ICD patients.
The Beck Anxiety Inventory (BAI) and The Beck Depression Inventory (BDI) were formulated by Beck et al.13
,14
Each questionnaire consists of 21 questions, which measure self-reported anxiety and depression.
The General Health Questionnaire (GHQ) is a screening tool to measure psychiatric distress (an indicator of psychiatric symptoms) related to general medical illness.15
,16
The questionnaire is available in four versions, differing in length. We used the 30-item version, which is the version recommended by the authors for screening purposes.
The Icelandic Quality of Life Questionnaire (IQL) was used to assess subjects' perception of their health-related QoL.17
,18
This is a recently developed generic 32-item questionnaire which measures 12 aspects of health-related QoL: general health, cognition, depression, social functioning, financial status, energy, anxiety, physical health, self-control, sleep, general well-being, and pain. It has in recent years been validated and used in a number of Icelandic studies.17
,19
To address additional concerns of particular relevance to ICD patients, we used the ICD Psychosocial Indexa 14-item questionnaire formulated by McHugh-Schuster et al.20
These authors used it in their study on QoL issues in ICD patients but have to our knowledge not validated it further. The inventory was translated into Icelandic and adjusted to our local clinical setting.
After signing an informed consent form, participants were asked to fill out these five questionnaires before they left the clinic.
Sampling and response rates
A letter of invitation with information about the study was sent to 44 ICD patients and 81 pacemaker patients in the beginning of 2002. ICD patients attend the outpatient clinic on average every 3 months and pacemaker patients on average every 6 months. We continued to enrol patients into the study for 17 months. One patient was excluded from the ICD group and three from the pacemaker group as they met the exclusion criteria. Two ICD patients and five pacemaker patients did not attend the clinic during the enrolment period, despite the invitation. Two pacemaker patients died during the study period.
All 41 ICD patients that attended the outpatient clinic during the study period accepted the invitation to participate in the study (41/44=93%). Of 71 pacemaker patients who attended the clinic during the study period, 67 agreed to participate, but 6 patients who were allowed to complete the questionnaires at home failed to return them and therefore 61 responses were received (61/81=75%).
Power
Power analysis indicated that the study should have >80% power to identify clinically relevant differences of 35 and 10% of either moderate or severe anxiety scores on the BAI among ICD patients and the comparison group of twice as many pacemaker recipients, respectively, at a 5% level of statistical significance. This is based on the assumption that 8590% of the invited ICD and pacemaker patients accepted the offer of participation in the study.
Statistical analysis
All the questionnaires except the ICD Psychosocial Index rely on a summary of individual question scores rather than a mean score. In the event of missed answers on the IQL questionnaire, we corrected for such missed answers with mean scores for the relevant question from the patient's group as a whole (ICD or pacemaker patients). In line with authors' guidelines, missed answers on the GHQ, BAI, and BDI were given a score of 0. Questionnaires were excluded from the analysis if a patient failed to answer two or more questions on the relevant questionnaire.
The
2 test and Student's t-test were performed to evaluate differences in demographic data between the two groups. Mean values for BAI, BDI, and GHQ scores were compared between the groups using Student's t-test. Mean values for each aspect of the IQL and each question in the ICD Psychosocial Index were compared in the same manner. A conventional level of statistical significance was used (
=0.05) and all comparisons were two tailed. Because of the modest sample size, which limits the study's power to identify small or moderate effects, we did not correct for multiple testing. Results are presented as mean±standard deviation (SD).
| Results |
|---|
|
|
|---|
Sample characteristics
Demographic comparisons are presented in Table 1. As shown in the table, the two groups were comparable and did not differ significantly with regard to age, sex, marital status, or occupational status. Time from implantation to the end of the study period was shorter among the ICD patients or 37.8±28.6 months (range 11.6154.9 months) compared with 76.6±60.9 months for pacemaker patients (range 13.4290.6 months) (P<0.001).
