Europace Advance Access published online on December 22, 2008

Europace, doi:10.1093/europace/eun350
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
11/4/483    most recent
eun350v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Spencker, S.
Right arrow Articles by Müller, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spencker, S.
Right arrow Articles by Müller, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2008. For permissions please email: journals.permissions@oxfordjournals.org


CLINICAL RESEARCH

Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure

Sebastian Spencker*, Nalan Coban, Lydia Koch, Alexander Schirdewan and Dirk Müller

Division of Cardiology, Charité-Campus Benjamin Franklin, Hindenburgdamm 30, 12200 Berlin, Germany

Aims: Lead dysfunctions in implantable cardioverter-defibrillator (ICD) patients can lead to inappropriate shocks or even complete loss of function of the device. Home monitoring (HM) systems are capable of daily data transmissions regarding the device and the lead integrity as well as information concerning anti-arrhythmic therapies. We therefore analysed the data from the Biotronik HM system whether it enables physicians to react quickly on serious ICD malfunctions and to avoid inappropriate shocks.

Methods and results: Fifty-four patients who had to undergo resurgery due to malfunctions of the ICD lead were included. Eleven of them were on HM interrogating the device every night at 3 am. If any adverse event was detected, a fax alert was sent to the clinic and the patients were asked for in-hospital ICD interrogation. The rate of inappropriate shocks and symptomatic pacemaker inhibition due to oversensing was compared with the 43 patients without remote surveillance. HM sent alert messages in 91% of all incidents. All lead failures became obvious because of oversensing of high frequency artefacts. Only in 18%, changes in the pacing impedance were noticed, in all cases preceded by oversensing. Eighty per cent of the patients were asymptomatic at the first onset of oversensing. Only one patient suffered an inappropriate shock as first manifestation of lead failure. Compared with the patients without HM, inappropriate shocks occurred in 27.3% in the HM group vs. 46.5% (P = n.s.). This trend gains statistical significance, if the compound endpoint of symptomatic lead failure consisting of inappropriate shocks and symptomatic pacemaker inhibition due to oversensing is focused: 27.3% event in the HM group vs. 53.4% in the group without HM (P = 0.04). Event messages were despatched in a mean of 54 days after the last ICD interrogation and 56 days before next scheduled visit. Thus, 56 days of reaction time are gained to avoid adverse events.

Conclusion: In 91% of all lead-related ICD complications, the diagnosis could be established correctly by an alert of the HM system. Mostly, the first incident sent was oversensing of artefacts, falsely detected as ventricular fibrillation—the VF zone. The automatic HM surveillance system enables physicians to detect severe lead problems early and to react quickly; thus, it might have a potential to avoid inappropriate shocks due to lead failure and T-wave oversensing.

Key Words: Lead failure, Oversensing, Home monitoring, ICD, Inappropriate shock


* Corresponding author. Tel: +49 3084452349, Fax: +49 3084452256, Email: sebastian.spencker{at}charite.de

Manuscript submitted 13 July 2008. Accepted after revision 19 November 2008.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
H. Burri and D. Senouf
Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators
Europace, June 1, 2009; 11(6): 701 - 709.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
F. Sacher, V. Probst, M. Bessouet, M. Wright, A. Maluski, S. Abbey, P. Bordachar, A. Deplagne, S. Ploux, G. Lande, et al.
Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population
Europace, April 1, 2009; 11(4): 489 - 494.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J. E. Marine
Remote monitoring for prevention of inappropriate implantable cardioverter defibrillator shocks: is there no place like home?
Europace, April 1, 2009; 11(4): 409 - 411.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.