Europace 2005 7(1):67-72; doi:10.1016/j.eupc.2004.11.002
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Nash, A.
Right arrow Articles by Çeliker, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nash, A.
Right arrow Articles by Çeliker, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2005 The European Society of Cardiology. Published by Elsevier Ltd. All rights reserved.

Rejection of atrial sensing artifacts by a pacing lead with short tip-to-ring spacing

A. Nasha,*, G. Fröhligb, M. Taborskyc, E. Stammwitzd, F. Marue, L.H.M. Bouwensf and C. Çelikerg

aDepartment of Cardiology, The Southwest Cardiothoracic Centre, Derriford Hospital Plymouth PL6 8DH, UK; bUniversitätskliniken des Saarlandes Homburg/Saar, Germany; cNemocnice Na Homolce Prague, Czech Republic; dKreiskrankenhaus Kardiologie Leer, Germany; eDanderyds Sjukhus Medicinkliniken Danderyd, Sweden; fDeventer Ziekenhuis Deventer, The Netherlands; gInstitute of Cardiology of University of Istanbul Istanbul, Turkey

AIMS: The ability of a new pacing lead design, with a 10 mm tip-to-ring spacing, to facilitate rejection of sensed far field R-waves and myopotentials was evaluated.

METHODS AND RESULTS: Measurements were performed in 66 patients. The occurrence of far field R-wave sensing and myopotential sensing was determined by means of the surface ECG and the ECG markers provided by the pacemaker. At an atrial sensitivity of 0.25 mV and an atrial blanking of 50 ms far field R-wave sensing was observed in 12 patients (18.2%) and at an atrial sensitivity of 1.0 mV no far-field R-wave sensing was observed. Myopotentials were sensed in 3 patients. In all patients the measured P-wave amplitude was at least twice the estimated amplitude of the far field R-wave at an atrial blanking of 50 ms.

CONCLUSION: The results from this study show that a small tip-to-ring spacing allows for programming of a high atrial sensitivity and short atrial blanking with an acceptably low risk for atrial artifact sensing.

Key Words: myopotentials, far field R-wave sensing, atrial leads, tip-to-ring spacing


*Corresponding author. Tel.: +44 1752 792 661; fax: +44 1752 763 078. E-mail address: tony{at}cammedcentre.demon.co.uk (A. Nash).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
J. W.H. Fung, J. Sperzel, C. M. Yu, J. Y.S. Chan, R. N. Gelder, M. X. Yang, R. Rooke, P. Boileau, and G. Frohlig
Multicenter clinical experience with an atrial lead designed to minimize far-field R-wave sensing
Europace, May 1, 2009; 11(5): 618 - 624.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. Lewicka-Nowak, A. Kutarski, A. Dabrowska-Kugacka, P. Rucinski, P. Zagozdzon, and G. Raczak
Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing
Europace, February 1, 2008; 10(2): 138 - 146.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A.J. Camm, N. Sulke, N. Edvardsson, P. Ritter, B.A. Albers, J.H. Ruiter, T. Lewalter, P.A. Capucci, E. Hoffmann, and on behalf of the AFTherapy investigators
Conventional and dedicated atrial overdrive pacing for the prevention of paroxysmal atrial fibrillation: the AFTherapy study
Europace, December 1, 2007; 9(12): 1110 - 1118.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
I. Zupan, L. Lipar, D. Zizek, W. Boute, M. Vidmar, T. Gabrijelcic, P. Rakovec, and A. Brecelj
Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients
Europace, October 1, 2006; 8(10): 855 - 858.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.