Skip Navigation


Europace Advance Access originally published online on March 6, 2008
Europace 2008 10(4):467-468; doi:10.1093/europace/eun055
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/4/467    most recent
eun055v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Arbelo, E.
Right arrow Articles by Medina, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arbelo, E.
Right arrow Articles by Medina, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org


ELECTROPHYSIOLOGY AND ABLATION

Successful slow pathway ablation for atrioventricular nodal re-entrant tachycardia via a hypoplastic inferior vena cava in a patient with an azygos continuation

Elena Arbelo*, Eduardo Caballero and Alfonso Medina

Cardiology Department, Hospital Universitario de Gran Canaria Dr Negrín, Crta. General del Centro 239, Las Palmas de Gran Canaria, 35017 Las Palmas, Spain

Manuscript submitted 20 January 2008. Accepted after revision 13 February 2008.

* Corresponding author. Tel: +34 636 833058; fax: +34 928 450086. E-mail address: elenaarbelo{at}secardiologia.es


    Abstract
 Top
 Abstract
 References
 
Catheter ablation of the slow pathway for atrioventricular nodal re-entrant tachycardia (AVNRT) is not always possible due to congenital or acquired obstruction of the inferior vena cava (IVC). Although a superior access has been proposed as an alternative approach, a poor manoeuvrability and a lower stability of the ablation catheter may be potential problems. We report a case of slow pathway ablation for AVNRT in a patient with an azygos continuation using a hypoplastic but uninterrupted IVC.

Key Words: Hypoplastic inferior vena cava, Azygos continuation, AV nodal re-entrant tachycardia, Catheter ablation

In order to ablate the slow pathway for atrioventricular nodal re-entrant tachycardia (AVNRT), the catheters normally access the heart through the transfemoral route. Unfortunately, this is not always possible because of obstruction of the inferior vena cava (IVC). The congenital absence of the hepatic segment of the inferior IVC is an anatomical variant that may occur in 0.1–0.6% of normal healthy individuals and up to 3% of patients with congenital heart disease.1Go–5Go We report a case of slow pathway ablation in a patient with an azygos continuation using a hypoplastic but uninterrupted IVC.

A 39-year-old woman with a medically refractory history of supraventricular tachycardia in the absence of structural heart disease was admitted for an ablation procedure. Two 5 F quadrapolar catheters were advanced through the right femoral vein. When the first reached the cardiac silhouette, no electrical activity could be recorded nor could the catheter be advanced into the right atrium (RA). An angiography showed the contrast material entering the RA through the superior vena cava, suggesting the interruption of the IVC and the continuation of the azygos (Figure 1A and B). As a consequence, the electrode was positioned through the azygos vein into the RA. However, when the second quadrapolar electrode was advanced, the RA and the His-bundle area were reached without encountering any obstacle, suggesting the permeability of the IVC. A pigtail diagnostic catheter was used to perform an angiography at the azygos vein to corroborate the diagnosis, showing also that the second catheter had accessed the RA through an alternative vessel (Figure 1C and D).


Figure 1
View larger version (86K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 (A and B) Contrast material injected through a long 8 F sheath entering the RA through the azygos continuation of the IVC. (C and D) Contrast material is injected using a pigtail catheter placed in the azygos vein (AP and RAO views). (E) Contrast material injected at the origin of the hypoplastic IVC at the renal level (small inset: contrast material injected at the femoral vein shows the connection between the IVC and a prominent ascending lumbar vein). (F) Contrast material enters the RA through the hypoplastic IVC. (G and H) Position of the ablation catheter (Abl) at the successful site of ablation (LAO and RAO views).

 
With the catheters positioned in the low RA (through the azygos vein) and the His bundle (through the hypoplastic IVC), a programmed electrical stimulation was performed and a supraventricular tachycardia compatible with AVNRT was reproducibly induced.

A 4 mm standard radio frequency ablation catheter (Mariner, Medtronic Inc., MN, USA) was successfully advanced through the hypoplastic IVC using the second quadrapolar catheter as an X-ray guide. The diagnostic catheter was then advanced to the right ventricular apex, and the tip of the ablation catheter was positioned in the posterior portion of the triangle of Koch where radiofrequency current was administered (Figure 1 G-H).

At the end of the procedure, a multipurpose catheter (MP-2, Medtronic Inc.) was used to inject contrast material into the vessel where the ablation catheter had been advanced, confirming the diagnosis of uninterrupted IVC (Figure 1E and F). There were no complications.

The internal right jugular and subclavian veins have been proposed as an alternative approach for the ablation of the slow pathway in the case of infrahepatic obstruction of the IVC. However, the potential drawbacks of a superior access could be the orientation and poor manoeuvrability of the ablation catheter and lower catheter stability, which are essential to avoid complications such as complete AV block.

In our patient, the manipulation of the diagnostic catheter through the azygos continuation of the IVC was difficult and time-consuming, because of its long course and angulation. Fortunately, after advancing one of the quadrapolar catheters through an unsuspected hypoplastic IVC, the ablation catheter was safely positioned through the same vessel, allowing a much finer control of its tip and the successful ablation of the slow AV nodal pathway.

This case report highlights the importance of identifying this type of vascular anomaly and, in particular, of recognizing the existence of a permeable IVC, which allows for the safer ablation of the slow AV nodal pathway.

Conflict of interest: none declared.


    References
 Top
 Abstract
 References
 
[1] Trigaux JP, Vandroogenbroek S, De Wispelaere JF, Lacrosse M, Jamart J. Congenital anomalies of the inferior vena cava and left renal vein: evaluation with spiral CT. J Vasc Interv Radiol (1998) 9:339–45.[Web of Science][Medline]

[2] Bass JE, Redwine MD, Kramer LA, Huynh PT, Harris JH Jr. Spectrum of congenital anomalies of the inferior vena cava: cross-sectional imaging findings. Radiographics (2000) 20:639–52.[Abstract/Free Full Text]

[3] Anderson RC, Adams P Jr, Burke B. Anomalous inferior vena cava with azygos continuation (infrahepatic interruption of the inferior vena cava). Report of 15 new cases. J Pediatr (1961) 59:370–83.[CrossRef][Web of Science][Medline]

[4] Chuang VP, Mena CE, Hoskins PA. Congenital anomalies of the inferior vena cava. Review of embryogenesis and presentation of a simplified classification. Br J Radiol (1974) 47:206–13.[Abstract/Free Full Text]

[5] Mayo J, Gray R, St Louis E, Grosman H, McLoughlin M, Wise D. Anomalies of the inferior vena cava. Am J Roentgenol (1983) 140:339–45.[Free Full Text]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Circ Arrhythm ElectrophysiolHome page
A. Metzner, K.R. J. Chun, D. Kivelitz, and K.-H. Kuck
Successful Transseptal Puncture and Cryoballoon Pulmonary Vein Isolation in Adverse Anatomy: Interrupted Inferior Caval Vein and Azygos Continuation
Circ Arrhythm Electrophysiol, October 1, 2009; 2(5): e24 - e27.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/4/467    most recent
eun055v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Arbelo, E.
Right arrow Articles by Medina, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arbelo, E.
Right arrow Articles by Medina, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?