Skip Navigation

Europace 2003 5(1):33-37; doi:10.1053/eupc.2002.0278
© 2003 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Sulke, N.
Right arrow Articles by Paul, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sulke, N.
Right arrow Articles by Paul, V.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

The effect of endocardial defibrillator shocks on basic atrial electrophysiology in man

Is post cardioversion atrial electrical ‘remodelling’ artefact?

N. Sulke1, P. Spurrell1, K. Kamalvand1, A. Mitchell1, M. Higson1, J. Gill2 and V. Paul3

1Department of Cardiology, Eastbourne General Hospital East Sussex, U.K.; 2Department of Cardiology, Guy’s and St Thomas’ NHS Trust London, U.K.; 3Department of Cardiology, St Peter’s Hospital Chertsey, Surrey, U.K.

AIMS: To determine the effect of an endocardial DC shock on the basic electrophysiology of the human atrium if delivered in sinus rhythm.

METHODS AND RESULTS: A 5J endocardial R wave synchronized DC shock was delivered in 10 patients in stable sinus rhythm during ICD implantation for ventricular arrhythmias. There was no prior history of atrial fibrillation. Monophasic action potential duration (APD) and atrial effective refractory periods (AERP) were evaluated before, 1 min post DC shock, and 15 min post shock. These parameters were assessed at basic cycle lengths and at atrial paced cycle lengths of 600 ms and 400 ms at two right atrial sites; mid lateral right atrial wall (MRLA) and the right atrial appendage (RAA). There were no significant differences in APD 90, AERP or atrial refractory dispersion at any site or drive cycle length before, immediately after or 15 min after shock delivery.

CONCLUSIONS: There are no significant changes in basic electrophysiological parameters following a DC shock delivered in sinus rhythm in patients with no prior history of atrial fibrillation. This suggests that atrial electrical remodelling occurs as a result of atrial fibrillation and is unrelated to shock artefact.

Key Words: Atrial fibrillation, atrial electrical remodelling, DC cardioversion, monophasic action potentials, atrial effective refractory period


Correspondence: Dr Neil Sulke, Department of Cardiology, Eastbourne General Hospital, Kings Drive, Eastbourne, East Sussex, BN21 2UD, U.K. Tel.: +44 1323 435869; Fax: +44 1323 435821; E-mail: sulke{at}btinternet.com


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.