Skip Navigation


Europace Advance Access originally published online on August 13, 2008
Europace 2008 10(10):1152-1156; doi:10.1093/europace/eun214
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/10/1152    most recent
eun214v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Tomaske, M.
Right arrow Articles by Bauersfeld, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tomaske, M.
Right arrow Articles by Bauersfeld, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org


Implantable cardioverter-defibrillators

Epicardial and pleural lead ICD systems in children and adolescents maintain functionality over 5 years

Maren Tomaske1,*, René Prêtre2, Mariette Rahn2 and Urs Bauersfeld1

1 Division of Paediatric Cardiology, University Children's Hospital, Steinwiesstrasse 75, CH-8032 Zurich, Switzerland; 2 Division of Congenital Cardiovascular Surgery, University Children's Hospital, Zurich, Switzerland

Manuscript submitted 25 May 2008. Accepted after revision 25 July 2008.

* Corresponding author. Tel: +41 44 2667519; fax: +41 44 2667981.E-mail address: maren.tomaske{at}kispi.uzh.ch


    Abstract
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
Aims: The optimal implantable cardioverter defibrillator (ICD) system implant technique has not yet been defined in young patients and those with congenital heart disease (CHD). We describe our 5-year experience with epicardial pacing/sensing leads secured on the left cardiac chambers and a pleural defibrillation lead insertion along the third intercostal space.

Methods and results: Implantable cardioverter defibrillator systems were implanted in 15 children and adolescents (age: 2.9–20.0 years) for primary (n = 11) or secondary (n = 4) prevention. Underlying CHD were hypertrophic (n = 10) or dilative cardiomyopathies (n = 2), primary electrical diseases (n = 2), and transposition of the great arteries (n = 1). Devices were placed in the rectus sheath (n = 5), or within the diaphragm (n = 10). Median defibrillation threshold at implant was 15 J (range: 10–25). During 5 years of follow-up (median: 22 months), nine appropriate and two inappropriate ICD discharges occurred. Four system revisions were required due to device recall, pleural lead dislodgement, epicardial lead fracture, and insulation break. Twelve months after the implantation, defibrillation threshold testing demonstrated stable thresholds of ≤20 J in five patients.

Conclusion: Our 5-year experience demonstrates the efficacy of epicardial and pleural lead ICD systems. Inappropriate shocks and lead failures are observed as in other ICD systems. It represents an alternative implant technique for young and active patients and those without venous access.

Key Words: Implantable cardioverter defibrillator, Congenital heart disease, Implantation technique, Paediatric


    Introduction
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
Implantable cardioverter defibrillators (ICDs) in adults and young patients have proven to be an effective therapy for life-threatening ventricular arrhythmias. Thus, they are increasingly used for the primary and secondary prevention of sudden cardiac death.1Go–3Go However, small vessel size or cardiovascular abnormalities may preclude transvenous leads in young patients and adults with congenital heart disease (CHD).

The optimal ICD system implant technique in the presence of limited venous access to the heart has not yet been defined.4Go–7Go Growth and high physical activity levels with possible physical impact are risk factors for complications in the paediatric population.8Go,9Go

The authors previously published their initial experience describing a new implant technique of an ICD system with abdominal or infracardiac horizontal device position, epicardial pacing and sensing leads, and a pleural defibrillation lead placement in patients.6Go

The purpose of this study was to evaluate the performance of this ICD system implant technique with the inclusion of more patients and a prolonged follow-up.


    Patients and methods
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
Study patients
A total of 15 children and adolescents were prospectively enrolled. Baseline characteristics and indications for ICD therapy are depicted in Table 1. Beta-blocker therapy was received by 13 of the 15 (86%) patients. The study protocol was performed with Institutional Ethics Committee approval, and parental written informed consent was obtained.


