Skip Navigation


Europace Advance Access originally published online on March 31, 2008
Europace 2008 10(5):545-551; doi:10.1093/europace/eun073
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/5/545    most recent
eun073v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Johansen, J. B.
Right arrow Articles by Mortensen, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johansen, J. B.
Right arrow Articles by Mortensen, P. T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org


ICDs

Symptomatic heart failure is the most important clinical correlate of impaired quality of life, anxiety, and depression in implantable cardioverter-defibrillator patients: a single-centre, cross-sectional study in 610 patients

Jens B. Johansen1,*, Susanne S. Pedersen2, Helle Spindler3, Kirsten Andersen1, Jens C. Nielsen1 and Peter T. Mortensen1

1 Department of Cardiology, Aarhus University Hospital (Skejby), Brendstrupgaardsvej 100, DK 8200 Aarhus N, Denmark; 2 CoRPS—Center of Research on Psychology in Somatic diseases, Department of Medical Psychology, Faculty of Social and Behavioural Sciences, Tilburg University, PO Box 90153, 5000 LE Tilburg, The Netherlands; 3 Department of Psychology, Aarhus University, Jens Chr. Skous Vej 4, DK 8000 Århus C, Denmark

Manuscript submitted 9 January 2008. Accepted after revision 4 March 2008.

* Corresponding author. Tel: +45 89496136; fax: +45 89496002.E-mail address: brock{at}dadlnet.dk


    Abstract
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
Aims: To identify correlates of impaired quality of life (QOL), anxiety, and depression in patients with an implantable cardioverter-defibrillator (ICD).

Methods and results: Surviving patients (n = 610) who received an ICD in our institution since 1989 completed the Short Form Health Survey (SF-36) and the Hospital Anxiety and Depression Scale. Mean age was 62.4 years with 18% females. In a multivariate logistic regression analysis, symptomatic heart failure was the most important correlate of impaired QOL (SF-36) across all eight subscales [odds ratios (ORs) ranging from 5.21 to 22.53)], whereas psychotropic medication, age, comorbidity, amiodarone, and ICD shocks all correlated to a lesser extent. Symptomatic heart failure was also the most dominant correlate of anxiety [OR 5.15 (3.08–8.63), P < 0.001] and depression [OR 6.82 (3.77–12.39), P < 0.001]. Implantable cardioverter-defibrillator shocks correlated less yet significantly with anxiety [OR 2.21 (1.32–3.72) P < 0.01] and depression [OR 2.00 (1.06–3.80), P < 0.05].

Conclusion: Symptomatic heart failure was the single most important clinical correlate of impaired QOL, anxiety, and depression, with ICD shocks playing only a secondary role. This suggests that comorbidity rather than ICD therapy per se influences patients' device acceptance, supporting the increasing use of prophylactic ICD implantation.

Key Words: Implantable cardioverter-defibrillator, ICD, Quality of life, Anxiety, Depression, ICD shocks


    Introduction
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
Treatment with an implantable cardioverter-defibrillator (ICD) has been shown to reduce mortality significantly in patients at risk of sudden arrhythmic death1Go and in combination with cardiac resynchronization therapy (CRT) also to relieve chronic heart failure (CHF) symptoms, leading to improved quality of life (QOL), exercise capacity, and cardiac function.2Go However, the well-being of an ICD patient can be negatively influenced by a number of factors apart from the risk of dying suddenly or having painful shocks, including the underlying heart disease (e.g. ischaemic vs. non-ischaemic), comorbidity (e.g. CHF), presence of the ICD (e.g. cosmetic), social or professional restrictions (e.g. driver's license), a negative effect on partner and family life or non-optimal information and support from the healthcare system.

Although there has been a strong focus on optimizing the clinical aspects of ICD therapy, only more recently attention has been paid to the psychological issues. Importantly, a subset of patients is prone to experience high levels of ICD concerns, with a negative impact on acceptance of the ICD.3Go Thus, when advocating the widespread use of ICDs, particularly in asymptomatic patients, the psychological impact of living with an ICD should also be considered, because the full benefits of ICD therapy can only be achieved if the patient's QOL and emotional well-being are preserved.

