Skip Navigation


Europace Advance Access originally published online on March 16, 2006
Europace 2006 8(4):283-287; doi:10.1093/europace/eul011
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
8/4/283    most recent
eul011v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (3)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Marquie, C.
Right arrow Articles by Kacet, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marquie, C.
Right arrow Articles by Kacet, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2006. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org


PACING

Post-operative use of heparin increases morbidity of pacemaker implantation

C. Marquie*, G. De Geeter, D. Klug, C. Kouakam, F. Brigadeau, O. Jabourek, N. Trillot, D. Lacroix and S. Kacet

CHRUCardiologie ACardiologic Hospital, bl du Pr, Lille 59037 France

Aims The objective of this study is to characterize the incidence of peri-operative severe adverse events (AEs) related to the post-operative use of heparin in patients undergoing pacemaker surgery. Methods and results We retrospectively compared the outcome of 38 patients with mechanical valves (MVs) and 76 patients with atrial fibrillation (AF) with control cases matched for gender, age, and surgical details. Heparin was systematically used post-operatively in MV patients, but left to clinical judgment in AF patients. The relative risk for severe haemorrhagic AEs was 11 (CI 1.5–81.1, P<0.01) in the MV group when compared with matched controls and 8 (CI 1.0–62.5, P<0.05) in the AF group. Overall, the relative risk of heparin use in the post-operative period was 14 (CI 1.88–104, P=0.0006) and the post-operative stay was prolonged from 7 days in this group when compared with control cases (P<0.0001).The variables associated with haemorrhage were the delay to restart heparin after surgery and the presence of an MV.

Conclusion Post-operative use of heparin increases morbidity of pacemaker implantation. A different approach to management of these patients is possible.

Key Words: Pacemaker implantation, Heparin, Mechanical heart valves, Atrial fibrillation, Haemorrhage, Thrombo-embolism, Adverse events


* Corresponding author. Tel: +33 320445038; fax: +33 320446898. E-mail address: c-marquie{at}chru-lille.fr


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur Heart JHome page
C. Romeyer-Bouchard, A. Da Costa, V. Dauphinot, M. Messier, L. Bisch, B. Samuel, P. Lafond, P. Ricci, and K. Isaaz
Prevalence and risk factors related to infections of cardiac resynchronization therapy devices
Eur. Heart J., January 2, 2010; 31(2): 203 - 210.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
J.W.M. van Eck, N.M. van Hemel, P. Zuithof, J.P.M. van Asseldonk, T.L.H.M. Voskuil, D.E. Grobbee, and K.G.M. Moons
Incidence and predictors of in-hospital events after first implantation of pacemakers
Europace, October 1, 2007; 9(10): 884 - 889.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.