Skip Navigation

Europace 2002 4(3):317-324; doi:10.1053/eupc.2002.0239
© 2002 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (3)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Porciani, M. C.
Right arrow Articles by Padeletti, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Porciani, M. C.
Right arrow Articles by Padeletti, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


REGULAR ARTICLES

Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: an echo-Doppler evaluation

Maria Cristina Porciani, Alessandra Sabini, Andrea Colella, Antonio Michelucci, Nicola Musilli, Paolo Pieragnoli and Luigi Padeletti

Institute of Internal Medicine and Cardiology, University of Florence Florence, Italy

AIMS: Biventricular pacing (BVP) can improve haemodynamics in patients with dilated cardiomyopathy (DCM) and left bundle branch block by reducing interventricular delay (IVD). Since in DCM interatrial delay (IAD) and IVD frequently coexist, the aim of this study was to test the hypothesis that IVD reduction associated with IAD produces an imbalance between the programmed right atrioventricular (AV) delay and the effective AV delay on the left, and that interatrial septum pacing (IASP) combined with BVP overcomes this adverse effect.

METHODS AND RESULTS: IAD, IVD, left and right mechanical atrioventricular delay (L-RMAVD) were measured by echo-Doppler in 29 patients with BVP: 17 patients (Group A) had the atrial lead in the right atrial appendage, 12 patients (Group B) who experienced paroxysmal atrial fibrillation had the atrial lead on the interatrial septum. In Group A, LMAVD was significantly shorter than RMAVD (172±24 vs 207±24 ms, P< 0·002), IAD was significantly longer than IVD (52±24 vs 21±18 ms, P< 0·0001). In Group B, no differences were observed between LMAVD and RMAVD (187±32 vs 185±28 ms, NS), and between IAD and IVD (11±12 vs 13±16 ms, NS).

CONCLUSIONS: IAD produces different left and right atrioventricular sequences in BVP. IASP combined with BVP, by resynchronizing both atria and ventricles, is able to avoid this adverse effect.

Key Words: Biventricular pacing, atrioventricular mechanical delay, interatrial delay, interatrial septum pacing, echo-Doppler


Correspondence: Maria Cristina Porciani, MD, Institute of Internal Medicine and Cardiology, University of Florence, Florence, Italy, Viale Morgagni 85, 50134 Florence, Italy. Tel: + 39 055 4277634; Fax: + 39 055 4378638; E-mail: c.porciani{at}dfc.unifi.it


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
S. S. Barold, A. Ilercil, and B. Herweg
Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization
Europace, November 1, 2008; 10(suppl_3): iii88 - iii95.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
S S. Barold and B. Herwerg
Pacing in heart failure: how many leads and where?
Heart, January 1, 2008; 94(1): 10 - 12.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.