To date, no studies have evaluated QOL, anxiety, and depression and their correlates in a large cross-sectional population of patients with an ICD. Hence, we approached all surviving patients having received an ICD in our institution, with a view to examine the potential influence of a multitude of factors on the QOL and psychological health of the ICD patient.


    Methods
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
Patients
The study population consists of all patients implanted with an ICD at the Aarhus University Hospital (Skejby) since 1989 and still alive on 1 November 2006. Patients with a first ICD implant within the last 3 months were not included. In 95% of the patients, the main indication for ICD was secondary prevention, as primary prevention was not generally implemented in Denmark before 2007. A flow chart of the patient selection is presented in Figure 1.


Figure 1
View larger version (14K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 Flowchart for the study group.

 
All surviving patients received a questionnaire by mail, which they were asked to complete and return in a self-addressed, stamped envelope. If the questionnaire was not returned within 2 weeks, a reminder was sent including a duplicate of the questionnaire. The patient was asked to complete a number of questions on clinical and demographic data and a set of standardized and validated psychological questionnaires. The study was conducted according to the Helsinki Declaration.

Demographic and clinical variables
Data were retrieved from the patients' medical records and the Danish ICD Registry4Go and from purpose-designed questions in the questionnaire. All re-operations caused by device or lead malfunctioning or infection, as registered by the Danish ICD Registry,4Go were considered as complication to ICD therapy. Comorbidity (e.g. gait, diabetes, muscular dystrophy, stroke, cancer, pulmonary disease, and renal insufficiency) and number of ICD shocks were based on self-report. Symptomatic CHF was determined using the Minnesota living with heart failure (MLHF) questionnaire.5Go The 21-item MLHF is a valid and reliable, disease-specific measure of QOL, with items scored on a 6-point Likert scale from 0 (no) to 5 (very much). The total MLHF score ranges from 0 to 105, with a lower score indicating good QOL. Dichotomization was undertaken in order to enhance the interpretation of the results in clinical practice.6Go An MLHF score above 40 represents New York Heart Association (NYHA) classes III–IV (i.e. symptomatic CHF).7Go As the 75% upper percentile in our data was 41, we used at cut-off value of >40 as a marker of symptomatic CHF.

Anxiety and depression symptoms
The 14-item Hospital Anxiety and Depression Scale (HADS)© (see Appendix) was used to assess the symptoms of anxiety (seven items) and depression (seven items).8Go Items are answered on a 4-point Likert scale ranging from 0 to 3 (score range 0–21). The HADS is a valid and reliable instrument across countries in cardiac and non-cardiac populations,9Go–11Go with a recent review demonstrating that a cut-off ≥8 on both subscales represents probable clinical levels.11Go An advantage of the use of HADS in the context of patients with somatic disease is that it is devoid of somatic items and hence more likely to reflect real depressive symptoms rather than underlying disease.10Go

Quality of life
The Short Form Health Survey (SF-36) was used to assess the QOL.12Go The SF-36 is a generic QOL measure comprising eight subdomains: role physical functioning, role emotional functioning, physical functioning, mental health, vitality, social functioning, bodily pain, and general health. Scale scores are obtained by summing the items together within a domain, dividing this outcome by the range of scores, and then transforming the raw scores to a scale from 0 to 100. A higher score on the SF-36 subdomains represents better functioning, with a high score on the bodily pain scale indicating the absence of pain. The scale has good reliability with Cronbach's alpha ranging from 0.65 to 0.96 for all subscales.13Go

Statistics
Continuous variables were compared with Student's t-test for independent samples and discrete variables with the {chi}2 test. In multivariable logistic regression, we analysed demographic and clinical factors as correlates of impaired QOL, anxiety, and depression. Prior to analyses, we dichotomized all QOL scores using the lower tertile on the SF-36 to indicate impaired QoL. In all analyses, we entered age, gender, years in ICD therapy, complication to ICD therapy, smoking, ICD shocks, comorbidity, amiodarone, other anti-arrhythmic medication, psychotropic medication, living with a spouse, ischaemic vs. non-ischaemic aetiology for ICD, and CHF (as expressed by MLHF > 40), which were selected a priori on the basis of the literature. A P-value less than 0.05 was chosen to indicate statistical significance, and all tests were two-tailed. Odds ratios (ORs) with their corresponding 95% confidence intervals (CIs) are reported for the logistic regression analyses. All analyses were performed using SPSS 13.0 for Microsoft Windows.


