Skip Navigation


Europace Advance Access originally published online on August 4, 2009
Europace 2009 11(10):1281-1288; doi:10.1093/europace/eup208
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
11/10/1281    most recent
eup208v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Schmidt, B.
Right arrow Articles by Kuck, K.-H.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schmidt, B.
Right arrow Articles by Kuck, K.-H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2009. For permissions please email: journals.permissions@oxfordjournals.org.


Ablation for Atrial Fibrillation

Pulmonary vein isolation with high-intensity focused ultrasound: results from the HIFU 12F study

Boris Schmidt*, Kyoung Ryul Julian Chun, Andreas Metzner, Alexander Fuernkranz, Feifan Ouyang and Karl-Heinz Kuck

Department of Cardiology, Asklepios Klinik St. Georg, II. Med. Abteilung, Lohmühlenstr. 5, 22099 Hamburg, Germany

Aims: High-intensity focused ultrasound (HIFU) applied via a balloon catheter (BC) is a novel technology for simplified pulmonary vein isolation (PVI). Safety and efficacy of the third generation HIFU-BC were assessed.

Methods and results: In 22 patients (10 male, mean age 65 ± 6 years) with paroxysmal atrial fibrillation (PAF), a PVI during real-time PV spike registration and oesophageal temperature measurement was attempted. In 15 patients, a steerable sheath was used along with the HIFU-BC. In 67 of 83 PVs (81%), PVI was achieved exclusively using HIFU. Using the steerable sheath, the acute PVI rate rose from 50% (10/20 PVs) to 90% (57/63 PVs). In the latter, PVI was achieved with a single HIFU application in 60% (38/63 PVs) and mean sonication time of 11 ± 7 s. The mean procedure time was 166 ± 74 min including 58 ± 25 min of HIFU-BC left atrial indwelling time. In four patients, peri-procedural complications occurred (one transient ischaemic attack, one phrenic nerve palsy, and two vascular access complications). During a median follow-up of 342 days (range 272–378 days), 71% patients remained free of any AF/AT recurrence without antiarrhythmic drugs after a single procedure.

Conclusion: The novel defocused 12F HIFU-BC used in conjunction with a steerable sheath allows for very rapid PVI in patients with PAF. The enthusiasm for rapid PVI is still dampened by the potential risk of collateral damage.

Key Words: Pulmonary vein isolation, High-intensity focused ultrasound, Balloon catheter, Atrial fibrillation


* Corresponding author. Tel: +49 4018 1885 4487, Fax: +49 4018 1885 4435, Email: bor.schmidt{at}asklepios.com

Manuscript submitted 23 April 2009. Accepted after revision 8 July 2009.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.