Skip Navigation

Europace 2004 6(4):273-286; doi:10.1016/j.eupc.2004.02.005
© 2004 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (11)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Aliot, E.
Right arrow Articles by Ripart, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aliot, E.
Right arrow Articles by Ripart, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Arrhythmia detection by dual-chamber implantable cardioverter defibrillators

A review of current algorithms

Etienne Aliota,*, Rémi Nitzschéb and Alain Ripartb

aNancy University Hospital Nancy, France; bELA Medical, Le Plessis-Robinson France

This article reviews the arrhythmia detection criteria currently available in dual-chamber implantable cardioverter defibrillators (ICDs), and describes the implementation and performance of various detection algorithms. Nearly all criteria implemented in single-chamber devices appear to have been included in dual-chamber ICDs. However, two different strategies can be distinguished: the first adds dual-chamber inhibition criteria to a single-chamber detection configuration; the second is a new approach entirely based on a dual-chamber detection scheme. Despite widely available clinical data, an analysis of the implemented detection indexes, arrhythmia characteristics (induced vs spontaneous, minimum duration), device programming (detection rate, programme maintenance and tuning during follow-up), and different storage capabilities among various ICD models, leaves the results of these studies ultimately ambiguous. New algorithms are under study, but only protocols using a single set of arrhythmias and the same programming for all devices may allow relevant comparisons of the performances of detection algorithms. Furthermore, a criterion is required to distinguish reliably between haemodynamically stable and unstable tachycardias, not simply based on rate, but including the underlying cardiac function.

Key Words: implantable cardioverter defibrillator, dual-chamber, arrhythmia detection algorithm


*Corresponding author. Service Cardiologie, Hôpital Brabois, Rue du Morvan, 54500 Vandoeuvre-les-Nancy, France. Tel.: +33-383-153244; fax: +33-383-153856. E-mail address: E-mail address: e.aliot{at}chu-nancy.fr (E. Aliot).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
S. Tzeis, G. Andrikopoulos, C. Kolb, and P. E. Vardas
Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks
Europace, November 1, 2008; 10(11): 1256 - 1265.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Boriani, E. Occhetta, S. Cesario, S. Grossi, M. Marconi, G. Speca, P. Silvestri, M. Biffi, M. Bortnik, C. Martignani, et al.
Contribution of morphology discrimination algorithm for improving rhythm discrimination in slow and fast ventricular tachycardia zones in dual-chamber implantable cardioverter-defibrillators
Europace, August 1, 2008; 10(8): 918 - 925.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
G. Boriani, R. Ricci, T. Toselli, R. Ferrari, A. Branzi, and M. Santini
Implantable cardioverter defibrillators: from evidence of trials to clinical practice
Eur. Heart J. Suppl., December 1, 2007; 9(suppl_I): I66 - I73.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. H. Schoenfeld
Contemporary Pacemaker and Defibrillator Device Therapy: Challenges Confronting the General Cardiologist
Circulation, February 6, 2007; 115(5): 638 - 653.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.