    Results
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
Of the 723 potentially eligible patients, 624 returned the questionnaire (response rate 86%) and data were adequate for 610 patients (84%). Patients included in the study were slightly older 62.4 ± 14.2 vs. 58.8 ± 16.2 (P < 0.05, Student's t-test), and those included also had a higher prevalence of ischaemic aetiology for ICD therapy (63 vs. 52%, P < 0.05, {chi}2), compared with those not included. Years of ICD treatment, gender, proportion of cardiac resynchronization therapy device and defibrillator (CRT-D), and complications were evenly distributed (data not shown).

Baseline characteristics
Basic demographic and clinical data for the 610 patients who constituted the study group (Figure 1) are shown in Table 1. The mean age was 62.4 years, which is comparable with other studies, whereas male gender was more dominant (82%) in comparison with 76–80% seen in other major studies.14Go,15Go Only 110 patients (18.0%) were implanted with a CRT-D and 578 patients (95%) had secondary prevention as indication, reflecting the historical data. A total of 51 (8.4%) patients had device-related complications such as infection, premature end of life of the device, lead fracture, and so on, causing re-operation. Major findings were ischemic heart disease in 384 patients (63.0%), comorbidity in 134 patients (22.0%), CHF in 150 patients (24.6%), and treatment with amiodarone in 142 patients (23.3%). As expected, patients with CHF, as measured by an MLHF score >40, were significantly more often treated with CRT-D, CHF medication, and amiodarone (Table 2). The only exception was β-blockers, which was evenly distributed. A total of 263 patients (43.1%) reported having experienced ICD shocks, with 96 patients (15.7%) having received more than three shocks.


View this table:
[in this window]
[in a new window]

 
Table 1 Baseline characteristics for eligible patients with psychological data (n = 610)

 


View this table:
[in this window]
[in a new window]

 
Table 2 Relationship between CHF as indicated by MLHF and other surrogates for CHF

 
Correlates of impaired quality of life
The dominant independent correlate of impaired QOL, as shown in Table 3, was CHF, which was an independent correlate across all eight subscales of the SF-36. Other independent correlates of impaired QOL were psychotropic medication (six of eight subscales), age (four of eight subscales), comorbidity (four of eight subscales), and amiodarone (two of eight subscales). Interestingly, ICD shocks only had a negative effect on one of the eight QOL subscales of the SF-36 (i.e. physical functioning), and no effect was seen on ICD-related complications or years with ICD therapy.


View this table:
[in this window]
[in a new window]

 
Table 3 Correlates of impaired quality of life

 
Correlates of anxiety and depression
Chronic heart failure and, to a lesser degree, ICD shocks were correlates of symptoms of anxiety and depression (Table 4), with women being likely to report anxiety than men and patients using psychotropic medication more likely to report depression. Again, ICD-related complications and years with ICD therapy were not associated with anxiety or depression.


View this table:
[in this window]
[in a new window]

 
Table 4 Correlates of anxiety and depression

 

    Discussion
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
Despite several clinical studies having documented that ICD treatment significantly reduces sudden arrhythmic death, the implantation rate both for primary and secondary prevention shows a worldwide variation.16Go With the addition of CRT to ICD therapy, the benefit of ICD implantation should be even more advantageous for larger patient groups. The extremes are the USA in comparison with the less-developed countries, but even between socio-economically comparable European countries, implantation rates vary considerably.17Go The differences in the rate of ICD implantation can, therefore, only partly be attributed to the availability of economical and medical resources,17Go whereas it has been suggested that local guidelines, psychological and ethical factors may also play a role.18Go

For many physicians, there seems to be an ethical barrier blocking implementation of the international guidelines for ICD implantation. This barrier has been suggested to be due to the physician's concern about the psychological strain on the ICD patient, especially in the case of multiple shocks or device-related complications.18Go However, some of the principal findings of our study are, as also found by others,19Go that shock therapy leads to increased anxiety, although the influence on depression is less clear. More importantly, in the present study, the negative effect induced by shock therapy on QOL was only documented for one of eight subscales of the SF-36. In addition, in contrast to another but considerably smaller study,20Go neither ICD-complications nor years with ICD therapy correlated with impaired QOL or anxiety and depression. The rather low complication rate of 8.4% found in this study21Go,22Go may partly explain the latter finding, thereby also stressing the importance of high medical standards. Taken together, these results show that in our large cohort of ICD patients, in general, ICD therapy was well tolerated also from a psychological point of view.