View this table:
[in this window]
[in a new window]

 
Table 1 Baseline characteristics at implantable cardioverter defibrillator system implant in 15 patients

 
Implantable cardioverter defibrillator system implantation
As previously described in detail,6Go the surgical access for lead implantation was a muscle sparing left lateral thoracotomy in the forth intercostal space or sternotomy in the case of concomitant cardiac surgery. The defibrillation lead (Medtronic 6937, Medtronic, Inc., Minneapolis, MN, USA) was inserted in a tunnel created along the third intercostal space. Bipolar steroid-eluting epicardial leads (Medtronic CapSure Epi 4968, Medtronic, Inc.) were secured on the free lateral wall of the left ventricle and on the left atrial appendage in the case of dual-chamber ICD systems. In the first five patients, devices were positioned in the rectus muscle sheath. In an attempt to optimize the electrical field, the devices were subsequently placed in a horizontal position within the diaphragm underneath the right ventricle in 10 patients. All devices implanted were manufactured by Medtronic (Medtronic, Inc.), as they enable interrogation of devices in a horizontal intrathoracic position and provide a maximum defibrillation energy of 35 J [Virtuoso DR (n = 6), EnTrust (n = 4), Intrinsic (n = 3), Maximo DR (n = 1), and Concerto (n = 1)].

Data acquisition
Defibrillation thresholds, lead impedances, and sensing and pacing thresholds were measured at the time of implantation. In patients with concomitant cardiac surgery, defibrillation thresholds of 20 J were accepted, and no further testing was carried out at lower energy settings. ICD and clinical follow-up data were obtained at implant, 1 month, and semi-annual intervals thereafter. Defibrillation threshold retesting was scheduled every 12 months after the ICD system implant, provided that ventricular fibrillation was inducible at implant. Chest radiographs were acquired 1 day after ICD implantation and scheduled 12 monthly thereafter for the documentation of stable lead and device positions.

Statistical analysis
Data are expressed as either median (range) or mean (± standard deviation) depending on the distribution pattern of the data evaluated by the Kolmogorov–Smirnov test. Descriptive statistics were applied if appropriate. Wilcoxon signed rank tests were used to compare telemetry data at various follow-up. A P-value less than 0.05 was considered statistically significant.


    Results
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
Implantable cardioverter defibrillator system implantation
No implant complications were observed. Adequate defibrillation thresholds were obtained in 12 patients; in 3 patients with hypertrophic cardiomyopathy, ventricular fibrillation was not inducible. The median lowest tested defibrillation threshold at implant was 15 J (range: 10–25), even when testing was performed immediately after cardiopulmonary bypass surgery (n = 6). A second mediastinal defibrillation lead was used to achieve a defibrillation threshold of 20 J in patients with hypertrophic obstructive cardiomyopathy. Cardiopulmonary bypass surgery for the resection of a subaortic stenosis may have altered defibrillation threshold in this patient.

Telemetry data at various follow-up
Detailed lead performance is depicted in Table 2. Impedances of the pleural defibrillation lead did not change significantly during follow-up. Impedances of the atrial and ventricular epicardial leads were high at implantation and decreased significantly until first follow-up after 1 month. No changes were noted during further follow-up. Likewise, sensing and pacing thresholds of the atrial and ventricular epicardial leads remained constant over time. In nine patients, atrial pacing was required, with predominant (>80%) atrial pacing in two patients. Dual chamber pacing was required in two patients, including biventricular pacing in one patient suffering from complete atrioventricular block and congestive heart failure. All other patients were in sinus rhythm.


View this table:
[in this window]
[in a new window]

 
Table 2 Measured data from implantable cardioverter defibrillator and pacemaker telemetry: at implant and follow-up

 
Defibrillation thresholds
The lowest tested defibrillation thresholds were stable in five patients retested after 12 month [implant: 20 J (15–25) vs. 12 months: 17.5 J (15–20); P = 0.34]. Moreover, two patients were retested at 24 months, and one at 48 months after the ICD system implant. Measurements indicated no change in the previous lowest tested defibrillation thresholds.

Implantable cardioverter defibrillator discharges
During a maximum follow-up of 60 months, nine appropriate ICD discharges leading to the successful termination of ventricular tachycardias were seen in four patients. Charging was aborted twice after spontaneous ventricular tachycardia termination in one patient. Two inappropriate shocks were documented due to sinus tachycardia and T-wave oversensing in two patients.

System revisions
System revisions were required in four patients. Dislodgement of a pleural defibrillation lead in the early learning curve was detected by chest radiography. One ventricular lead insulation break was observed 17 months post-implant. Moreover, after a growth spurt of 20 cm at 31 months post-implant, an atrial and ventricular lead fracture was detected (Figure 1) in an 11-year old girl. All above-mentioned system revisions occurred for devices positioned in the rectus muscle sheath. Additionally, one device exchange was performed after recall.


Figure 1
View larger version (139K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 1 Lead fracture. Radiographically visible fracture of the atrial as well as ventricular leads requiring system revision at 31 months after implantation.

