Skip Navigation

Europace 2005 7(5):440-446; doi:10.1016/j.eupc.2005.05.006
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Haghjoo, M.
Right arrow Articles by Sadr-Ameli, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haghjoo, M.
Right arrow Articles by Sadr-Ameli, M. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2005 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.

Is the activation potential of Mahaim pathway always a fast potential? Implication for radiofrequency catheter ablation

Majid Haghjoo*, Arash Arya, Zahra Emkanjoo and Mohammad Ali Sadr-Ameli

Department of Pacemaker and Electrophysiology, Rajaie Cardiovascular Medical and Research Center, School of Medicine, Iran University of Medical Sciences Tehran, Iran

INTRODUCTION: Accessory pathways (AP) exhibiting Mahaim physiology are amenable to radiofrequency (RF) catheter ablation. The recording of an AP potential is an excellent guide for selection of ablation site. The purpose of this study is to determine whether the pathway potential is always a fast potential.

METHODS: Ten patients (six females, mean age, 30±12 years) with preexcited tachycardias involving a Mahaim pathway underwent electrophysiological study and subsequent attempts at RF ablation. Mahaim potentials (M-potential) recorded at the site of successful ablation were reviewed and classified by at least two reviewers.

RESULTS: In all patients, Mahaim pathways were characterized as atriofascicular types. The M-potential was fast in seven patients (group one), and slow in the remaining patients (group two). All group two patients had a history of prior failed ablation. Atrial electrograms were recorded closer to the QRS onset in group one. Atrium to fast M-potential (42±15 ms) was shorter than atrium to slow M-potential (83±12 ms, P=0.03) but M-potentials were recorded with similar distance before local ventricular electrogram (P=NS). Ablation was successful in all patients with mean of 2.9±1.4 RF applications per patient. Ablation data were similar between the two groups (P=NS). No complications occurred. During 12 months of follow-up, no recurrence was observed.

CONCLUSION: Our results illustrated that the activation potential of Mahaim pathways is not always a fast potential. One-third of Mahaim pathways can be mapped and ablated when the slow type of M-potential was used as a target for ablation. We also confirmed high efficacy of catheter ablation of Mahaim pathways guided by activation potentials.

Key Words: Mahaim pathway, catheter ablation, activation mapping, pathway potential


*Corresponding author. Department of Pacemaker and Electrophysiology, Rajaie Cardiovascular Medical and Research Center, Mellat Park, Vali-e-Asr Avenue, Tehran 1996911151, Iran (PO Box 15745-1341). Tel.: +98 21 239 22971; fax: +98 21 204 8174. E-mail address: haghjoo{at}rhc.ac.ir (M. Haghjoo).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.