In the current study, we used the MLHF to evaluate the severity of CHF rather than the NYHA classification system, as the validity and reliability of the latter classification system are the subject of some debate.23Go The MLHF seems to be a good and integrated measure of both physical and mental impairment due to CHF.24Go Furthermore, the simultaneous CHF assessment by MLHF and sampling of SF-36 and HADS data is an advantage of this study, which evaluates the interactions between CHF and QOL and anxiety and depression.

Symptomatic CHF, seen in 25% of the patients, was the strongest correlate of impaired QOL, associated with all SF-36 subscales. This corresponds well with the findings from studies of CHF patients without ICDs.25Go,26Go It also stresses the importance of optimizing CHF medication and adding CRT to ICD therapy in patients with indications for CRT to achieve the additive effect of CRT on top of conventional heart failure drug therapy.27Go

Amiodarone, a class 3 anti-arrhythmic drug primarily used for treatment-resistant tachyarrhythmias, was in the present study independently correlated with impaired QOL on four of eight QOL subscales, likely due to its many and troublesome side effects.28Go Although amiodarone is a proven effective adjunct drug therapy in ICD patients,29Go several long-term studies have also shown that it is poorly tolerated with subsequent low compliance.29Go,30Go This has also been found in other studies in non-ICD patients28Go and thus suggests a restricted use of amiodarone whenever possible.

Clinical levels of anxiety and depression are seen in ~25–30% of ICD patients,31Go which is slightly more than in the current study. Similar to some32Go,33Go but not all studies,34Go we found that CHF and ICD shocks were significant correlates of anxiety and depression. Like others34Go we also found that females were more likely to report anxiety compared with males, and that the use of psychotropic medication was related to depression.

Any physician dealing with ICD therapy is concerned about the constraint forced upon health economics and the complication rate related to device implantation and therapy35Go and the logistics connected to the rapidly increasing number of implants and follow-ups. Everybody can recall single patient cases with multiple shock therapies, being appropriate or inappropriate, leaving the patient and the family in a psychological traumatized state. However, overall findings of the current study indicate that aside from the above-mentioned troublesome but single cases, ICD treatment seems to be well accepted and tolerated by the vast majority of patients. Therefore, whenever sufficient health economics is available, ICD treatment should be offered to all eligible patients also as a primary prevention measure. This recommendation is supported by cost–benefit analyses, demonstrating that ICD treatment is found competitive in comparison with other already fully implemented invasive cardiac strategies.36Go–39Go

Our study is addressing that which is beneficial to the majority of patients and tends to ignore the special needs of individual patients. Pedersen and colleagues have in a number of studies identified a subgroup of ICD patients who are at risk for increased anxiety and depression and poor QOL, with the distressed (Type D) personality and a high score on ICD concerns characterizing these patients.19Go,34Go Besides standard ICD indications based on rigid clinical criteria, this calls for a more patient-specific selection procedure before ICD implantation, with more focus on the individual need of the patient both at the time of evaluation and implantation and in the post-hospitalization follow-up phase. More studies are warranted in this direction in order to be able to identify high-risk patients who may need further support and adjunctive intervention, e.g. of a psychosocial nature. Preliminary evidence from a recent review indicates that such intervention may successfully reduce levels of anxiety.40Go

The results of this study should be interpreted with some caution, as the cross-sectional design of the study does not allow for the inference of cause and effect. In addition, symptomatic CHF was assessed by means of a proxy measure, namely the MLHF questionnaire and we had no information on left ventricular ejection fraction (LVEF), as a measure of disease severity, which could potentially serve as a confounder, although LVEF had no effect on patient-centred outcomes in other studies.3Go,19Go Furthermore, some clinical variables were obtained by means of self-report, which may be subject to bias. In addition, the majority of patients had a secondary indication for ICD implantation, reflecting the historical data. This might imply that the results of the current study may not necessarily be generalizable to ICD patients seen in clinical cardiology practice today, since the number of patients with a primary indication is increasing. Nevertheless, studies examining the influence of indication on patient-centred outcomes, such as QOL, anxiety and depression, have found no support for an effect of indication on these outcomes, including on acceptance of the device.3Go,32Go,41Go,42Go

Despite these limitations, this study also has several strengths, including the relatively high response rate and that this, to our knowledge, is the largest study of ICD patients to report on a broad range of patient-centred outcomes, including QOL, anxiety, and depression.

