Skip Navigation

Europace 2005 7(6):509-515; doi:10.1016/j.eupc.2005.04.005
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (6)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Theuns, D. A.M.J.
Right arrow Articles by Jordaens, L. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Theuns, D. A.M.J.
Right arrow Articles by Jordaens, L. J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2005 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.

Defibrillation efficacy testing: Long-term follow-up and mortality

Dominic A.M.J. Theuns*, Tamas Szili-Torok and Luc J. Jordaens

Department of Cardiology, Erasmus MC Rotterdam, The Netherlands

AIMS: Extensive defibrillation threshold testing is no longer necessary to perform as devices have become more effective. We assessed the lowest effective defibrillation (LED) level at implantation and before hospital discharge and related this to outcome.

METHODS AND RESULTS: One hundred and twenty-seven consecutive patients with biphasic shock and active can devices were studied at intraoperative and predischarge testing. A subgroup of 67 patients had ≥3 VF inductions at implant. Improvement was defined when LED decreased by ≥3 J. The LED was significantly higher at implantation compared with predischarge (P < 0.001). Improvement was seen in 73/127 patients (58%). In the group with ≥3 VF inductions, an implantation LED > 9 J was related to a lower LVEF (P < 0.01); 34/67 patients (51%) had improvement in LED. During follow-up, 18/127 patients died, four received heart transplantation. No different outcome was observed in patients with and without improvement. However, for those with ≥3 VF inductions, an independent predictor of mortality was implantation LED > 9 J without improvement on the second test. Safety margin < 10 J was not related to mortality.

CONCLUSION: Repeated defibrillation efficacy testing before hospital discharge may confirm that a relatively high defibrillation energy is required. This is related to a higher mortality in long-term follow-up.

Key Words: arrhythmias, implantable cardioverter defibrillator, sudden death, survival, ventricular fibrillation


*Corresponding author. Erasmus MC, Department of Clinical Electrophysiology, Bd416, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands. Tel.: +31 10 463 2938; fax: +31 10 463 2701. E-mail address: d.theuns{at}erasmusmc.nl


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
J. A. Blatt, J. E. Poole, G. W. Johnson, D. J. Callans, M. H. Raitt, R. K. Reddy, F. E. Marchlinski, R. Yee, T. Guarnieri, M. Talajic, et al.
No Benefit From Defibrillation Threshold Testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial)
J. Am. Coll. Cardiol., August 12, 2008; 52(7): 551 - 556.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
B. Lemke, T. Lawo, M. Zarse, A. Lubinski, U. Kreutzer, J. Mueller, A. Schuchert, S. Mitzenheim, D. Danilovic, T. Deneke, et al.
Patient-tailored implantable cardioverter defibrillator testing using the upper limit of vulnerability: the TULIP protocol
Europace, August 1, 2008; 10(8): 907 - 913.
[Abstract] [Full Text] [PDF]


Home page
ANN INTERN MEDHome page
J. A. Ezekowitz, B. H. Rowe, D. M. Dryden, N. Hooton, B. Vandermeer, C. Spooner, and F. A. McAlister
Systematic Review: Implantable Cardioverter Defibrillators for Adults with Left Ventricular Systolic Dysfunction
Ann Intern Med, August 21, 2007; 147(4): 251 - 262.
[Abstract] [Full Text] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.