 

    Discussion
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
As in adults, the use of ICD in the paediatric population has proven to be effective in the therapy of life-threatening ventricular arrhythmias.1Go–3Go The optimum positioning of the defibrillation electrode in small patients or those with limited venous access as seen in CHD is still controversial.

The main findings with the new ICD system implant technique were adequate defibrillation thresholds achieved when tested immediately after cardiopulmonary bypass surgery. In all patients retested, lowest tested defibrillation thresholds were stable at or below 20 J. Moreover, sensing and pacing thresholds of the epicardial atrial and ventricular leads remained stable over time.

A main risk for complications in children is related to lead failure with a high incidence of fracture or dislodgement of the defibrillation lead, likely due to physical activity, growth-related distortion, and unfavourable position in terms of exposure to physical impact. The overall incidence of lead failure in adults is 2–3%,10Go whereas in children and adolescents with CHD, the rate of significant complications in recent studies was as high as 21%.1Go,9Go This is in accordance with our findings, with lead failures being the most frequent indication for system revision. However, all observed lead failures in our study cohort occurred for devices positioned in the rectus muscle sheath.

Supraventricular tachycardia, T wave oversensing, and electrode defects are reported to be the main causes for inappropriate ICD therapy. The rate of inappropriate shocks reported in children, adolescents, and young adults with CHD is up to 47%.8Go,9Go,11Go–15Go With this new implant technique in our patient cohort, inappropriate shocks were observed with a comparatively low incidence of 2/11 discharges (18%).

As described previously,5Go,16Go a main difficulty encountered in the paediatric population with CHD is high defibrillation threshold at ICD system implant. To optimize the electrical field, the device was placed in the horizontal position underneath the heart within the diaphragm. Of importance, for six patients in our study cohort with concomitant cardiac surgery, true defibrillation thresholds were not obtained. The lowest energy tested in those was 20 J and was used as a surrogate for true defibrillation thresholds. However, the maximum lowest tested defibrillation threshold was 25 J. Regular defibrillation threshold testing has been proposed during follow-up in the growing patient and those with CHD.16Go Of importance, defibrillation threshold testing in our patient cohort remained stable during follow-up with the maximum lowest tested defibrillation threshold of 20 J.

Previous studies have reported on non-standard implantation techniques with pericardial coils4Go or subcutaneous/epicardial defibrillation leads.5Go,7Go Two of the studies4Go,5Go offer a similar median follow-up to our study. The incidence of inappropriate shocks was higher with pericardial coils [3/8 (38%) patients] and subcutaneous/epicardial leads [4/22 (18%) patients] when compared with our study cohort [2/15 (13%) patients]. Lead failure or migration requiring system revision was comparable between pericardial coils [1/8 (13%) patients], subcutaneous/epicardial leads [4/22 (18%) patients], and our implant technique [3/15 (20%) patients]. However, the small number of patients in all three mentioned studies limits any statistically valid determination of a conclusive statement. With the improved implant technique by means of devices in the infracardiac horizontal position, no lead failures were observed during follow-up. Theoretically, a subpleural insertion provides limited lead stress through cardiac contraction or respiratory movements.

An intra-thoracic, horizontal position of the device underneath the heart limits lead tension, compared with placement in the rectus muscle sheath. The intrathoracic lead and device insertion ensure a safe ICD system position in active patients in the case of physical impact and provide an excellent functional status in terms of arm movements for profession and sports. Moreover, the muscle sparing mini-left axillary approach for left ventricular epicardial lead insertion used in our institution has been associated with a low complication rate, excellent cosmetic results, and stable sensing and pacing thresholds.17Go

However, there are also some potential disadvantages of an infracardiac device placed within the diaphragm. If a device has to be replaced, careful dissection from its pocket closely related to the right ventricle has to be accomplished. So far, infracardiac devices did not have to be replaced in our cohort. No complications, such as pressure on the vena cava inferior, pocket infection, or device migration were observed. Chest radiographs scheduled every 12 months demonstrated stable position of the device.