In conclusion, the present study documents that ICD therapy, in general, is very well accepted by ICD patients, with CHF being the dominant correlate of impaired QOL. Despite ICD implantation reducing cardiac arrhythmic death, this treatment modality is very unevenly distributed among countries, a fact that cannot be fully explained by socio-economical differences. Ethical and psychological factors may play an important role in determining to what extent ICD treatment is implemented in the national health strategies. As a consequence, there seems to be a need for further education and information of the health community, so that ICD treatment is not withheld on subjective reasons, but is offered to all eligible patients including as primary prevention.

In addition, focus should be directed towards improving the QOL and reducing anxiety and depression in a subgroup of patients, particularly those with symptomatic CHF.

Conflict of interest: none declared.


    Funding
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
This research was in part supported with a VENI grant (451-05-001) to Dr. Susanne S. Pedersen from the Netherlands Organisation for Scientific Research, The Hague, The Netherlands.


    Appendix
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
Munksgaard International Publishers Ltd, Copenhagen, 1983. Permission to use HADS can be obtained through nferNelson Publishing Company Ltd, The Chiswick Centre, 414 Chiswick High Road, London W4 5TF, UK. All rights reserved. NferNelson is a division of Granada Learning Ltd, part of Granada plc.


    References
 Top
 Abstract
 Introduction
 Methods
 Results
 Discussion
 Funding
 Appendix
 References
 
[1] Zareba W, Piotrowicz K, McNitt S, Moss AJ. Implantable cardioverter-defibrillator efficacy in patients with heart failure and left ventricular dysfunction (from the MADIT II population). Am J Cardiol (2005) 95:1487–91.[CrossRef][Web of Science][Medline]

[2] Young JB, Abraham WT, Smith AL, Leon AR, Lieberman R, Wilkoff B, et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure. The MIRACLE trial. JAMA (2003) 289:2685–94.[Abstract/Free Full Text]

[3] Pedersen SS, Theuns DAMJ, Muskens-Heemskerk A, Erdman RAM, Jordaens L. Type-D personality but not implantable cardioverter-defibrillator indication is associated with impaired health-related quality of life 3 months post-implantation. Europace (2007) 9:675–80.[Abstract/Free Full Text]

[4] Maisel WH. Pacemaker and ICD generator reliability. Meta-analysis of device registries. JAMA (2006) 295:1929–34.[Abstract/Free Full Text]

[5] Rector TS. A conceptual model of quality of life in relation to heart failure. J Cardiac Failure (2005) 11:173–6.[CrossRef][Web of Science][Medline]

[6] Rumsfeld JS, Magid DJ, Plomondon ME, Sales AE, Grunwald GK, Every NR, et al. History of depression, angina, and quality of life after acute coronary syndromes. Am Heart J (2003) 145:493–9.[CrossRef][Web of Science][Medline]

[7] Rector TS. Overview of the Minnesota living with heart failure® questionnaire, University of Minnesota. www.mlhfq.org/_dnld/mlhfq_overview.pdf (9 January 2008).

