Skip Navigation


Europace Advance Access originally published online on March 11, 2009
Europace 2009 11(4):502-506; doi:10.1093/europace/eup048
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
11/4/502    most recent
eup048v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Morgan, J. M.
Right arrow Articles by Roberts, P. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Morgan, J. M.
Right arrow Articles by Roberts, P. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2009. For permissions please email: journals.permissions@oxfordjournals.org


Pacing and CRT

Targeted left ventricular endocardial pacing using a steerable introducing guide catheter and active fixation pacing lead

John M. Morgan*, Paul A. Scott, Nicholas G. Turner, Arthur M. Yue and Paul R. Roberts

Wessex Cardiothoracic Unit, Southampton University Hospitals, Tremona Road, Southampton SO16 6YD, UK

Aims: Cardiac resynchronization therapy via the coronary sinus (CS) is not always possible. Left ventricular (LV) endocardial lead placement is a potential alternative. The purpose of this study was to assess the feasibility of endocardial LV pacing using a steerable lead introducer and active fixation polyurethane lead.

Methods and results: Endocardial LV lead placement was attempted in nine patients (seven males, age 48–77 years) in whom transvenous CS lead placement had failed. Trans-septal puncture and septal dilatation were performed via the femoral route. A steerable introducer catheter was advanced across the septal puncture site from the right or left subclavian vein into the LV. An active fixation polyurethane lead was then implanted into the high postero-lateral aspect of the LV endocardial wall. All patients were anticoagulated following implant. Successful LV lead placement was achieved in eight patients. There were no acute complications and no embolic events during follow-up (1–32 months). All implanted patients responded well with either improvement in New York Heart Association class or maintenance of symptomatic improvement that had previously been conferred by LV epicardial pacing.

Conclusion: Targeted LV endocardial pacing is a potential alternative to CS pacing and warrants a trial to characterize long-term benefits and risks.

Key Words: Left ventricular endocardial pacing, Cardiac resynchronization, Heart failure


* Corresponding author. Tel: +44 2380 796240, Fax: +44 2380 796614, Email: jmm{at}hrclinic.org

Manuscript submitted 18 December 2008. Accepted after revision 31 January 2009.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
P. A. Scott, P. R. Roberts, and J. M. Morgan
Trans-septal left ventricular endocardial pacing through a persistent left-sided superior vena cava
Europace, December 1, 2009; 11(12): 1709 - 1711.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.