|
Outcome measures
As shown in Figure 1, the two groups did not differ significantly with regard to self-reported anxiety on the BAI (ICD patients: 8.0±7.8; pacemaker patients: 7.7±6.9; P=0.819), self-reported depression on the BDI (ICD patients: 8.7±6.3; pacemaker patients: 6.6±6.7; P=0.121), or overall psychiatric distress on the GHQ (ICD patients: 5.3±5.9; pacemaker patients: 4.1±5.3; P=0.320). The 12 aspects of the IQL questionnaire did not show any significant difference between the two groups (Figure 2).
|
|
Some of the questions on the ICD Psychosocial Index revealed a marked numerical difference between ICD and pacemaker patients, although this fell just short of statistical significance (Figure 3). ICD patients expressed, for instance, more fear of device malfunction (P=0.084), more fear of death (P=0.055), greater concerns about not being able to work (P=0.061), more worried about having sex (P=0.072), and more worried about driving a car (P=0.080). Nineteen of the 41 ICD patients (46.3%) had received shocks (median number of shocks 3, range 143). No statistical differences were found between ICD patients who had received shocks and those who had not on any of the inventories.
|
With the exception of more fear of death, fear of device malfunction, and fear of shocks on the ICD Psychosocial index, younger ICD patients (<60 years of age, n=16) had better scores on the inventories than older ICD patients (n=25). The difference was only statistically significant on the GHQ (P=0.002).
Reference values
For the BAI, BDI, GHQ, and IQL, we plotted scores for the two patient groups against reference values used for these inventories. As shown in Figure 4, the total score for the 21 questions on the BAI ranges from 0 to 63. User guidelines refer to scores of 09 as minimal anxiety, 1016 as mild, 1729 as moderate, and 3063 as severe anxiety.16
Six of 40 ICD patients who completed the inventory scored 17 or above (15.0%) and would thus be classified as having moderate or severe anxiety. Seven of the 55 pacemaker patients completing the questionnaire scored 17 points or more (12.7%), ranking accordingly as moderately or severely anxious. Also for the BDI, scores range from 0 to 63 and are interpreted in the same manner as for the BAI (09 minimal depression, 1016 mild, 1729 moderate, 3063 severe depression).16
Four of 41 ICD patients scored 17 or above (9.8%) on the BDI, as did 2 of the 54 pacemaker patients (3.7%) who completed the questionnaire (Figure 4). For the 30-item GHQ, scores range from 0 to 30 using the GHQ scoring system.16
Patients scoring 5 points or more are considered probable psychiatric cases. Of 40 ICD patients completing the questionnaire, 14 scored 5 points or more (35.0%) and 19 of 57 pacemaker patients would also be classified as probable psychiatric cases (33.3%) using the same cut-off (Figure 5). Concerning the IQL Questionnaire, scores for the two patient groups are compared graphically with reference values for healthy subjects 5069-year-old, retrieved from the authors of the questionnaire (Figure 2).
|
|
| Discussion |
|---|
|
|
|---|
Contrary to our initial hypothesis, no significant differences were observed between ICD recipients and pacemaker patients in our nationwide population-based sample on anxiety, depression, or QoL. Although the ICD Psychosocial Index did indicate some differences between the two groups, ICD patients expressed more concerns about death and more fear of device malfunction and greater concerns about working, having sex, and driving a car, but these differences fell just short of statistical significance. These differences were, however, all in the same direction and possibly of some clinical relevance.
The main strength of this study is the fact that it was population based and very high recruitment was attained for the ICD group, 93% of all living ICD recipients in Iceland taking part. Furthermore, several instruments were used to measure anxiety, depressive symptoms, general psychiatric distress, QoL, and concerns of particular relevance to patients with implanted cardiac devices.
