Europace 2009 11(4):400-401; doi:10.1093/europace/eup057
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in Europace
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Van Belle, Y.
Right arrow Articles by Jordaens, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Belle, Y.
Right arrow Articles by Jordaens, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2009. For permissions please email: journals.permissions@oxfordjournals.org
The online version of this article has been published under an open access model. Users are entitled to use, reproduce, disseminate, or display the open access version of this article for non-commercial purposes provided that the original authorship is properly and fully attributed; the Journal, Learned Society and Oxford University Press are attributed as the original place of publication with correct citation details given; if an article is subsequently reproduced or disseminated not in its entirety but only in part or as a derivative work this must be clearly indicated. For commercial re-use, please contact journals.permissions©oxfordjournals.org.


EDITORIALS

Reflections on reconduction after pulmonary vein isolation

Yves Van Belle* and Luc Jordaens

Department of Cardiology, Erasmus MC, Rotterdam, The Netherlands

Manuscript submitted 3 February 2009. Accepted after revision 5 February 2009.

* Corresponding author. Tel: +31107033991, Email: y.vanbelle{at}erasmusmc.nl

This editorial refers to ‘Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: a prospective study’ by G. B. Chierchia et al., on page 445

Cryoballoon has proven to be a formidable competitor in the field of novel technologies for the ablation of atrial fibrillation (AF). Several reports have shown this technique to be safe and effective in treating AF, with 59–74% freedom of paroxysmal AF and 42% of persistent AF, for more than 1 year. Its major complication is temporary phrenic palsy caused by the ablation of the right superior phrenic nerve.1Go–3Go In contrast to other balloon technologies, it is the only one whose outcome results are currently extensively reported in scientific literatures and seem promising. Two other balloon-based devices, but employing a different energy source, have not proven to live up to safety standards: high-intensity focused ultrasound (HIFU) balloon and endoscopically guided laser balloon. The former was not only reported to have a high percentage of permanent phrenic nerve paralysis (which seems a problem inherent to any balloon concept),4Go but evidence emerged that the dreaded atrio-oesophageal fistula was one of its major complications.5Go After that, the FDA-approved HIFU ablation system study (randomizing ablation against anti-arrhythmic drugs) was suspended. Similarly, the first generation of the endoscopically guided laser balloon did not survive early phase III testing, and the FDA-approved ENABLE study (comparing ablation against anti-arrhythmic drugs) was terminated. Another investigational device (not a balloon catheter, however) showing promising results seems to be the multipolar ablation catheter with duty-cycled bipolar and unipolar radiofrequency energy, which has recently shown to have 83% freedom of AF at 6 months and no major complications.6Go Two studies are currently underway: the TOPP AF trial (multicentre, randomizing ablation against DC cardioversion for permanent AF) and a single-centre trial for paroxysmal AF randomizing against wide circumferential pulmonary vein (PV) isolation. This shows that the current scientific interest in catheters capable of simplifying AF ablation is major and that knowledge on these new devices is still scarce but urgently needed.

Reporting on the cryoballoon ablation, Chierchia et al.,7Go try to leap beyond merely reporting on AF recurrence, by shedding some light on the time span for early recovery of conduction after PV isolation. On this matter, a large volume of publications exist in radiofrequency ablation, but little is known about cryothermal ablation. It has long been known that in radiofrequency PV ablation, reconduction to the PVs is an important cause of recurrent AF. It is responsible for ~80% of recurrences of AF.8Go,9Go Early reconduction after RF ablation of the PVs occurs usually within 60 min after ablation and, on average, in two veins.10Go Therefore, a large number of operators take into account a 60 min waiting period after PV isolation before rechecking conduction. Moreover, dormant or stunned PV sleeves can be made apparent using adenosine infusion,11Go and ablating these has proven to be successful in preventing recurrent AF. In a population with recurrence of AF after a successful cryoballoon isolation, repeat procedures have shown reconduction in 100% of patients, occurring, on average, in three PVs. Similar to RF ablation, re-ablation yields a high freedom of AF after re-ablation.3Go However, although the mechanism for the recurrence of AF seems to be the same (i.e. reconduction), the difference in ablation energy seems to have an essential effect on the time to recovery of the ablated tissue. As shown in the report by Chierchia et al.,7Go early reconduction during the first 60 min seems to be very rare, since it only happened in ~3% of the ablated veins. The reconducting veins are all right inferior veins, the most difficult to occlude using this balloon device, showing that probably superficial cryomapping is responsible for this phenomenon, linked to the heat-sink effect the passing blood flow has on the endocardial surface. Reconduction after cryoablation occurring later during the clinical course is probably not related to the degree of occlusion, but to anatomical or physiological determinants, such as heating of deeper lying PV tissue by nearby structures with a high blood flow. It has been previously reported that reconduction after cryoballoon ablation is more frequent in the left-sided veins,3Go probably due to the descending aorta directly underlying them and the close proximity of the mitral valve region, warming the deeper PV tissue. If lack of occlusion were responsible for late reconduction, this would have to be more frequent in the lower right-sided vein. Tackling the problem of reconduction seems to be a balance between the power of the ablation and the risk of damaging adjacent structures. In this report, one temporary phrenic nerve palsy was observed, roughly coinciding with the 3% expected incidence reported in larger studies.2Go,3Go The findings of Chierchia et al. pose another problem trying to find how and when recovery of conduction to the PV takes place (if ever) after cryoablation and focus attention on the important challenge of preventing this. It is an essential study in understanding the temporal recovery sequence of the atrial myocardium after cryoablation and aids in determining crucial factors to optimize the cryoballoon ablation strategy.

