Skip Navigation

Europace 2001 3(4):299-303; doi:10.1053/eupc.2001.0187
© 2001 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Özmen, F.
Right arrow Articles by Kes, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Özmen, F.
Right arrow Articles by Kes, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


ELECTROPHYSIOLOGY

Effect of balloon-induced acute ischaemia on P wave dispersion during percutaneous transluminal coronary angioplasty

F. Özmen, E. Atalar, K. Aytemir, N. Özer, T. Açil, K. Övünç, S. Aksöyek and S. Kes

Hacettepe University School of Medicine, Cardiology Departments Ankara, Turkey

Abstract

AIMS: P wave dispersion is a recent ECG marker that reflects discontinuous and inhomogeneous conduction of sinus impulses, which has been studied in a limited number of cardiac conditions. The aim of our study was to investigate the effects of angioplasty induced-ischaemia on atrial conduction abnormalities as estimated by P maximum and P dispersion.

METHODS AND RESULTS: The study consisted of 67 consecutive patients (41 men, mean age 58±11 years) with 1-vessel coronary artery disease who underwent elective single vessel coronary angioplasty (left anterior descending (LAD) coronary artery in 28 patients, the right coronary artery (RCA) in 22 patients and the left circumflex coronary artery (LCx) in 17 patients. All patients underwent 12-lead surface ECG before the first inflation (baseline) and then 60 s after intra-coronary balloon inflation. The maximum P wave duration, the minimumP wave duration, and P wave dispersion (Pd=Pmax–Pmin) were calculated from 12-lead surface ECGs.

Baseline P wave duration measurements were not significantly different among the patients with LAD, RCA and LCx coronary artery disease (P> 0·05). P dispersion and P maximum were significantly higher during balloon occlusion compared with the baseline condition in all three types of coronary dilatation procedures. However,P minimum was not found to differ between baseline and during balloon occlusion (P> 0·05).

CONCLUSION: The prolongation of P wave dispersion may be a useful and simple additional marker for myocardial ischaemia.

Key Words: P wave dispersion, P wave duration, induced-ischaemia


Correspondence: Enver Atalar, Konutkent II, C3/A Blok No. 16, Çayyolu, 06530, Ankara, Turkey. E-mail: enveratalar{at}hotmail.com


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur J Heart FailHome page
K. Senen, H. Turhan, A. R. Erbay, N. Basar, A. S. Yasar, O. Sahin, and E. Yetkin
P-wave duration and P-wave dispersion in patients with dilated cardiomyopathy
Eur J Heart Fail, August 1, 2004; 6(5): 567 - 569.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. K. Batur, A. Yildirir, O. Onalan, G. Kabakci, L. Tokgozoglu, and A. Oto
Angioplasty induced myocardial ischaemia prolongs the signal-averaged P-wave duration in single vessel coronary artery disease
Europace, January 1, 2002; 4(3): 289 - 293.
[Abstract] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.