Skip Navigation

Europace 2002 4(3):311-315; doi:10.1053/eupc.2002.0235
© 2002 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Christ, T.
Right arrow Articles by Ravens, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Christ, T.
Right arrow Articles by Ravens, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


REGULAR ARTICLES

Rate-adaptive pacing using intracardiac impedance shows no evidence for positive feedback during dobutamine stress test

Torsten Christ1, Matthias Schier3, Arne Brattström3, Gerhardt Muth2, Andreas Hartmann2, Dobromir Dobrev1 and Ursula Ravens1

1Department of Pharmacology and Toxicology, Medical Faculty, University of Technology Dresden, Germany; 2Department of Internal Medicine, St. George's Hospital Leipzig, Germany; 3Department of Biomedical Engineering, Friedrich-Alexander-University Erlangen-Nürnberg, Germany

BACKGROUND: The Inos2 DDDR pacemaker senses unipolar intracardiac impedance signals for adapting heart rate to meet the haemodynamic needs of physical activity. Theoretically, such pacing devices could be limited by positive feedback since increase in beating frequency per se enhances contractility. We have addressed this problem in patients with chronotropic incompetence who were subjected to a pharmacological stress test.

METHODS AND RESULTS: Twelve patients with chronically implanted Inos2 DDDR pacemakers were studied using the standard protocol of stress echocardiography. Most of the patients reached the programmable maximum closed-loop rate during the incremental dobutamine challenge. The time courses for increase in as well as for recovery of heart rate were not different from control patients receiving routine diagnostic stress echocardiography.

CONCLUSIONS: In patients implanted with the Inos2 DDDR pacemaker acute stimulation with intravenous dobutamine leads to a robust increase in paced heart rate without any evidence of positive feedback. Copyright 2002 The European Society of Cardiology. Published by Elsevier Science Ltd. All rights reserved.

Key Words: Closed-loop stimulation, rate adaptive pacing, contractility


Correspondence: Dr med. Torsten Christ, Institut für Pharmakologie und Toxikologie, Fetscherstr. 74, D-01309 Dresden, Germany. Tel: +493514586279; Fax: +493514586315; E-mail: Christ{at}rcs.urz.tu-dresden.de


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.