Conflict of interest: none declared.

Footnotes

The opinions expressed in this article are not necessarily those of the Editors of Europace or of the European Society of Cardiology.

References

[1] Van Belle Y, Janse P, Rivero-Ayerza MJ, Thornton AS, Jessurun ER, Theuns D, et al. Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. Eur Heart J (2007) 28:2231–7.[Abstract/Free Full Text]

[2] Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol (2008) 52:273–8.[Abstract/Free Full Text]

[3] Van Belle Y, Janse P, Theuns D, Szili-Torok T, Jordaens L. One year follow-up after cryoballoon isolation of the pulmonary veins in patients with paroxysmal atrial fibrillation. Europace (2008) 10:1271–6.[Abstract/Free Full Text]

[4] Schmidt B, Antz M, Ernst S, Ouyang F, Falk P, Chun JK, et al. Pulmonary vein isolation by high-intensity focused ultrasound: first-in-man study with a steerable balloon catheter. Heart Rhythm (2007) 4:575–84.[CrossRef][Web of Science][Medline]

[5] Borchert B, Lawrenz T, Hansky B, Stellbrink C. Lethal atrioesophageal fistula after pulmonary vein isolation using high-intensity focused ultrasound (HIFU). Heart Rhythm (2008) 5:145–8.[CrossRef][Web of Science][Medline]

[6] Boersma LV, Wijffels MC, Oral H, Wever EF, Morady F. Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm (2008) 5:1635–42.[CrossRef][Web of Science][Medline]

[7] Chierchia GB, de Asmundis C, Müller-Burri S-A, Sarkozy A, Capulzini L, et al. Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: a prospective study. Europace (2009) 11:445–449.[Abstract/Free Full Text]

[8] Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation (2003) 108:1599–1604.[Abstract/Free Full Text]

[9] Lemola K, Hall B, Cheung P, Good E, Han J, Tamirisa K, et al. Mechanisms of recurrent atrial fibrillation after pulmonary vein isolation by segmental ostial ablation. Heart Rhythm (2004) 1:197–202.[CrossRef][Web of Science][Medline]

[10] Cheema A, Dong J, Dalal D, Marine JE, Henrikson CA, Spragg D, et al. Incidence and time course of early recovery of pulmonary vein conduction after catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol (2007) 18:387–91.[CrossRef][Web of Science][Medline]

[11] Arentz T, Macle L, Kalusche D, Hocini M, Jais P, Shah D, et al. ‘Dormant’ pulmonary vein conduction revealed by adenosine after ostial radiofrequency catheter ablation. J Cardiovasc Electrophysiol (2004) 15:1041–7.[CrossRef][Web of Science][Medline]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?

Related articles in Europace:

Early recovery of pulmonary vein conduction after cryoballoon ablation for paroxysmal atrial fibrillation: a prospective study
Gian Battista Chierchia, Carlo de Asmundis, Stephan-Andreas Müller-Burri, Andrea Sarkozy, Lucio Capulzini, Gaetano Paparella, Sergio Chierchia, Markus Roos, and Pedro Brugada
Europace 2009 11: 445-449. [Abstract] [Full Text]  




This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in Europace
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Van Belle, Y.
Right arrow Articles by Jordaens, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Belle, Y.
Right arrow Articles by Jordaens, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?