Skip Navigation

Europace 2003 5(2):199-205; doi:10.1053/eupc.2002.0289
© 2003 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (7)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Nürnberg, J.-H.
Right arrow Articles by Lange, P. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nürnberg, J.-H.
Right arrow Articles by Lange, P. E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Antibradycardia pacing in patients with congenital heart disease: experience with automatic threshold determination and output regulation (AutocaptureTM)

J.-H. Nürnberg, H. Abdul-Khaliq, P. Ewert and P. E. Lange

Department of Congenital Heart Disease/Pediatric Cardiology, German Heart Institute Berlin Augustenburger Platz 1, D-13353, Berlin

AIMS: The purpose of this study was to reevaluate whether St Jude Medical's AutocaptureTM algorithm (AC) with beat-to-beat capture confirmation, automatic pacing threshold determination and output adjustment can be applied to paced patients with congenital heart disease (CHD).

METHODS AND RESULTS: 30 patients with CHD received a transvenous (group A: n=22) or epicardial (group B: n=8) single (n=7) or dual chamber (n=23) AC pacemaker for antibradycardia pacing. As a safe AC function is ensured only if a sufficient evoked response (ER) and a low lead polarization amplitude (LPA) are present, these parameters were reevaluated from 112 follow-up studies with respect to AC-function. In all but one transvenous system AC correctly functioned. AC was recommended in 5/8 patients with epicardial leads but correct AC function was preserved in only 3 patients.

CONCLUSION: These data suggest that the application of the AC algorithm is safe in patients with CHD when transvenous leads are used. Whether appropriate AC function is possible with epicardial leads needs individual verification.

Key Words: Congenital heart disease, bradycardia, pacemaker, autocapture, stimulation threshold, evoked response


Correspondence: Jan-Hendrik Nürnberg, Department of Congenital Heart Disease/Pediatric Cardiology, German Heart Institute Berlin, Augustenburger Platz 1, D-13353 Berlin, Germany. Tel.: +49-30-4593 2800; Fax: +49-30-4593 2900; E-mail: nuernberg{at}dhzb.de


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
M. S. Silvetti, A. De Santis, S. Marcora, T. De Santo, N. Grovale, and F. Drago
Circadian pattern of atrial pacing threshold in the young
Europace, February 1, 2008; 10(2): 147 - 150.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. Tomaske, P. Harpes, R. Pretre, A. Dodge-Khatami, and U. Bauersfeld
Long-term experience with AutoCapture(R)-controlled epicardial pacing in children
Europace, August 1, 2007; 9(8): 645 - 650.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. Çeliker, N. Ceviz, and O. Küçükosmanoglu
Long-term results of endocardial pacing with AutocaptureTM threshold tracking pacemakers in children
Europace, January 1, 2005; 7(6): 569 - 575.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. I. Cohen, K. Buck, R. E. Tanel, V. L. Vetter, L. A. Rhodes, J. Cox, T. Sheldon, and L. Ruetz
Capture management efficacy in children and young adults with endocardial and unipolar epicardial systems,
Europace, January 1, 2004; 6(3): 248 - 255.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.