Limitations
The present study had several limitations. First, and perhaps most significantly, the size of the study was modest. This limits the power to identify small- and medium-sized effects. Second, the response rate was somewhat lower in the pacemaker group (75 vs. 93%) and questions not answered were also more frequent in that group. This might partly be explained by the fact that the study was designed to evaluate anxiety, depression, and QoL among ICD patients, and as a result, the pacemaker group might not have been enthusiastic about participation. Third, we did not record underlying cardiac illnesses and co-morbidity for the patients, so any such differences between the two groups are unrevealed. For the same reason, the extent to which the underlying cardiac illness rather than the device itself affects QoL of the patients remains unknown. Other differences between the two study groups, such as circumstances leading to device implantation, age at implantation, time from implantation to conduction of the study, and the mere size of device implanted, may also be confounding factors. Fourth, the relatively low incidence of shocks received in the ICD group might partly explain the lack of difference between the two groups, but previous studies have indicated that it may affect the psychological well-being of ICD recipients.21
24
Fifth, the fact that all of the measurements used in this study, apart from the ICD Psychosocial Index, are well known and widely used generic measures and not disease specific, could have affected the observed outcome. The use of such generic measures will, though, facilitate comparisons with other patient groups.
Anxiety
Most studies examining psychological disorders among ICD patients agree on anxiety being the one most commonly encountered in this patient group, with diagnostic rates for clinically significant anxiety ranging from 13 to 38%.5
,25
To our knowledge, only one study has previously been published, which compares QoL and signs of affective disorders between pacemaker and ICD patients. Duru et al.26
evaluated QoL and signs of anxiety and depression in 76 patients with ICDs, compared with 76 patients with pacemakers in a recent paper. Probable anxiety disorder was encountered in 13.1, 9.7, and 13.3% of the pacemaker, non-shocked, and shocked ICD patient groups, respectively.26
This is similar to the findings in our study, where 15.0% of the ICD patients and 12.7% of the pacemaker patients would be classified as having moderate or severe anxiety by means of their BAI scores. These relatively low percentages, compared with previous studies, might be partly explained by the fact that ICD technology has improved considerably over the last 10 years, with more arrhythmias being terminated by anti-tachycardia pacing techniques, resulting in fewer shocks actually being felt by the patients.27
Depression
A recent study by Ruo et al.,28
on QoL among patients with coronary artery disease, showed that depression is a stronger indicator of poor QoL among this patient population than physiological measures of cardiac function, such as ejection fraction. In their study, 20% of the patient population had symptoms of major depression. In another study on depressive symptoms among patients with coronary artery disease,
12% showed signs of moderate or severe depression by means of the BDI, at 18 months after myocardial infarction.29
In our study, 9.8% of the ICD patients and 3.7% of the pacemaker patients met cut-off levels for moderate or severe depression by means of the BDI. Probable depressive disorder observed in the study of Duru et al.26
were even lower, with 5.2% of the pacemaker patients and 6.5% ICD patients suffering from depression.
Quality of life
Originally, studies on QoL among ICD patients were mostly observational studies of limited size with no comparative groups.6
More recently, QoL data have been emerging from the large randomized preventive ICD implantation and ICD vs. anti-arrhythmic drug trials, where QoL has been evaluated in subsamples of the patient populations and compared with medically treated patients.7
Duru et al. evaluated QoL in their paper, with the ICD patients further divided into two groups, depending on whether they had received shocks. As in our study, no significant differences were observed on measurements of QoL between the two groups.
It may be the case that in spite of the ICD's ability to produce uncomfortable and unpredictable shocks, ICD patients are relatively positive towards their devices, because of their life-saving quality.6
This might affect ICD patients' overall perspective and subjective QoL and nurture optimism, despite the seriousness of the underlying disease.
Even though QoL as a whole was not significantly different between our patient groups, various aspects of daily life, affecting ICD patients' ability to adapt socially, seem to be of concern to this patient group. The ICD patients expressed somewhat more concerns about activities such as driving a car and having sex, about device malfunction, and about dying, with differences between the groups falling just short of statistical significance but being in the same direction for all items. This may not be surprising, because the ICD is literally a life-saving device and thus the possible consequences of device malfunction would be expected to be more distressing than for pacemaker patients. The unpredictability and discomfort of shocks are also probably an important contributing factor when considering concerns about driving a car and having sex. Studies have also shown that the recommended abstinence from driving after ICD implantation is very distressing for many ICD patients, as it hampers their ability to return to previous routines in their life.30
The observed difference between our two study groups and the normal population reference values on energy and general health aspects of the IQL questionnaire (Figure 2) is probably explained by the fact that the reference values are based on largely healthy individuals as opposed to individuals often with severe medical illnesses in our study groups. Conclusions about this difference must be drawn with some caution, because the populations also differ in other aspects, including age and sex to some degree.
