Skip Navigation

Europace 2004 6(6):617-624; doi:10.1016/j.eupc.2004.08.001
© 2004 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Przybylski, A.
Right arrow Articles by Szwed, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Przybylski, A.
Right arrow Articles by Szwed, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Verification of implantable cardioverter defibrillator (ICD) interventions by nonlinear analysis of heart rate variability – preliminary results

Andrzej Przybylskia,*, Rafal Baranowskia, Jan Jacek Zebrowskib and Hanna Szweda

aInstitute of Cardiology Warsaw, Poland; bFaculty of Physics, Warsaw University of Technology Poland

AIMS: Conventional ICD algorithms yield approximately 10–30% of spurious interventions. Our aim was to check whether nonlinear dynamics methods might be useful in the verification of ICD interventions.

METHODS AND RESULTS: We extracted 190 consecutive RR files (approximately 2000–9000 RR intervals long) from the ICDs of 70 patients (36 with coronary artery disease, 8 with hypertrophic cardiomyopathy, 19 with dilated cardiomyopathy and 7 with other diseases). The 3D phase space trajectories in delay coordinates, window pattern entropy, and algorithmic complexity of the RR intervals were examined within a 50 beat sliding window. Data were not filtered for arrhythmia and artefacts. Of the 83 recordings with appropriate interventions 79 were correctly recognised in a blind test. Two interventions were not identified in patients with fast atrial fibrillation and two in cases of complex and frequent forms of arrhythmia. There were nine spurious interventions. In all except one case (atrial fibrillation with a fast ventricular response) the analysis by nonlinear methods showed that the intervention was not necessary. All of the 98 control recordings were correctly identified in the blind test.

CONCLUSIONS: The results show that nonlinear dynamics methods may be used to supplement the existing ICD detection algorithms to enhance the detection success rate.

Key Words: implantable cardioverter defibrillators, nonlinear dynamics, heart rate variability


*Corresponding author. Spartanska 1 02-637 Warsaw, Poland. Tel.: +48 22 8441358; fax: +48 22 8449510. E-mail address: przybylski{at}eko.net.pl (A. Przybylski).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ptjournalHome page
R. T Harbourne and N. Stergiou
Movement Variability and the Use of Nonlinear Tools: Principles to Guide Physical Therapist Practice
Physical Therapy, March 1, 2009; 89(3): 267 - 282.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.