Clinical implications
With the evolving indications for ICD therapy, there are major advantages of the presented implant technique. Epicardial leads may be ideal for pacing and sensing functions of the ICD system. A superior performance of ventricular sensing was demonstrated for left ventricular epicardial leads.18Go Moreover, the placement of left ventricular leads facilitates left ventricular pacing in patients with a diseased right ventricle2Go as well as biventricular or single-site left ventricular pacing if additional resynchronization therapy is required (Figure 2).19Go

The majority of patients with structural CHD and limited venous access in the need for an ICD therapy are those suffering from chronic pressure or volume overload of the ventricle due to TOF,15Go D-transposition of the great arteries following Mustard and Senning repair,20Go and left ventricular outflow tract obstructions.21Go The risk of sudden death appears to be age-dependent, thereby the need for ICD therapy is primarily increasing in young adults.20Go However, an increasing number of patients with univentricular heart is palliated and may suffer from advanced systemic ventricular function. Implantable cardioverter defibrillator therapy potentially evolves in those children and adolescents with limited venous access and necessitates epicardial lead implantation. Likewise, the intention to preserve the venous access often precludes a transvenous approach and requires epicardial lead implantation.


Figure 2
View larger version (60K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Figure 2 Implantable cardioverter defibrillator and resynchronization therapy. Frontal (A) and lateral (B) chest radiographs of a resuscitated 11-year old girl with arterial switch operation for D-transposition of the great arteries as a neonate and post-surgical complete atrioventricular block are demonstrated. Due to congestive heart failure resulting from aortic valve insufficiency, cardiopulmonary bypass surgery with aortic valve replacement was performed and resynchronization therapy was initiated. Left atrial and biventricular epicardial pacing leads, subpleural placement of the defibrillator electrode and intra-thoracic, horizontal position of the device are displayed.

 
Study limitation
Limitations of the study include the restricted follow-up period, revealing nine effectively terminated malignant arrhythmias in four patients. However, ICD systems were implanted for the primary prevention of sudden death in the majority of our study cohort. Thus, a higher incidence of malignant tachycardia and successful ICD discharges cannot easily be anticipated even in a prolonged follow-up. System revisions were necessary in four patients including one device recall, and one defibrillation lead dislodgement, early in the learning period. As lead dislodgement may have been facilitated by tension from the abdominal (rectus muscle sheath) ICD position, the refined technique with infracardiac horizontal placement of the device was performed at revision.


    Conclusion
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
In conclusion, the implantation of ICD systems with epicardial sensing and pacing leads, and a pleural placement of the defibrillation lead, is feasible and safe in children and adolescents with CHD. An infracardiac horizontal position of the device optimizes the electrical field and results in a safe and protected position. An epicardial and pleural lead ICD system may be an alternative ICD implant technique for young patients and those with CHD without transvenous access.

Conflict of interest: none declared.


    References
 Top
 Abstract
 Introduction
 Patients and methods
 Results
 Discussion
 Conclusion
 References
 
[1] Stefanelli CB, Bradley DJ, Leroy S, Dick M II, Serwer GA, Fischbach PS. Implantable cardioverter defibrillator therapy for life-threatening arrhythmias in young patients. J Interv Cardiol (2002) 6:235–44.[CrossRef]

[2] Walsh EP, Cecchin F. Recent advances in pacemaker and implantable defibrillator therapy for young patients. Curr Opin Cardiol (2004) 19:91–6.[CrossRef][Web of Science][Medline]

[3] Epstein AE, Dimarco JP, Ellenbogen KA, Mark Estes NA III, Freedman RA, Gettes LS, et al. ACC/AHA/HRS 2008 Guidelines for Device-based Therapy of Cardiac Rhythm Abnormalities: Executive Summary. A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons. J Am Coll Cardiol (2008) 51:2085–105.[Free Full Text]

[4] Cannon BC, Friedman RA, Fenrich RA, Fraser CD, McKenzie ED, Kertesz NJ. Innovative technique for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart. Pacing Clin Electrophysiol (2006) 29:181–7.[CrossRef][Medline]

[5] Stephenson EA, Batra AS, Knilans TK, Gow RM, Gradaus R, Balaji S, et al. A multicenter experience with novel implantable cardioverter defibrillator configurations in the pediatric and congenital heart disease population. J Cardiovasc Electrophysiol (2006) 17:41–6.[CrossRef][Web of Science][Medline]

[6] Bauersfeld U, Tomaske M, Dodge-Khatami A, Rahn M, Kellenberger C, Prêtre R. Initial experience with implantable cardioverter defibrillator systems using epicardial and pleural electrodes in pediatric patients. Ann Thorac Surg (2007) 84:303–5.[Abstract/Free Full Text]