ICD patients receiving shocks vs. those not having received a shock
When reviewing the literature, the majority of studies comparing QoL for shocked vs. non-shocked ICD patients reports a worse outcome for shocked ICD patients.21
24
The AVID Trial (Antiarrythmics Versus Implantable Defibrillators Trial), CIDS (Canadian Implantable Defibrillator Study), and CABG Patch Trial research groups all reported either a stable or declining QoL for shocked ICD-patients over a 12 month follow-up period after ICD implantation, compared with that for non-shocked patients, with sample sizes ranging from 317 to 905 patients.21
23
In our sample of 41 ICD patients, however, no statistical differences were observed on any of the questionnaires administered between shocked and non-shocked ICD patients. The risk of type II error has to be kept in mind when making such subgroup comparisons.
General psychiatric distress
Approximately 35% of both our patient groups showed signs of general psychiatric distress by means of the GHQ. This is compatible with psychiatric symptoms detected among patients seeking primary care.31
,32
Previous studies have shown that administering relatively simple measurement tools such as the GHQ can help to detect psychological symptoms that may otherwise not reach diagnostic thresholds, but which are associated with an increased risk of later developing psychiatric illness and disability.32
,33
Future implications
Earlier studies and our own study indicate that both ICD patient and pacemaker patient populations include individuals at high risk of developing common mental disorders. To which extent the device itself, on one hand, and the underlying cardiac illnesses, on the other hand, play a role remains unanswered. Either way, it is necessary for health-care personnel to be aware of signs and symptoms of anxiety and depression when attending to these patients. Preventive measures are also very important, with adequate patient education and awareness, support groups for patients, and family members having shown beneficial results for their psychological well-being.34
,35
We are therefore pleased to report that in the wake of this study, an ICD patient support network was set up among ICD patients in Iceland.
The fact that the ICD patients in our study expressed somewhat more concerns about specific activities such as driving a car and having sex, about device malfunction, and about dying raises the question whether this patient group might need a more standardized approach to prepare them for life with a defibrillator. A randomized controlled trial on whether specified patient education prior to implantation of an ICD might help to reduce these concerns is a highly relevant topic for further research.
| Conclusions |
|---|
|
|
|---|
Our study indicates that health-related QoL appears to be similar among ICD patients and pacemaker recipients. This is of importance in the light of the expanding use of ICDs in patients with coronary artery disease and a decreased ejection fraction. Nevertheless, individuals are found among both ICD and pacemaker patients who seem to suffer substantially from anxiety or depression. This study therefore supports the suggestions set out by others28
| Acknowledgements |
|---|
|
|
|---|
The authors would especially like to thank Kristinn Tómasson, Tómas Helgason, and Júlíus K. Björnsson for their help with the Icelandic Quality of Life Questionnaire, Örn Ólafsson for his help with statistical analysis, and Jón Friðrik Sigurðsson for assistance with administration of the BAI. Additional thanks to the staff at the pacemaker and ICD clinic at Landspitali University Hospital, for all their help. Last but not least, the authors thank all the individuals who participated in the study. This study was supported by grants from Landspitali University Hospital Science Fund, Reykjavik, Iceland and the Sigurlidi Kristjansson and Helga Jonsdottir Memorial Foundation.
| Footnotes |
|---|
Present address. Department of Cardiology, Malmö University Hospital (UMAS), S-205 02 Malmö, Sweden. | References |
|---|
|
|
|---|
[1] ;. ACC/AHA Task Force. ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article. Circulation 2002; 106: 214561.