[8] Zigmond AS, Snaith RP. The Hospital Anxiety and Depression Scale. Acta Psychiatr Scand (1983) 67:361–70.[Web of Science][Medline]

[9] Spinhoven P, Ormel J, Sloekers PP, Kempen GI, Speckens AE, Van Hemert AM. A validation study of the Hospital Anxiety and Depression Scale (HADS) in different groups of Dutch subjects. Psychol Med (1997) 27:363–70.[CrossRef][Web of Science][Medline]

[10] Herrmann C. International experiences with the Hospital Anxiety and Depression Scale: a review of validation data and clinical results. J Psychosom Res (1997) 42:17–42.[CrossRef][Web of Science][Medline]

[11] Bjelland I, Dahl AA, Haug TT, Neckelman D. The validity of the Hospital Anxiety and Depression Scale: an updated literature review. J Psychosom Res (2002) 52:69–77.[CrossRef][Web of Science][Medline]

[12] Ware JE, Sherbourne CD. The MOS 36-item Short-Form Health Survey (SF-36). Med Care (1993) 30:473–83.[CrossRef][Web of Science]

[13] Smith HJ, Taylor R, Mitchel A. A comparison of four quality of life instruments in cardiac patients: SF-36, QLI, QLMI, and SEIQoL. Heart (2000) 84:390–4.[Abstract/Free Full Text]

[14] Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med (2005) 352:225–37.[Abstract/Free Full Text]

[15] The Antiarrhythmics vs. Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitaded from near-fatal ventricular arrhythmias. N Engl J Med (1997) 337:1576–83.[Abstract/Free Full Text]

[16] Field ME, Sweeney MO. Socio-economic analysis of cardiac resynchronization therapy. J Interv Card Electrophysiol (2006) 17:225–36.[CrossRef][Web of Science][Medline]

[17] Camm AJ, Klein H, Nisam S. The cost of implantable defibrillators: perceptions and reality. Eur Heart J (2007) 28:392–7.[Abstract/Free Full Text]

[18] Heidbüchel H. The cost of implantable defibrillators: how the perception of reality depends on perspective. Eur Heart J (2007) 28:386–7.[Free Full Text]

[19] Pedersen SS, Theuns DAMJ, Erdman RAM, Jordaens L. Clustering of device-related concerns and Type D personality predicts increased distress in ICD patients independent of shocks. Pacing Clin Electrophysiol (2008) 31:20–7.[Medline]

[20] Friedmann E, Thomas SA, Inguito P, Kao CW, Metcalf M, Kelley FJ, et al. Quality of life and psychological status of patients with implantable cardioverter defibrillators. J Interv Card Electrophysiol (2006) 17:65–72.[CrossRef][Web of Science][Medline]

[21] Kleeman T, Becker T, Doenges K, Vater M, Senges J, Schneider S, et al. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Circulation (2007) 115:2474–80.[Abstract/Free Full Text]

[22] Boriani G, Artale P, Biffi M, Martignani C, Frabetti L, Valzania C, et al. Outcome of cardioverter-defibrillator implant in patients with arrhythmogenic right ventricular cardiomyopathy. Heart Vessels (2007) 22:184–92.[CrossRef][Web of Science][Medline]

[23] Raphael C, Briscoe C, Davies J, Whinnett ZI, Manistry C, Sutton R, et al. Limitations of the New York heart association functional classification system and self-reported walking distances in chronic heart failure. Heart (2007) 93:476–82.[Abstract/Free Full Text]

[24] Rector T, Anand I, Cohn J. Relationships between clinical assessments and patients' perceptions of the effects of heart failure on their quality of life. J Card Fail (2006) 12:87–92.[CrossRef][Web of Science][Medline]

[25] Hobbs FDR, Kenkre JE, Roalfe AK, Davis RC, Hare R, Davies MK. Impact of heart failure and left ventricular systolic dysfunction on quality of life. Eur Heart J (2002) 23:1867–76.[Abstract/Free Full Text]

[26] Juenger J, Schellberg D, Kraemer S, Haunstetter A, Zugck C, Haass W. Health related quality of life in patients with congestive heart failure: comparison with other chronic diseases and relation to function. Heart (2002) 87:235–41.[Abstract/Free Full Text]

[27] Cleland JGF, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med (2005) 352:1539–49.[Abstract/Free Full Text]

[28] Vasallo P, Trohman RG. Priscribing amiodarone: an evidence-based review of clinical indications. JAMA (2007) 298:1312–22.[Abstract/Free Full Text]

[29] Ferreira-González I, Dos-Subirá L, Guyatt GH. Adjunctive antiarrhythmic drug therapy in patients with implantable cardioverter defibrillators: a systematic review. Eur Heart J (2007) 28:469–77.[Abstract/Free Full Text]

