Europace Advance Access originally published online on August 17, 2006
Europace 2006 8(10):863-869; doi:10.1093/europace/eul093
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
8/10/863    most recent
eul093v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (7)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Occhetta, E.
Right arrow Articles by Marino, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Occhetta, E.
Right arrow Articles by Marino, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The European Society of Cardiology 2006. All rights reserved. For Permissions, please e-mail: journals.permissions@oxfordjournals.org


ICD

Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias

Eraldo Occhetta*, Miriam Bortnik, Andrea Magnani, Gabriella Francalacci and Paolo Marino

Divisione Clinicizzata di Cardiologia, Facoltà di Medicina e Chirurgia di Novara, Università degli Studi del Piemonte Orientale, Azienda Ospedaliera Maggiore della Carità, Corso Mazzini 18, 28100 Novara, Italy

Aims The development of implantable cardioverter-defibrillators (ICDs) with QRS morphology discrimination and dual-chamber sensing capabilities has improved the differentiation of supraventricular from ventricular tachycardias (VTs). Inappropriate ICD discharges may result from extracardiac signals caused by electromagnetic interference (EMI), because of electric fields and leakage currents from domestic or medical electrical devices, damaged sensing leads, and various cardiac and extracardiac signals that mimic VT and/or ventricular fibrillation. The aim of our study was to determine retrospectively the incidence and clinical relevance of these ICD behaviours and offer possible therapeutic solutions.

Methods and results We have observed inappropriate discharges unrelated to supraventricular arrhythmias in 13 (3.9%) of the 336 patients implanted with ICDs in our centre from 1989 to 2005. Seven patients received inappropriate shocks following exposure to external EMI: improperly grounded electric stove, electrically powered watering system, hydro-massage bath, electrical pruner, electrocautery current during cardiac surgery, transcutaneous electric nerve stimulation. In four patients, spurious discharges were related to internal noise of the ICD system from inappropriate lead connections. In two cases, erroneous antitachycardia therapy was delivered following different body signals oversensing (T-wave oversensing, wide QRS double-counting and myopotentials). In nine patients, non-invasive solutions prevented further inappropriate therapies (avoidance of EMI, malfunctioning atrial lead exclusion, ventricular sensing reprogramming). In four patients, surgical revision of the system was required (lead connections or position revision).

Conclusion In our experience, inappropriate ICD discharges unrelated to supraventricular arrhythmias occurred in about 4% of ICD patients. A careful evaluation of clinical data and telemetric information (lead impedance, sensed R-wave, stored electrograms) is essential in order to understand the nature of inappropriate ICD discharges and to select the most appropriate solution.

Key Words: Implantable cardioverter-defibrillator, Inappropriate therapies, Electromagnetic interference, Oversensing, Troubleshooting


* Corresponding author. Tel: +39 0321 3733413; fax: +39 0321 3733407. E-mail address: occhetta{at}r-j.it


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
G. C. Digby, M. E. Daubney, J. Baggs, D. Campbell, C. S. Simpson, D. P. Redfearn, F. J. Brennan, H. Abdollah, and A. Baranchuk
Physiotherapy and cardiac rhythm devices: a review of the current scope of practice
Europace, July 1, 2009; 11(7): 850 - 859.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
S. Tzeis, G. Andrikopoulos, C. Kolb, and P. E. Vardas
Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks
Europace, November 1, 2008; 10(11): 1256 - 1265.
[Abstract] [Full Text] [PDF]


Home page
Mayo Clin Proc.Home page
J. P. Abenstein
Safety While Swimming in a Sea of Energy
Mayo Clin. Proc., March 1, 2007; 82(3): 276 - 278.
[Full Text] [PDF]


Home page
Mayo Clin Proc.Home page
J. R. Gimbel and J. W. Cox Jr
Electronic Article Surveillance Systems and Interactions With Implantable Cardiac Devices: Risk of Adverse Interactions in Public and Commercial Spaces
Mayo Clin. Proc., March 1, 2007; 82(3): 318 - 322.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.