[2] Moss AJ, Zareba W, Jackson Hall W, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction (MADIT II). N Engl J Med 2002; 346: 87783.
[3] Heidenreich PA, Keeffe B, McDonald KM, Hlatky MA. Overview of randomized trials of antiarrythmic drugs and devices for the prevention of sudden cardiac death. Am Heart J 2002; 144: 42230.[CrossRef][Web of Science][Medline]
[4] Seidl K and Senges J. Worldwide utilization of implantable cardioverter/defibrillators now and in the future. Card Electrophysiol Rev 2003; 7: 513.[Medline]
[5] Sears SF, Todaro JF, Lewis TS, Sotile W, Conti J. Examining the psychosocial impact of implantable cardioverter defibrillators: a literature review. Clin Cardiol 1999; 22: 4819.[Web of Science][Medline]
[6] Gallagher RD, McKinley S, Mangan B, Pelletier D, Squire J, Mitten-Lewis S. The impact of the implantable cardioverter defibrillator on quality of life. Am J Crit Care 1997; 6: 1624.[Abstract]
[7] McCready MJ and Exner DV. Quality of life and psychological impact of implantable cardioverter defibrillators: focus on randomized controlled trial data. Card Electrophysiol Rev 2003; 7: 6370.[CrossRef][Medline]
[8] Bourke JP, Turkington D, Thomas G, McComb J, Tynan M. Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators. Heart 1997; 78: 5813.
[9] Dunbar SB, Warner CD, Purcell JA. Internal cardioverter defibrillator device discharge: experiences of patients and family members. Heart Lung 1993; 22: 494501.[Web of Science][Medline]
[10] Eckert M and Jones T. How does an implantable cardioverter defibrillator (ICD) affect the lives of patients and their families? Int J Nurs Pract 2002; 8: 1527.[Medline]
[11] Aydemir P, Ozmen E, Kuey L, Kultur S, Yeril M, Postaci N, et al. Psychiatric morbidity and depressive symptomatology in patients with permanent pacemakers. Pacing Clin Electrophysiol 1997; 20: 162832.[CrossRef][Medline]
[12] Lamas GA, Orav J, Stambler BS, et al. Quality of life and clinical outcomes in elderly patients treated with ventricular pacing as compared with dual-chamber pacing. N Engl J Med 1998; 338: 1097104.
[13] Beck AT, Epstein N, Brown G, Steer RA. An inventory for measuring clinical anxiety: psychometric properties. J Consult Clin Psychol 1988; 56: 8937.[CrossRef][Web of Science][Medline]
[14] Beck AT, Ward CH, Mendelson M, Mock J, Erbaugh J. An inventory for measuring depression. Arch Gen Psychiatry 1961; 4: 56171.
[15] Goldberg DP. The Detection of Psychiatric Illness by Questionnaire. 1972; London, UK Oxford University Press.
[16] . Task Force for the Handbook of Psychiatric Measures. Handbook of Psychiatric Measures 2000; Washington, USA American Psychiatric Association.
[17] Björnsson JK, Tómasson K, Ingimarsson S, Helgason T. Health-related quality of life of psychiatric and other patients in Iceland: psychometric properties of the IQL. Nord J Psychiatry 1997; 51: 18391.
[18] Helgason T, Björnsson JK, Tómasson K, Grétarsdóttir E. Health-related quality of life among Icelanders [Icelandic]. Icelandic Med J 2000; 86: 2517.
[19] Gudmundsson OO and Tomasson K. Quality of life and mental health of parents of children with mental health problems. Nord J Psychiatry 2002; 56: 4137.[Medline]
[20] McHugh Schuster P, Phillips S, Dillon D, Tomich P. The psychosocial and physiological experiences of patients with an implantable cardioverter defibrillator. Rehabil Nurs 1998; 23: 307.[Medline]
[21] Schron EB, Exner DV, Yao Q, et al. The AVID Investigators. Quality of life in the antiarrythmics versus implantable defibrillators trial. Impact of therapy and influence of adverse symptoms and defibrillator shocks. Circulation 2002; 105: 58994.