[30] Bokhari F, Newman D, Greene M, Korley V, Mangat I, Dorian P. Long-term comparison of the implantable cardioverter defibrillator versus amiodarone: eleven-year follow-up of a subset of patients in the Canadian implantable defibrillator study (CIDS). Circulation (2004) 110:112–6.[Abstract/Free Full Text]

[31] Sears SF, Conti JB. Quality of life and psychological functioning of ICD patients. Heart (2002) 87:488–93.[Free Full Text]

[32] Bilge AK, Ozben B, Demircan S, Cinar M, Yilmaz E, Adalet K. Depression and anxiety status of patients with implantable cardioverter defibrillator and precipitating factors. Pacing Clin Electrophysiol (2006) 29:619–26.[CrossRef][Medline]

[33] Whang W, Albert CM, Sears SF, Lampert R, Conti JB, Wang PJ, et al, for the TOVA Study Investigators. Depression as a predictor for appropriate shocks among patients with implantable-cardioverter defibrillators. J Am Coll Cardiol (2005) 45:1090–5.[Abstract/Free Full Text]

[34] Pedersen SS, van Domburg RT, Theuns DAMJ, Jordaens L, Erdman RAM. Type D personality: a determinant of anxiety and depressive symptoms in patients with an implantable cardioverter defibrillator and their partners. Psychosom Med (2004) 66:714–9.[Abstract/Free Full Text]

[35] Sanders GD, Al-Khatib SM, Berliner E, Bigger JT, Buxton AE, Califf RM, et al. Preventing tomorrow's sudden cardiac death today: part II: translating sudden cardiac death risk assessment strategies into practice and policy. Am Heart J (2007) 153:951–9.[CrossRef][Web of Science][Medline]

[36] Brunner-La Rocca HP, Kaiser C, Bernheim A, Zellweger MJ, Jeger R, Buser PT, et al. Cost-effecticeness of drug-eluting stents in patients at high or low risk of major cardiac events in the Basel Stent KostenEffektivitatsTrail (Basket): an 18-months analysis. Lancet (2007) 370:1552–9.[CrossRef][Web of Science][Medline]

[37] You JJ, Woo A, Ko DT, Cameron DA, Mihailovic A, Krahn M. Life expectancy gains and cost-effectiveness of implantable cardioverter/defibrillators for the primary prevention of sudden cardiac death in patients with hypertropic cardiomyopathy. Am Heart J (2007) 154:899–907.[CrossRef][Web of Science][Medline]

[38] Mark DB, Nelson CL, Anstrom KJ, Al-Khatib SM, Tsiatis AA, Cowper PA, et al. Cost-effectiveness of defibrillator therapy or amiodarone in chronic stable heart failure. Circulation (2006) 114:135–42.[Abstract/Free Full Text]

[39] Yoa G, Freemantle N, Calvert MJ, Stirling B, Daubert JC, Cleland GF. The long-term cost-effectiveness of cardiac resynchronization therapy with or without an implantable cardioverter-defibrillator. Eur Heart J (2007) 28:42–51.[Abstract/Free Full Text]

[40] Pedersen SS, van den Broek KC, Sears SF Jr. Psychological intervention following implantation of an implantable defibrillator: a review and future recommendations. Pacing Clin Electrophysiol (2007) 30:1546–54.[Medline]

[41] Sweeney MO, Wathen MS, Volosin K, Abdalla I, DeGroot PJ, Otterness MF, et al. Appropriate and inappropriate ventricular therapies, quality of life, and mortality among primary and secondary prevention implantable cardioverter defibrillator patients: results from the Pacing Fast VT REduces Shock ThErapies (PainFREE Rx II) trial. Circulation (2005) 111:2898–905.[Abstract/Free Full Text]

[42] Groeneveld PW, Matta MA, Suh JJ, Yang F, Shea JA. Quality of life among cardioverter-defibrillator recipients in the primary prevention therapeutic era. Pacing Clin Eletrophysiol (2007) 30:463–71.[CrossRef]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?



This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/5/545    most recent
eun073v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Johansen, J. B.
Right arrow Articles by Mortensen, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johansen, J. B.
Right arrow Articles by Mortensen, P. T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?