Skip Navigation

Europace 2000 2(1):60-65; doi:10.1053/eupc.1999.0062
© 2000 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Rosenheck, S.
Right arrow Articles by Leibowitz, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rosenheck, S.
Right arrow Articles by Leibowitz, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Artifacts recorded through failing bipolar polyurethane insulated permanent pacing leads

S. Rosenheck, Z. Sharon and D. Leibowitz

Cardiology Unit and Department of Medicine, Hadassah University Hospital Mount Scopus, Jerusalem, Israel

Pacing failure in bipolar systems using polyurethane insulated leads may be frequent depending on the type of polyurethane and can cause oversensing and or failure to capture. The reason for this failure is often breakage in the inner insulation. The aim of this study was to evaluate the signals created by such a short circuit. Thirty-seven patients were included in the study, 13 with failing leads with polyurethane 80A insulation, 14 with old but normally functioning leads and 10 patients with new leads. Artifacts in the form of spikes were recorded, during surgical revision, from 11 patients with failing leads (84·6%). In patients with normally functioning leads and newly implanted leads no artifacts were recorded. A significant decrease in impedance of 373·4 Ohms (99% confidence intervals 286·4–460·4,P <0·05) was noted in the failing leads compared with a decrease of only 113·0 Ohms (99% confidence intervals 6·5–219·6, P<0·01) in the control leads. The difference between the groups was highly significant. In 10 newly implanted and five normally functioning bipolar ventricular leads similar artifacts could be created by making intermittent contact between the proximal lead connections. Thus, artifacts could be recorded from failing leads and from intact leads with artificial intermittent connection at the proximal end. Our results suggest that the failure is caused by a short circuit in the lead. This finding may have important clinical applications in the follow-up of bipolar pacing and defibrillation leads.

Key Words: Polyurethane insulation, failing leads, lead follow-up, sensing signals, artifacts


Correspondence: Shimon Rosenheck, MD, Cardiology Unit, Hadassah University Hospital Mount Scopus, PO Box 24035, Jerusalem 91240, Israel.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
F. Aliyev, C. Celiker, C. Turkoglu, and O. Abaci
Unusual electrocardiographic presentation of pacemaker battery depletion with lead failure: pacing spike, artefact or native QRS? A short communication
Europace, July 1, 2008; 10(7): 888 - 889.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.