[22] Irvine J, Dorian P, Baker B, et al. for the CIDS Investigators. Quality of life in the Canadian Implantable Defibrillator Study (CIDS). Am Heart J 2002; 144: 2829.[Web of Science][Medline]
[23] Namerow PB, Firth BR, Heywood GM, Windle JR, Parides MK. Quality-of-life six months after CABG surgery in patients randomized to ICD versus no ICD therapy: findings from the CABG Patch Trial. Pacing Clin Electrophysiol 1999; 22: 130513.[CrossRef][Medline]
[24] Dougherty CM. Psychological reactions and family adjustment in shock versus no shock groups after implantation of internal cardioverter defibrillator. Heart Lung 1995; 23: 28191.
[25] Hegel MR, Griegel LE, Black C, Goulden L, Ozahowski T. Anxiety and depression in patients receiving implantable cardioverter defibrillators: a longitudinal investigation. Int J Psychiatry Med 1997; 27: 5769.[Web of Science][Medline]
[26] Duru F, Klaghofer R, Mattmann H, Sensky T, Buddeberg C, Candinas R. How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life? Heart 2001; 85: 3759.
[27] Grosse-Meininghaus D, Siebels J, Wolpert Ch, et al. Efficacy of antitachycardia pacing confirmed by stored electrograms. A retrospective analysis of 613 stored electrograms in implantable defibrillators. Z Kardiol 2002; 91: 396403.[Medline]
[28] Ruo B, Rumsfeld JS, Hlatky MA, Liu H, Browner W, Whooley M. Depressive symptoms and health-related quality of life. The heart and soul study. JAMA 2003; 290: 21521.
[29] Luutonen S, Holm H, Salminen JK, Risla A, Salokangas RKR. Inadequate treatment of depression after myocardial infarction. Acta Psychiatr Scand 2002; 106: 4349.[CrossRef][Medline]
[30] Werner J and Lüderitz B. Quality of life and driving in recipients of the implantable cardioverter-defibrillator. Am J Card 1996; 78: 516.
[31] Plummer SE, Gournay K, Goldberg D, Ritter SA, Mann AH, Blizard R. Detection of psychological distress by practice nurses in general practice. Psychol Med 2000; 30: 12337.[CrossRef][Medline]
[32] Ormel J, Van Den Brink W, Koeter MW. Recognition management:outcome of psychological disorders in primary care: a naturalistic follow-up study. Psychol Med 1990; 20: 90923.[Web of Science][Medline]
[33] Gureje O. Psychological disorders and symptoms in primary care. Association with disability and service use after 12 months. Soc Psychiatry Psychiatr Epidemiol 2002; 37: 2204.[CrossRef][Medline]
[34] Badger MJ and Morris PLP. Observations of a support group for automatic implantable cardioverter-defibrillator recipients and their spouses. Heart Lung 1989; 18: 23843.[Medline]
[35] Edelman S, Lemon J, Kidman A. Psychological therapies for recipients of implantable cardioverter defibrillators. Heart Lung 2003; 32: 23440.[CrossRef][Medline]
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
A. S. Kelley, S. S. Mehta, and M. Carrington Reid Management of Patients with ICDs at the End of Life (EOL): A Qualitative Study American Journal of Hospice and Palliative Medicine, January 1, 2009; 25(6): 440 - 446. [Abstract] [PDF] |
||||
![]() |
D. H. Birnie, S. F. Sears, M. S. Green, R. Lemery, M. H. Gollob, and B. Amyotte No long-term psychological morbidity living with an implantable cardioverter defibrillator under advisory: the Medtronic Marquis experience Europace, January 1, 2009; 11(1): 26 - 30. [Abstract] [Full Text] [PDF] |
||||
![]() |
E.G. Newall, N.A. Lever, S. Prasad, C. Hornabrook, and P.D. Larsen Psychological implications of ICD implantation in a New Zealand population Europace, January 1, 2007; 9(1): 20 - 24. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||






