Skip Navigation

Europace 1999 1(2):113-120; doi:10.1053/eupc.1998.0026
© 1999 by European Society of Cardiology
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (28)
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Nielsen, J.C.
Right arrow Articles by Andersen, H.R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nielsen, J.C.
Right arrow Articles by Andersen, H.R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Programming a fixed long atrioventricular delay is not effective in preventing ventricular pacing in patients with sick sinus syndrome

J.C. Nielsen, A.K. Pedersen, P.T. Mortensen and H.R. Andersen

Department of Cardiology, Skejby University Hospital Brendstrupgaardsvej, Aarhus, Denmark

AIM: Most patients with sick sinus syndrome (SSS) and normal atrioventricular (AV) conduction receive dual chamber (DDDR) pacemakers. Programming a long AV delay has been proposed to avoid ventricular pacing. The present study aimed to evaluate ventricular stimulation in SSS patients with DDDR pacemakers with a long AV delay.

METHODS AND RESULTS: Thirty eight patients treated with DDDR pacemakers with a fixed long AV delay (300 ms) were studied. Data from the pacemaker event recorder were retrieved after 3 months and every year after implantation. Ten patients underwent 24 h Holter recording. Mean follow-up was 11·9±8·3 months. Median daily number of paced events in the ventricle was 2659 (25th–75th percentiles: 775–21 315) with a large inter-individual variation. The proportion of paced events in the ventricle correlated weakly with the baseline PQ interval (Spearman’s {rho}0·331, P=0·043). In 12/38 patients the mean daily number of paced events in the ventricle exceeded 10 000. During 24 h Holter recording, pacemaker arrhythmias caused by repetitive retrograde atrioventricular conduction, known as VA (ventriculoatrial) conduction, occurred in five out of 10 patients.

CONCLUSION: DDDR pacing with a fixed long AV delay is inefficient in reducing ventricular pacing in one third of patients and is associated with a high risk of arrhythmias caused by repetitive retrograde AV conduction, and therefore cannot be recommended for general use in SSS patients. |P[s8a|P](Europace 1999; 1: 113–120)

Key Words: AV delay, sick sinus syndrome, pacing, DDD, event recording, follow-up, pacemaker syndrome


*Correspondence: Henning Rud Andersen, MD, DMSc, Department of Cardiology, Skejby University Hospital, Brendstrupgaardsvej, 8200 Aarhus N. Denmark.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
EuropaceHome page
E. N. Simantirakis, E. G. Arkolaki, and P. E. Vardas
Novel pacing algorithms: do they represent a beneficial proposition for patients, physicians, and the health care system?
Europace, October 1, 2009; 11(10): 1272 - 1280.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, D. L. Hayes, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
J. Am. Coll. Cardiol., May 27, 2008; 51(21): e1 - e62.
[Full Text] [PDF]


Home page
CirculationHome page
Writing Committee Members, A. E. Epstein, J. P. DiMarco, K. A. Ellenbogen, N.A. M. Estes III, R. A. Freedman, L. S. Gettes, A. M. Gillinov, G. Gregoratos, S. C. Hammill, et al.
ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons
Circulation, May 27, 2008; 117(21): e350 - e408.
[Full Text] [PDF]


Home page
EuropaceHome page
A. Quesada, G. Botto, A. Erdogan, M. Kozak, P. Lercher, J. C. Nielsen, O. Piot, R. Ricci, C. Weiss, D. Becker, et al.
Managed ventricular pacing vs. conventional dual-chamber pacing for elective replacements: the PreFER MVP study: clinical background, rationale, and design
Europace, March 1, 2008; 10(3): 321 - 326.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
N. C. Wang, R. Passman, J. J. Goldberger, M. O. Sweeney, and G. A. Lamas
Minimizing Ventricular Pacing in Sinus-Node Disease
N. Engl. J. Med., December 27, 2007; 357(26): 2733 - 2734.
[Full Text] [PDF]


Home page
CirculationHome page
M. H. Schoenfeld
Contemporary Pacemaker and Defibrillator Device Therapy: Challenges Confronting the General Cardiologist
Circulation, February 6, 2007; 115(5): 638 - 653.
[Full Text] [PDF]


Home page
EuropaceHome page
G. Frohlig, D. Gras, J. Victor, P. Mabo, D. Galley, A. Savoure, G. Jauvert, P. Defaye, P. Ducloux, and A. Amblard
Use of a new cardiac pacing mode designed to eliminate unnecessary ventricular pacing.
Europace, February 1, 2006; 8(2): 96 - 101.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. O. Sweeney and F. W. Prinzen
A New Paradigm for Physiologic Ventricular Pacing
J. Am. Coll. Cardiol., January 17, 2006; 47(2): 282 - 288.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. Nahlawi, M. Waligora, S. M. Spies, R. O. Bonow, A. H. Kadish, and J. J. Goldberger
Left ventricular function during and after right ventricular pacing
J. Am. Coll. Cardiol., November 2, 2004; 44(9): 1883 - 1888.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
H. Masumoto, Y. Ueda, R. Kato, A. Usui, T. Maseki, Y. Takagi, and M. Usui
Long-term clinical performance of AAI pacing in patients with sick sinus syndrome: a comparison with dual-chamber pacing
Europace, January 1, 2004; 6(5): 444 - 450.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
J. C. Nielsen, L. Kristensen, H. R. Andersen, P. T. Mortensen, O. L. Pedersen, and A. K. Pedersen
A randomized comparison ofatrial and dual-chamber pacing in177 consecutive patients with sick sinus syndrome: Echocardiographic and clinical outcome
J. Am. Coll. Cardiol., August 20, 2003; 42(4): 614 - 623.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. S. Barold
Adverse effects of ventricular desynchronization induced by long-term right ventricular pacing
J. Am. Coll. Cardiol., August 20, 2003; 42(4): 624 - 626.
[Full Text] [PDF]


Home page
EuropaceHome page
D. E. Maurer, B. Naegeli, E. Straumann, O. Bertel, and J. Frielingsdorf
Quality of life and exercise capacity in patients with prolonged PQ interval and dual chamber pacemakers: a randomized comparison of permanent ventricular stimulation vs intrinsic AV conduction
Europace, January 1, 2003; 5(4): 411 - 417.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
M. Santini and R. Ricci
Atrial fibrillation and heart failure
Europace, January 1, 2003; 5(s1): S55 - S59.
[Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.