[7] Kaltman JR, Gaynor JW, Rhodes LA, Buck K, Shah MJ, Vetter VL, et al. Subcutaneous array with active can implantable cardioverter defibrillator configuration: a follow-up study. Congenit Heart Dis (2007) 2:125–9.[CrossRef][Medline]

[8] Korte T, Köditz H, Niehaus M, Paul T, Tebbenjohanns J. High incidence of appropriate and inappropriate ICD therapies in children and adolescents with implantable cardioverter defibrillator. Pacing Clin Electrophysiol (2004) 27:924–32.[CrossRef][Medline]

[9] Alexander ME, Cecchin F, Walsh EP, Triedman JK, Bevilacqua LM, Berul CI. Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics. J Cardiovasc Electrophysiol (2004) 15:72–6.[Web of Science][Medline]

[10] Link MS, Hill SL, Cliff DL, Swygman CA, Foote CB, Homoud MK, et al. Comparison of frequency of complications of implantable cardioverter-defibrillators in children versus adults. Am J Cardiol (1999) 83:263–6.[CrossRef][Web of Science][Medline]

[11] Love BA, Barrett KS, Alexander ME, Bevilacqua LM, Epstein MR, Triedman JK, et al. Supraventricular arrhythmias in children and young adults with implantable cardioverter defibrillator. J Cardiovasc Electrophysiol (2001) 12:1097–101.[CrossRef][Web of Science][Medline]

[12] Chatrath R, Porter CB, Ackerman MJ. Role of transvenous implantable cardioverter defibrillators in preventing sudden cardiac death in children, adolescents, and young adults. Mayo Clin Proc (2002) 77:226–31.[Abstract/Free Full Text]

[13] Berul CI, Van Hare GF, Kertesz NJ, Dubin AM, Cecchin F, Collins KK, et al. Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients. J Am Coll Cardiol (2008) 51:1685–91.[Abstract/Free Full Text]

[14] Yap SC, Roos-Hesselink JW, Hoendermis ES, Budts W, Vliegen HW, Mulder BJ, et al. Outcome of implantable cardioverter defibrillators in adults with congenital heart disease: a multi-centre study. Eur Heart J (2007) 28:1854–61.[Abstract/Free Full Text]

[15] Khairy P, Harris L, Landzberg MJ, Viswanathan S, Barlow A, Gatzoulis MA, et al. Implantable cardioverter-defibrillators in tetralogy of Fallot. Circulation (2008) 117:363–70.[Abstract/Free Full Text]

[16] Stephenson EA, Cecchin F, Walsh EP, Berul CI. Utility of routine follow-up defibrillator threshold testing in congenital heart disease and pediatric populations. J Cardiovasc Electrophysiol (2005) 16:69–73.[CrossRef][Web of Science][Medline]

[17] Dodge-Khatami A, Kadner A, Dave H, Rahn M, Prêtre R, Bauersfeld U. Left heart atrial and ventricular epicardial pacing through a left lateral thoracotomy in children: a safe approach with excellent functional and cosmetic results. Eur J Cardiothorac Surg (2005) 28:541–5.[Abstract/Free Full Text]

[18] Tomaske M, Gerritse B, Kretzers L, Pretre R, Dodge-Khatami A, Rahn M, et al. A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children. Ann Thorac Surg (2008) 85:1704–11.[Abstract/Free Full Text]

[19] Gasparini M, Bocchiardo M, Lunati M, Ravazzi PA, Santini M, Zardini M, et al. BELIEVE Investigators. Comparison of 1-year effects of left ventricular and biventricular pacing in patients with heart failure who have ventricular arrhythmias and left bundle-branch block: the Bi vs left ventricular pacing: an international pilot evaluation on heart failure patients with ventricular arrhythmias (BELIEVE) multicenter prospective randomized pilot study. Am Heart J (2006) 152:155.e1–e7.

[20] Khairy P, Harris L, Landzberg MJ. Defibrillators in transposition of the great arteries with Mustard and Senning baffles. Heart Rhythm (2007) 4:S95.[CrossRef]

[21] Silka MJ, Hardy BG, Menashe VD, Morris CD. A population-based prospective evaluation of risk of sudden death after operation for common congenital heart defects. J Am Coll Cardiol (1998) 32:245–51.[Abstract/Free Full Text]


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?



This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
10/10/1152    most recent
eun214v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Tomaske, M.
Right arrow Articles by Bauersfeld, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tomaske, M.
Right arrow Articles by Bauersfeld, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?