Skip Navigation

Europace 2001 3(3):181-186; doi:10.1053/eupc.2001.0171
© 2001 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (12)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Theuns, D.
Right arrow Articles by Jordaens, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Theuns, D.
Right arrow Articles by Jordaens, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Initial clinical experience with a new arrhythmia detection algorithm in dual chamber implantable cardioverter defibrillators

D. Theuns, A. P. Klootwijk, G. P. Kimman, T. Szili-Török, J. R. T. C. Roelandt and L. Jordaens

Department of Cardiology Thoraxcentre Rotterdam, The Netherlands

AIM: Inappropriate therapy, due to poor discrimination of supraventricular tachycardia (SVT) from ventricular tachycardia (VT) remains a major problem in patients with an implantable cardioverter defibrillator (ICD). Theoretically, the addition of atrial sensing in discrimination algorithms should improve this differentiation. The aim of the study is to evaluate the performance of a new tachycardia discrimination algorithm, SMART DetectionTM.

METHODS AND RESULTS: Twenty-six patients received a non-thoracotomy ICD system (Phylax AV, Biotronik, Germany). All documented spontaneous arrhythmia episodes were analyzed.

During a mean follow-up of 8 months, a total number of 139 events with stored electrograms were recorded in 12 patients. The final diagnosis was ventricular fibrillation (VF) or polymorphic VT (n=20), monomorphic VT (n=69), SVT (n=26), other ventricular arrhythmia (n=3) and T wave oversensing (n=21). In 6 episodes a dual tachycardia was present. Considering SVT episodes, inappropriate therapy occurred in 2 cases of atrial flutter due to stable ventricular rate (<30 ms), 1 case of atrial tachycardia and 2 cases of sinus tachycardia due to a sudden onset (>10%).

CONCLUSION: With the SMART DetectionTM algorithm, discrimination of VT from SVT achieved a sensitivity of 100%, with an accuracy of 95·6% for all ventricular arrhythmias. In the case of SVT, the algorithm appropriately detected and inhibited therapy in 88% of atrial fibrillation.

Key Words: Implantable defibrillator, dual chamber sensing, atrial fibrillation, inappropriate ICD therapy, detection criteria.


Correspondence: L. Jordaens, Thoraxcentre, Dr. Molewaterplein 40, 3015 GD Rotterdam, The Netherlands. E-mail: jordaens{at}card.azr.nl


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
S. Tzeis, G. Andrikopoulos, C. Kolb, and P. E. Vardas
Tools and strategies for the reduction of inappropriate implantable cardioverter defibrillator shocks
Europace, November 1, 2008; 10(11): 1256 - 1265.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. A. Friedman, R. L. McClelland, W. R. Bamlet, H. Acosta, D. Kessler, T. M. Munger, N. G. Kavesh, M. Wood, E. Daoud, A. Massumi, et al.
Dual-Chamber Versus Single-Chamber Detection Enhancements for Implantable Defibrillator Rhythm Diagnosis: The Detect Supraventricular Tachycardia Study
Circulation, June 27, 2006; 113(25): 2871 - 2879.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
D. A.M.J. Theuns, A. P. J. Klootwijk, D. M. Goedhart, and L. J.L.M. Jordaens
Prevention of inappropriate therapy in implantable cardioverter-defibrillators: Results of a prospective, randomized study of tachyarrhythmia detection algorithms
J. Am. Coll. Cardiol., December 21, 2004; 44(12): 2362 - 2367.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
C. Kouakam, S. Kacet, J.-R. Hazard, A. Ferraci, H. Mansour, P. Defaye, J.-M. Davy, M. Lambiez, and on behalf of the Ventak AV Investigators
Performance of a dual-chamber implantable defibrillator algorithm for discrimination of ventricular from supraventricular tachycardia
Europace, January 1, 2004; 6(1): 32 - 42.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
E. Aliot, Rém. Nitzsché, and A. Ripart
Arrhythmia detection by dual-chamber implantable cardioverter defibrillators: A review of current algorithms
Europace, January 1, 2004; 6(4): 273 - 286.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
D. A. M. J. Theuns, J. C. J. Res, and L. J. Jordaens
Home monitoring in ICD therapy: future perspectives
Europace, January 1, 2003; 5(2): 139 - 142.
[Abstract] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.