Skip Navigation

Europace 1999 1(4):275-279; doi:10.1053/eupc.1999.0058
© 1999 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (4)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Li, Y.-G.
Right arrow Articles by Hohnloser, S.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Li, Y.-G.
Right arrow Articles by Hohnloser, S.H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


EXTENDED CASE REPORT

Atrial flutter in the recipient atrium induced by premature beats arising from the donor atrium 10 years after orthotopic heart transplantation

Y.-G. Li, B. Bender, G. Grönefeld and S.H. Hohnloser

Department of Internal Medicine, Division of Cardiology, J.W. Goethe University Frankfurt, Germany

BACKGROUND: Several mechanisms for the genesis of supraventricular arrhythmias in patients after orthotopic heart transplantation have been reported.

METHODS AND RESULTS: We describe a 58-year-old male patient in whom atrial flutter occurred 10 years after orthotopic heart transplantation. During an electrophysiological study, bidirectional conduction between the recipient and donor atria was found. Atrial flutter in the recipient atrium was induced by programmed stimulation of the donor atrium using a single extrastimulus. The clinical symptoms were caused by atrial flutter arising from the recipient atrium with 1:1 to 3:1 conduction to the donor atrium. Mapping the anastomosis between the two atria indicated fragmented potentials at a discrete site of conduction. Delivery of radiofrequency energy at this site terminated conduction in both directions. Subsequent atrial pacing of the donor and recipient atria, respectively, demonstrated bidirectional conduction block.

CONCLUSION: Symptomatic arrhythmias in patients after heart transplantation can indirectly originate from the donor atrium via bidirectional recipient–donor atrial conduction. This type of arrhythmia can be successfully treated with radiofrequency ablation.

Key Words: Atrial flutter, heart transplantation, radiofrequency catheter ablation


Correspondence: Stefan H. Hohnloser, MD, J.W. Goethe University, Department of Medicine, Division of Cardiology, Theodor Stern Kai 7, 60590 Frankfurt, Germany.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.